27 research outputs found

    Motoneuron membrane potentials follow a time inhomogeneous jump diffusion process

    Get PDF
    Stochastic leaky integrate-and-fire models are popular due to their simplicity and statistical tractability. They have been widely applied to gain understanding of the underlying mechanisms for spike timing in neurons, and have served as building blocks for more elaborate models. Especially the Ornstein–Uhlenbeck process is popular to describe the stochastic fluctuations in the membrane potential of a neuron, but also other models like the square-root model or models with a non-linear drift are sometimes applied. Data that can be described by such models have to be stationary and thus, the simple models can only be applied over short time windows. However, experimental data show varying time constants, state dependent noise, a graded firing threshold and time-inhomogeneous input. In the present study we build a jump diffusion model that incorporates these features, and introduce a firing mechanism with a state dependent intensity. In addition, we suggest statistical methods to estimate all unknown quantities and apply these to analyze turtle motoneuron membrane potentials. Finally, simulated and real data are compared and discussed. We find that a square-root diffusion describes the data much better than an Ornstein–Uhlenbeck process with constant diffusion coefficient. Further, the membrane time constant decreases with increasing depolarization, as expected from the increase in synaptic conductance. The network activity, which the neuron is exposed to, can be reasonably estimated to be a threshold version of the nerve output from the network. Moreover, the spiking characteristics are well described by a Poisson spike train with an intensity depending exponentially on the membrane potential

    Terlipressin versus norepinephrine to counteract anesthesia-induced hypotension in patients treated with renin-angiotensin system inhibitors: effects on systemic and regional hemodynamics.

    No full text
    Background: Terlipressin has been suggested as the ideal drug to treat anesthesia-induced hypotension in patients under long-term renin-angiotensin system inhibitor treatment for arterial hypertension. The authors compared the effects of terlipressin and norepinephrine on systemic hemodynamic parameters and gastric mucosal perfusion using a laser Doppler flowmetry technique in patients treated with renin-angiotensin system inhibitors who experienced hypotension at induction of anesthesia. Methods: Thirty-two patients scheduled for carotid endarterectomy under general anesthesia and treated with renin-angiotensin system inhibitors had hypotension after induction of general anesthesia. They were randomized to receive 1 mg of terlipressin (n 16) or norepinephrine infusion (n 16) to counteract anesthesia-induced hypotension. A laser Doppler probe was introduced into the gastric lumen. All measurements were performed just before surgery, during hypotension, at 30 min, and at 4 h. Results: Terlipressin produced an increase in mean arterial pressure and a decrease in gastric mucosal perfusion detected by laser Doppler flowmetry (P < 0.05) over 30 min that were sustained for 4 h. During the infusion, norepinephrine produced an increase in mean arterial pressure and in gastric mucosal perfusion detected by laser Doppler flowmetry (P < 0.05). If compared to norepinephrine, terlipressin reduced oxygen delivery and oxygen consumption (P < 0.05) and increased arterial lactate concentrations (P < 0.05). Conclusion: This study showed the efficacy of terlipressin in the treatment of hypotension episodes in anesthetized patients chronically treated with renin-angiotensin system inhibitors, angiotensin converting-enzyme inhibitors, and angiotensin II receptor antagonists. However, the negative effects on gastric mucosal perfusion and the risk of iatrogenic oxygen supply dependency of terlipressin need to be taken into account

    Terlipressin versus norepinephrine to counteract anesthesia-induced hypotension in patients treated with renin-angiotensin system inhibitors: effects on systemic and regional hemodynamics

    No full text
    Abstract BACKGROUND: Terlipressin has been suggested as the ideal drug to treat anesthesia-induced hypotension in patients under long-term renin-angiotensin system inhibitor treatment for arterial hypertension. The authors compared the effects of terlipressin and norepinephrine on systemic hemodynamic parameters and gastric mucosal perfusion using a laser Doppler flowmetry technique in patients treated with renin-angiotensin system inhibitors who experienced hypotension at induction of anesthesia. METHODS: Thirty-two patients scheduled for carotid endarterectomy under general anesthesia and treated with renin-angiotensin system inhibitors had hypotension after induction of general anesthesia. They were randomized to receive 1 mg of terlipressin (n = 16) or norepinephrine infusion (n = 16) to counteract anesthesia-induced hypotension. A laser Doppler probe was introduced into the gastric lumen. All measurements were performed just before surgery, during hypotension, at 30 min, and at 4 h. RESULTS: Terlipressin produced an increase in mean arterial pressure and a decrease in gastric mucosal perfusion detected by laser Doppler flowmetry (P < 0.05) over 30 min that were sustained for 4 h. During the infusion, norepinephrine produced an increase in mean arterial pressure and in gastric mucosal perfusion detected by laser Doppler flowmetry (P < 0.05). If compared to norepinephrine, terlipressin reduced oxygen delivery and oxygen consumption (P < 0.05) and increased arterial lactate concentrations (P < 0.05). CONCLUSION: This study showed the efficacy of terlipressin in the treatment of hypotension episodes in anesthetized patients chronically treated with renin-angiotensin system inhibitors, angiotensin converting-enzyme inhibitors, and angiotensin II receptor antagonists. However, the negative effects on gastric mucosal perfusion and the risk of iatrogenic oxygen supply dependency of terlipressin need to be taken into account
    corecore