194 research outputs found

    Production of narrowband tunable extreme-ultraviolet radiation by noncollinear resonance-enhanced four-wave mixing

    Get PDF
    Fourier-transform-limited extreme-ultraviolet (XUV) radiation (bandwidth ≲300 MHz) tunable around 91 nm is produced by use of two-photon resonance-enhanced four-wave mixing on the Kr resonance at 94 093 c

    Structural and thermodynamic characterization of the adrenodoxin-like domain of the electron-transfer protein Etp1 from Schizosaccharomyces pombe

    Get PDF
    The protein Etp1 of Schizosaccharomyces pombe consists of an amino-terminal COX15-like domain and a carboxy-terminal ferredoxin-like domain, Etp1(fd), which is cleaved off after mitochondrial import. The physiological function of Etp1(fd) is supposed to lie in the participation in the assembly of iron-sulfur clusters and the synthesis of heme A. In addition, the protein was shown to be the first microbial ferredoxin being able to support electron transfer in mitochondrial steroid hydroxylating cytochrome P450 systems in vivo and in vitro, replacing thereby the native redox partner, adrenodoxin. Despite a sequence similarity of 39% and the fact that fission yeast is a mesophilic organism, thermodynamic studies revealed that Etp1(fd) has a melting temperature more than 20°C higher than adrenodoxin. The three-dimensional structure of Etp1(fd) has been determined by crystallography. To the best of our knowledge it represents the first three-dimensional structure of a yeast ferredoxin. The structure-based sequence alignment of Etp1(fd) with adrenodoxin yields a rational explanation for their observed mutual exchangeability in the cytochrome P450 system. Analysis of the electron exchange with the S. pombe redox partner Arh1 revealed differences between Etp1(fd) and adrenodoxin, which might be linked to their different physiological functions in the mitochondria of mammals and yeast

    High-fidelity state detection and tomography of a single ion Zeeman qubit

    Full text link
    We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr+ ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error-threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography

    Phase Synchronization in Railway Timetables

    Full text link
    Timetable construction belongs to the most important optimization problems in public transport. Finding optimal or near-optimal timetables under the subsidiary conditions of minimizing travel times and other criteria is a targeted contribution to the functioning of public transport. In addition to efficiency (given, e.g., by minimal average travel times), a significant feature of a timetable is its robustness against delay propagation. Here we study the balance of efficiency and robustness in long-distance railway timetables (in particular the current long-distance railway timetable in Germany) from the perspective of synchronization, exploiting the fact that a major part of the trains run nearly periodically. We find that synchronization is highest at intermediate-sized stations. We argue that this synchronization perspective opens a new avenue towards an understanding of railway timetables by representing them as spatio-temporal phase patterns. Robustness and efficiency can then be viewed as properties of this phase pattern

    Optimal estimation of qubit states with continuous time measurements

    Get PDF
    We propose an adaptive, two steps strategy, for the estimation of mixed qubit states. We show that the strategy is optimal in a local minimax sense for the trace norm distance as well as other locally quadratic figures of merit. Local minimax optimality means that given nn identical qubits, there exists no estimator which can perform better than the proposed estimator on a neighborhood of size n1/2n^{-1/2} of an arbitrary state. In particular, it is asymptotically Bayesian optimal for a large class of prior distributions. We present a physical implementation of the optimal estimation strategy based on continuous time measurements in a field that couples with the qubits. The crucial ingredient of the result is the concept of local asymptotic normality (or LAN) for qubits. This means that, for large nn, the statistical model described by nn identically prepared qubits is locally equivalent to a model with only a classical Gaussian distribution and a Gaussian state of a quantum harmonic oscillator. The term `local' refers to a shrinking neighborhood around a fixed state ρ0\rho_{0}. An essential result is that the neighborhood radius can be chosen arbitrarily close to n1/4n^{-1/4}. This allows us to use a two steps procedure by which we first localize the state within a smaller neighborhood of radius n1/2+ϵn^{-1/2+\epsilon}, and then use LAN to perform optimal estimation.Comment: 32 pages, 3 figures, to appear in Commun. Math. Phy

