695 research outputs found
Vacuum-field level shifts in a single trapped ion mediated by a single distant mirror
A distant mirror leads to a vacuum-induced level shift in a laser-excited
atom. This effect has been measured with a single mirror 25 cm away from a
single, trapped barium ion. This dispersive action is the counterpart to the
mirror's dissipative effect, which has been shown earlier to effect a change in
the ion's spontaneous decay [J. Eschner et al., Nature 413, 495-498 (2001)].
The experimental data are well described by 8-level optical Bloch equations
which are amended to take into account the presence of the mirror according to
the model in [U. Dorner and P. Zoller, Phys. Rev. A 66, 023816 (2002)].
Observed deviations from simple dispersive behavior are attributed to
multi-level effects.Comment: version accepted by PR
Calibration and performance of the photon sensor response of FACT -- The First G-APD Cherenkov telescope
The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of
the performance of silicon photo detectors in Cherenkov Astronomy. For more
than two years it is operated on La Palma, Canary Islands (Spain), for the
purpose of long-term monitoring of astrophysical sources. For this, the
performance of the photo detectors is crucial and therefore has been studied in
great detail. Special care has been taken for their temperature and voltage
dependence implementing a correction method to keep their properties stable.
Several measurements have been carried out to monitor the performance. The
measurements and their results are shown, demonstrating the stability of the
gain below the percent level. The resulting stability of the whole system is
discussed, nicely demonstrating that silicon photo detectors are perfectly
suited for the usage in Cherenkov telescopes, especially for long-term
monitoring purpose
FACT -- Operation of the First G-APD Cherenkov Telescope
Since more than two years, the First G-APD Cherenkov Telescope (FACT) is
operating successfully at the Canary Island of La Palma. Apart from its purpose
to serve as a monitoring facility for the brightest TeV blazars, it was built
as a major step to establish solid state photon counters as detectors in
Cherenkov astronomy.
The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode
avalanche photo diodes (G-APD aka. MPPC or SiPM) for photon detection. Since
properties as the gain of G-APDs depend on temperature and the applied voltage,
a real-time feedback system has been developed and implemented. To correct for
the change introduced by temperature, several sensors have been placed close to
the photon detectors. Their read out is used to calculate a corresponding
voltage offset. In addition to temperature changes, changing current introduces
a voltage drop in the supporting resistor network. To correct changes in the
voltage drop introduced by varying photon flux from the night-sky background,
the current is measured and the voltage drop calculated. To check the stability
of the G-APD properties, dark count spectra with high statistics have been
taken under different environmental conditions and been evaluated.
The maximum data rate delivered by the camera is about 240 MB/s. The recorded
data, which can exceed 1 TB in a moonless night, is compressed in real-time
with a proprietary loss-less algorithm. The performance is better than gzip by
almost a factor of two in compression ratio and speed. In total, two to three
CPU cores are needed for data taking. In parallel, a quick-look analysis of the
recently recorded data is executed on a second machine. Its result is publicly
available within a few minutes after the data were taken.
