13 research outputs found
Quantum confined electronic states in atomically well-defined graphene nanostructures
Despite the enormous interest in the properties of graphene and the potential
of graphene nanostructures in electronic applications, the study of quantum
confined states in atomically well-defined graphene nanostructures remains an
experimental challenge. Here, we study graphene quantum dots (GQDs) with
well-defined edges in the zigzag direction, grown by chemical vapor deposition
(CVD) on an iridium(111) substrate, by low-temperature scanning tunneling
microscopy (STM) and spectroscopy (STS). We measure the atomic structure and
local density of states (LDOS) of individual GQDs as a function of their size
and shape in the range from a couple of nanometers up to ca. 20 nm. The results
can be quantitatively modeled by a relativistic wave equation and atomistic
tight-binding calculations. The observed states are analogous to the solutions
of the text book "particle-in-a-box" problem applied to relativistic massless
fermions.Comment: accepted for publication in Phys. Rev. Let
Polymer-coated bioactive glass S53P4 increases VEGF and TNF expression in an induced membrane model in vivo
The two-stage induced-membrane technique for treatment of large bone defects has become popular among orthopedic surgeons. In the first operation, the bone defect is filled with poly(methyl methacrylate) (PMMA), which is intended to produce a membrane around the implant. In the second operation, PMMA is replaced with autograft or allograft bone. Bioactive glasses (BAGs) are bone substitutes with bone-stimulating and angiogenetic properties. The aim of our study was to evaluate the inductive vascular capacity of BAG-S53P4 and poly(lactide-co-glycolide) (PLGA)-coated BAG-S53P4 for potential use as bone substitutes in a single-stage induced-membrane technique. Sintered porous rods of BAG-S53P4, PLGA-coated BAG-S53P4 and PMMA were implanted in the femur of 36 rabbits for 2, 4 and 8 weeks. The expression of vascular endothelial growth factor (VEGF) and tumor necrosis factor alpha (TNF) in the induced membranes of implanted materials was analyzed with real-time quantitative polymerase chain reaction and compared with histology. Both uncoated BAG-S53P4 and PLGA-coated BAG-S53P4 increase expression of VEGF and TNF, resulting in higher amounts of capillary beds, compared with the lower expression of VEGF and less capillary beads observed for negative control and PMMA samples. A significantly higher expression of VEGF was observed for PLGA-coated BAG-S53P4 than for PMMA at 8 weeks (p <0.036). VEGF and TNF expression in the induced membrane of BAG-S53P4 and PLGA-coated BAG-S53P4 is equal or superior to PMMA, the "gold standard" material used in the induced-membrane technique. Furthermore, the VEGF and TNF expression for PLGA-coated BAG-S53P4 increased during follow-up.Peer reviewe
S53P4 bioactive glass scaffolds induce BMP expression and integrative bone formation in a critical-sized diaphysis defect treated with a single-stage d induce d membrane technique
Surgical management of critical-sized diaphyseal defects involves multiple challenges, and up to 10% result in delayed or non-union. The two-staged induced membrane technique is successfully used to treat these defects, but it is limited by the need of several procedures and bone graft. Repeated procedures increase costs and morbidity, while grafts are subject to donor-site complications and scarce availability. To transform this two-staged technique into one graft-independent procedure, we developed amorphous porous scaffolds sintered from the clinically used bioactive glass S53P4. This work constitutes the first evaluation of such scaffolds in vivo in a critical-sized diaphyseal defect in the weight-bearing rabbit femur. We provide important knowledge and prospects for future development of sintered S53P4 scaffolds as a bone substitute. Critical-sized diaphysis defects are complicated by inherent sub-optimal healing conditions. The two staged induced membrane technique has been used to treat these challenging defects since the 1980 & rsquo;s. It involves temporary implantation of a membrane-inducing spacer and subsequent bone graft defect filling. A single-staged, graft-independent technique would reduce both socio-economic costs and patient morbidity. Our aim was to enable such single-staged approach through development of a strong bioactive glass scaffold that could replace both the spacer and the graft filling. We constructed