914 research outputs found

    Feedback-free optical cavity with self-resonating mechanism

    Full text link
    We demonstrated the operation of a high finesse optical cavity without utilizing an active feedback system to stabilize the resonance. The effective finesse, which is a finesse including the overall system performance, of the cavity was measured to be 394,000±10,000394,000 \pm 10,000, and the laser power stored in the cavity was 2.52±0.132.52 \pm 0.13 kW, which is approximately 187,000 times greater than the incident power to the cavity. The stored power was stabilized with a fluctuation of 1.7%1.7 \%, and we confirmed continuous cavity operation for more than two hours. This result has the potential to trigger an innovative evolution for applications that use optical resonant cavities such as compact photon sources with laser-Compton scattering or cavity enhanced absorption spectroscopy.Comment: 5 pages, 7 figure

    Comparison of lens- and fiber-coupled CCD detectors for X-ray computed tomography

    Get PDF
    Lens- and fiber-coupled X-ray detectors with identical CCD chips were compared in their performance in high-resolution computed tomography experiments

    Development of an intense positron source using a crystal--amorphous hybrid target for linear colliders

    Full text link
    In a conventional positron source driven by a few GeV electron beam, a high amount of heat is loaded into a positron converter target to generate intense positrons required by linear colliders, and which would eventually damage the converter target. A hybrid target, composed of a single crystal target as a radiator of intense gamma--rays, and an amorphous converter target placed downstream of the crystal, was proposed as a scheme which could overcome the problem.This paper describes the development of an intense positron source with the hybrid target. A series of experiments on positron generation with the hybrid target has been carried out with a 8--GeV electron beam at the KEKB linac. We observed that positron yield from the hybrid target increased when the incident electron beam was aligned to the crystal axis and exceeded the one from the conventional target with the converter target of the same thickness, when its thickness is less than about 2 radiation length. The measurements in the temperature rise of the amorphous converter target was successfully carried out by use of thermocouples. These results lead to establishment to the evaluation of the hybrid target as an intense positron source.Comment: 17pages, 10figure
    • …
    corecore