[...]Comment: 19th IEEE Real-Time Conference, Nara, Japan (2014
FACT -- the First Cherenkov Telescope using a G-APD Camera for TeV Gamma-ray Astronomy (HEAD 2010)
Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly
improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are
currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing
an old IACT with a mirror area of 9.5 square meters and construct a new, fine
pixelized camera using novel G-APDs. The main goal is to evaluate the
performance of a complete system by observing very high energy gamma-rays from
the Crab Nebula. This is an important field test to check the feasibility of
G-APD-based cameras to replace at some time the PMT-based cameras of planned
future IACTs like AGIS and CTA. In this article, we present the basic design of
such a camera as well as some important details to be taken into account.Comment: Poster shown at HEAD 2010, Big Island, Hawaii, March 1-4, 201
A novel camera type for very high energy gamma-ray astronomy based on Geiger-mode avalanche photodiodes
Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light
detection in atmospheric Cherenkov telescopes. In this paper, the design and
commissioning of a 36-pixel G-APD prototype camera is presented. The data
acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond
time resolution has been achieved. Cosmic-ray induced air showers have been
recorded using an imaging mirror setup, in a self-triggered mode. This is the
first time that such measurements have been carried out with a complete G-APD
camera.Comment: 9 pages with 11 figure
FACT -- The G-APD revolution in Cherenkov astronomy
Since two years, the FACT telescope is operating on the Canary Island of La
Palma. Apart from its purpose to serve as a monitoring facility for the
brightest TeV blazars, it was built as a major step to establish solid state
photon counters as detectors in Cherenkov astronomy. The camera of the First
G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes
(G-APD), equipped with solid light guides to increase the effective light
collection area of each sensor. Since no sense-line is available, a special
challenge is to keep the applied voltage stable although the current drawn by
the G-APD depends on the flux of night-sky background photons significantly
varying with ambient light conditions. Methods have been developed to keep the
temperature and voltage dependent response of the G-APDs stable during
operation. As a cross-check, dark count spectra with high statistics have been
taken under different environmental conditions. In this presentation, the
project, the developed methods and the experience from two years of operation
of the first G-APD based camera in Cherenkov astronomy under changing
environmental conditions will be presented.Comment: Proceedings of the Nuclear Science Symposium and Medical Imaging
Conference (IEEE-NSS/MIC), 201
FACT - The First G-APD Cherenkov Telescope: Status and Results
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the
HEGRA CT3 telescope, still located at the Observatorio del Roque de los
Muchachos, and it is successfully in operation since Oct. 2011. The use of
Silicon devices promises a higher photon detection efficiency, more robustness
and higher precision than photo-multiplier tubes. The FACT collaboration is
investigating with which precision these devices can be operated on the
long-term. Currently, the telescope is successfully operated from remote and
robotic operation is under development. During the past months of operation,
the foreseen monitoring program of the brightest known TeV blazars has been
carried out, and first physics results have been obtained including a strong
flare of Mrk501. An instantaneous flare alert system is already in a testing
phase. This presentation will give an overview of the project and summarize its
goals, status and first results
Probing the quantum vacuum with an artificial atom in front of a mirror
Quantum fluctuations of the vacuum are both a surprising and fundamental
phenomenon of nature. Understood as virtual photons flitting in and out of
existence, they still have a very real impact, \emph{e.g.}, in the Casimir
effects and the lifetimes of atoms. Engineering vacuum fluctuations is
therefore becoming increasingly important to emerging technologies. Here, we
shape vacuum fluctuations using a "mirror", creating regions in space where
they are suppressed. As we then effectively move an artificial atom in and out
of these regions, measuring the atomic lifetime tells us the strength of the
fluctuations. The weakest fluctuation strength we observe is 0.02 quanta, a
factor of 50 below what would be expected without the mirror, demonstrating
that we can hide the atom from the vacuum
Limits to dark matter annihilation cross-section from a combined analysis of MAGIC and Fermi-LAT observations of dwarf satellite galaxies
We present the first joint analysis of gamma-ray data from the MAGIC
Cherenkov telescopes and the Fermi Large Area Telescope (LAT) to search for
gamma-ray signals from dark matter annihilation in dwarf satellite galaxies. We
combine 158 hours of Segue 1 observations with MAGIC with 6-year observations
of 15 dwarf satellite galaxies by the Fermi-LAT. We obtain limits on the
annihilation cross-section for dark matter particle masses between 10 GeV and
100 TeV - the widest mass range ever explored by a single gamma-ray analysis.
These limits improve on previously published Fermi-LAT and MAGIC results by up
to a factor of two at certain masses. Our new inclusive analysis approach is
completely generic and can be used to perform a global, sensitivity-optimized
dark matter search by combining data from present and future gamma-ray and
neutrino detectors.Comment: 19 pages, 3 figures. V2: Few typos corrected and references added.
Matches published version JCAP 02 (2016) 03
- …