amorphous porous scaffolds of the clinically used bioactive glass S53P4 and evaluated them in vivo using a critical sized defect model in the weight-bearing femur diaphysis of New Zealand White rabbits. S53P4 scaffolds and standard polymethylmethacrylate spacers were implanted for 2, 4, and 8 weeks. Induced membranes were confirmed histologically, and their osteostimulative activity was evaluated through RT-qPCR of bone morphogenic protein 2, 4, and 7 (BMPs). Bone formation and osseointegration were examined using histology, scanning electron microscopy, energy-dispersive X-ray analysis, and micro-computed tomography imaging. Scaffold integration, defect union and osteosynthesis were assessed manually and with X-ray projections. We demonstrated that S53P4 scaffolds induce osteostimulative membranes and produce osseointegrative new bone formation throughout the scaffolds. We also demonstrated successful stable scaffold integration with early defect union at 8 weeks postoperative in critical-sized segmental diaphyseal defects with implanted sintered amorphous S53P4 scaffolds. This study presents important considerations for future research and the potential of the S53P4 bioactive glass as a bone substitute in large diaphyseal defects. Statement of significance Surgical management of critical-sized diaphyseal defects involves multiple challenges, and up to 10% result in delayed or non-union. The two-staged induced membrane technique is successfully used to treat these defects, but it is limited by the need of several procedures and bone graft. Repeated procedures increase costs and morbidity, while grafts are subject to donor-site complications and scarce availability. To transform this two-staged technique into one graft-independent procedure, we developed amorphous porous scaffolds sintered from the clinically used bioactive glass S53P4. This work constitutes the first evaluation of such scaffolds in vivo in a critical-sized diaphyseal defect in the weight-bearing rabbit femur. We provide important knowledge and prospects for future development of sintered S53P4 scaffolds as a bone substitute. (c) 2021 The Author(s). Published by Elsevier Ltd on behalf of Acta Materialia Inc. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )Peer reviewe
S53P4 bioactive glass scaffolds induce BMP expression and integrative bone formation in a critical-sized diaphysis defect treated with a single-staged induced membrane technique
Surgical management of critical-sized diaphyseal defects involves multiple challenges, and up to 10% result in delayed or non-union. The two-staged induced membrane technique is successfully used to treat these defects, but it is limited by the need of several procedures and bone graft. Repeated procedures increase costs and morbidity, while grafts are subject to donor-site complications and scarce availability. To transform this two-staged technique into one graft-independent procedure, we developed amorphous porous scaffolds sintered from the clinically used bioactive glass S53P4. This work constitutes the first evaluation of such scaffolds in vivo in a critical-sized diaphyseal defect in the weight-bearing rabbit femur. We provide important knowledge and prospects for future development of sintered S53P4 scaffolds as a bone substitute. Critical-sized diaphysis defects are complicated by inherent sub-optimal healing conditions. The two staged induced membrane technique has been used to treat these challenging defects since the 1980 & rsquo;s. It involves temporary implantation of a membrane-inducing spacer and subsequent bone graft defect filling. A single-staged, graft-independent technique would reduce both socio-economic costs and patient morbidity. Our aim was to enable such single-staged approach through development of a strong bioactive glass scaffold that could replace both the spacer and the graft filling. We constructed amorphous porous scaffolds of the clinically used bioactive glass S53P4 and evaluated them in vivo using a critical sized defect model in the weight-bearing femur diaphysis of New Zealand White rabbits. S53P4 scaffolds and standard polymethylmethacrylate spacers were implanted for 2, 4, and 8 weeks. Induced membranes were confirmed histologically, and their osteostimulative activity was evaluated through RT-qPCR of bone morphogenic protein 2, 4, and 7 (BMPs). Bone formation and osseointegration were examined using histology, scanning electron microscopy, energy-dispersive X-ray analysis, and micro-computed tomography imaging. Scaffold