18 research outputs found

    Measuring mechanical motion with a single spin

    Get PDF
    We study theoretically the measurement of a mechanical oscillator using a single two level system as a detector. In a recent experiment, we used a single electronic spin associated with a nitrogen vacancy center in diamond to probe the thermal motion of a magnetized cantilever at room temperature {Kolkowitz et al., Science 335, 1603 (2012)}. Here, we present a detailed analysis of the sensitivity limits of this technique, as well as the possibility to measure the zero point motion of the oscillator. Further, we discuss the issue of measurement backaction in sequential measurements and find that although backaction heating can occur, it does not prohibit the detection of zero point motion. Throughout the paper we focus on the experimental implementation of a nitrogen vacancy center coupled to a magnetic cantilever; however, our results are applicable to a wide class of spin-oscillator systems. Implications for preparation of nonclassical states of a mechanical oscillator are also discussed.Comment: 17 pages, 6 figure

    Measuring nanomechanical motion with an imprecision far below the standard quantum limit

    Full text link
    We demonstrate a transducer of nanomechanical motion based on cavity enhanced optical near-fields capable of achieving a shot-noise limited imprecision more than 10 dB below the standard quantum limit (SQL). Residual background due to fundamental thermodynamical frequency fluctuations allows a total imprecision 3 dB below the SQL at room temperature (corresponding to 600 am/Hz^(1/2) in absolute units) and is known to reduce to negligible values for moderate cryogenic temperatures. The transducer operates deeply in the quantum backaction dominated regime, prerequisite for exploring quantum backaction, measurement-induced squeezing and accessing sub-SQL sensitivity using backaction evading techniques

    Capacitive Spring Softening in Single-Walled Carbon Nanotube Nanoelectromechanical Resonators

    Full text link
    We report the capacitive spring softening effect observed in single-walled carbon nanotube (SWNT) nanoelectromechanical (NEM) resonators. The nanotube resonators adopt dual-gate configuration with both bottom-gate and side-gate capable of tuning the resonance frequency through capacitive coupling. Interestingly, downward resonance frequency shifting is observed with increasing side-gate voltage, which can be attributed to the capacitive softening of spring constant. Furthermore, in-plane vibrational modes exhibit much stronger spring softening effect than out-of-plan modes. Our dual-gate design should enable the differentiation between these two types of vibrational modes, and open up new possibility for nonlinear operation of nanotube resonators.Comment: 12 pages/ 3 figure
    corecore