integration, defect union and osteosynthesis were assessed manually and with X-ray projections. We demonstrated that S53P4 scaffolds induce osteostimulative membranes and produce osseointegrative new bone formation throughout the scaffolds. We also demonstrated successful stable scaffold integration with early defect union at 8 weeks postoperative in critical-sized segmental diaphyseal defects with implanted sintered amorphous S53P4 scaffolds. This study presents important considerations for future research and the potential of the S53P4 bioactive glass as a bone substitute in large diaphyseal defects. Statement of significance Surgical management of critical-sized diaphyseal defects involves multiple challenges, and up to 10% result in delayed or non-union. The two-staged induced membrane technique is successfully used to treat these defects, but it is limited by the need of several procedures and bone graft. Repeated procedures increase costs and morbidity, while grafts are subject to donor-site complications and scarce availability. To transform this two-staged technique into one graft-independent procedure, we developed amorphous porous scaffolds sintered from the clinically used bioactive glass S53P4. This work constitutes the first evaluation of such scaffolds in vivo in a critical-sized diaphyseal defect in the weight-bearing rabbit femur. We provide important knowledge and prospects for future development of sintered S53P4 scaffolds as a bone substitute. (c) 2021 The Author(s). Published by Elsevier Ltd on behalf of Acta Materialia Inc. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )Peer reviewe
Effects of ship emissions on air quality in the Baltic Sea region simulated with three different chemistry transport models
The Baltic Sea is a highly frequented shipping area with busy shipping lanes close to
densely populated regions. Exhaust emissions from ship traffic into the atmosphere
do not only enhance air pollution, they also affect the Baltic Sea environment
through acidification and eutrophication of marine waters and surrounding terrestrial
ecosystems. As part of the European BONUS project SHEBA (Sustainable Shipping and
Environment of the Baltic Sea region), the transport, chemical transformation and fate
of atmospheric pollutants in the Baltic Sea region were simulated with three regional
chemistry transport model (CTM) systems, CMAQ, EMEP/MSC-W and SILAM, with grid
resolutions between 4 and 11 km. The main goal was to quantify
the effect that shipping emissions have on the regional air quality in the Baltic Sea
region when the same shipping emission dataset but different CTMs are used in their typical
set-ups. The performance of these models and the shipping contribution to
the results of the individual models were evaluated for sulfur dioxide (SO2),
nitrogen dioxide (NO2), ozone (O3) and particulate matter
(PM2.5). Model results from the three CTMs for total air pollutant concentrations
were compared to observations
from rural and urban background stations of the AirBase monitoring network in the
coastal areas of the Baltic Sea region. Observed PM2.5
in summer was underestimated strongly by CMAQ and to some extent by EMEP/MSC-W.
Observed PM2.5 in winter was underestimated by SILAM.
In autumn all models were in better agreement with observed PM2.5.
The spatial average of the annual mean O3 in the EMEP/MSC-W simulation
was ca. 20 %
higher compared to the other two simulations, which is mainly the
consequence of using a different set of boundary conditions for the European model
domain. There are significant differences in the calculated ship contributions to the
levels of air pollutants among the three models.
EMEP/MSC-W, with the coarsest grid, predicted weaker ozone depletion through NO
emissions in the proximity of the main shipping routes than the other two models.
The average contribution of ships to PM2.5 levels in coastal land areas is
in the range of 3.1 %–5.7 % for the three CTMs.
Differences in ship-related PM2.5 between the models are mainly attributed
to differences in the schemes for inorganic aerosol formation.
Differences in the ship-related elemental carbon (EC) among the CTMs can be
explained by differences in the meteorological conditions, atmospheric transport
processes and the applied wet-scavenging parameterizations.
Overall, results from the
present study show the sensitivity of the ship contribution to combined uncertainties
in boundary conditions, meteorological data and aerosol formation and deposition schemes.
This is an important step towards a more reliable evaluation of policy options regarding emission
regulations for ship traffic and the planned introduction of a nitrogen emission control
area (NECA) in the Baltic Sea and the North Sea in 2021.</p
SINTERED S53P4 BIOACTIVE GLASS SCAFFOLDS HAVE ANTI-INFLAMMATORY PROPERTIES AND STIMULATE OSTEOGENESIS IN VITRO
Bioactive glasses (BAG) are used as bone-graft substitutes in orthopaedic surgery. A specific BAG scaffold was developed by sintering BAG-S53P4 granules. It is hypothesised that this scaffold can be used as a bone substitute to fill bone defects and induce a bioactive membrane (IM) around the defect site. Beyond providing the scaffold increased mechanical strength, that the initial inflammatory reaction and subsequent IM formation can be enhanced by coating the scaffolds with poly(DL-lactide-co-glycolide) (PLGA) is also hypothesised. To study the immunomodulatory effects, BAG-S53P4 (+/- PLGA) scaffolds were placed on monolayers of primary human macrophage cultures and the production of various pro- and anti-inflammatory cytokines was assessed using reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) and ELISA. To study the osteogenic effects, BAG-S53P4 (+/- PLGA) scaffolds were cultured with rabbit mesenchymal stem cells and osteogenic differentiation was evaluated by RT-qPCR and matrix mineralisation assays. The scaffold ion release was quantified and the BAG surface reactivity visualised. Furthermore, the pH of culture media was measured. BAG-S53P4 scaffolds had both anti-inflammatory and osteogenic properties that were likely attributable to alkalinisation of the media and ion release from the scaffold. pH change, ion release, and immunomodulatory properties of the scaffold could be modulated by the PLGA coating. Contrary to the hypothesis, the coating functioned by attenuating the BAG surface reactions and subsequent anti-inflammatory properties, rather than inducing an elevated inflammatory response compared to BAG-S53P4 alone. These results further validated the use of BAG-S53P4 (+/- PLGA) scaffolds as bone substitutes and indicate that scaffold properties can be tailored to a specific clinical need.Peer reviewe
Electronic states in finite graphene nanoribbons: Effect of charging and defects
We study the electronic structure of finite armchair graphene nanoribbons using density-functional theory and the Hubbard model, concentrating on the states localized at the zigzag termini. We show that the energy gaps between end-localized states are sensitive to doping, and that in doped systems, the gap between the end-localized states decreases exponentially as a function of the ribbon length. Doping also quenches the antiferromagnetic coupling between the end-localized states leading to a spin-split gap in neutral ribbons. By comparing dI/dV maps calculated using the many-body Hubbard model, its mean-field approximation and density-functional theory, we show that the use of a single-particle description is justified for graphene π states in case spin properties are not the main interest. Furthermore, we study the effect of structural defects in the ribbons on their electronic structure. Defects at one ribbon terminus do not significantly modify the electronic states localized at the intact end. This provides further evidence for the interpretation of a multipeak structure in a recent scanning tunneling spectroscopy (STS) experiment resulting from inelastic tunneling processes [van der Lit et al., Nat. Commun. 4, 2023 (2013)]. Finally, we show that the hydrogen termination at the flake edges leaves identifiable fingerprints on the positive bias side of STS measurements, thus possibly aiding the experimental identification of graphene structures.Peer reviewe
Suppression of electron-vibron coupling in graphene nanoribbons contacted via a single atom
Graphene nanostructures, where quantum confinement opens an energy gap in the band structure, hold promise for future electronic devices. To realize the full potential of these materials, atomic-scale control over the contacts to graphene and the graphene nanostructure forming the active part of the device is required. The contacts should have a high transmission and yet not modify the electronic properties of the active region significantly to maintain the potentially exciting physics offered by the nanoscale honeycomb lattice. Here we show how contacting an atomically well-defined graphene nanoribbon to a metallic lead by a chemical bond via only one atom significantly influences the charge transport through the graphene nanoribbon but does not affect its electronic structure. Specifically, we find that creating well-defined contacts can suppress inelastic transport channels.Peer reviewe