    Atomic transition frequencies, isotope shifts, and sensitivity to variation of the fine structure constant for studies of quasar absorption spectra

    Full text link
    Theories unifying gravity with other interactions suggest spatial and temporal variation of fundamental "constants" in the Universe. A change in the fine structure constant, alpha, could be detected via shifts in the frequencies of atomic transitions in quasar absorption systems. Recent studies using 140 absorption systems from the Keck telescope and 153 from the Very Large Telescope, suggest that alpha varies spatially. That is, in one direction on the sky alpha seems to have been smaller at the time of absorption, while in the opposite direction it seems to have been larger. To continue this study we need accurate laboratory measurements of atomic transition frequencies. The aim of this paper is to provide a compilation of transitions of importance to the search for alpha variation. They are E1 transitions to the ground state in several different atoms and ions, with wavelengths ranging from around 900 - 6000 A, and require an accuracy of better than 10^{-4} A. We discuss isotope shift measurements that are needed in order to resolve systematic effects in the study. The coefficients of sensitivity to alpha-variation (q) are also presented.Comment: Includes updated version of the "alpha line" lis

    Functional characterization of the human myosin-7a motor domain

    Get PDF
    Myosin-7a participates in auditory and visual processes. Defects in MYO7A, the gene encoding the myosin-7a heavy chain, are causative for Usher syndrome 1B, the most frequent cause of deaf-blindness in humans. In the present study, we performed a detailed kinetic and functional characterization of the isolated human myosin-7a motor domain to elucidate the details of chemomechanical coupling and the regulation of motor function. A rate-limiting, slow ADP release step causes long lifetimes of strong actin-binding intermediates and results in a high duty ratio. Moreover, our results reveal a Mg2+-sensitive regulatory mechanism tuning the kinetic and mechanical properties of the myosin-7a motor domain. We obtained direct evidence that changes in the concentration of free Mg2+ ions affect the motor properties of human myosin-7a using an in vitro motility assay system. Our results suggest that in a cellular environment, compartment-specific fluctuations in free Mg2+ ions can mediate the conditional switching of myosin-7a between cargo moving and tension bearing modes

    Thyroid function tests in patients taking thyroid medication in Germany: Results from the population-based Study of Health in Pomerania (SHIP)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Studies from iodine-sufficient areas have shown that a high proportion of patients taking medication for thyroid diseases have thyroid stimulating hormone (TSH) levels outside the reference range. Next to patient compliance, inadequate dosing adjustment resulting in under- and over-treatment of thyroid disease is a major cause of poor therapy outcomes. Using thyroid function tests, we aim to measure the proportions of subjects, who are under- or over-treated with thyroid medication in a previously iodine-deficient area.</p> <p>Findings</p> <p>Data from 266 subjects participating in the population-based Study of Health in Pomerania (SHIP) were analysed. All subjects were taking thyroid medication. Serum TSH levels were measured using immunochemiluminescent procedures. TSH levels of < 0.27 or > 2.15 mIU/L in subjects younger than 50 years and < 0.19 or > 2.09 mIU/L in subjects 50 years and older, were defined as decreased or elevated, according to the established reference range for the specific study area. Our analysis revealed that 56 of 190 (29.5%) subjects treated with thyroxine had TSH levels outside the reference range (10.0% elevated, 19.5% decreased). Of the 31 subjects taking antithyroid drugs, 12 (38.7%) had TSH levels outside the reference range (9.7% elevated, 29.0% decreased). These proportions were lower in the 45 subjects receiving iodine supplementation (2.2% elevated, 8.9% decreased). Among the 3,974 SHIP participants not taking thyroid medication, TSH levels outside the reference range (2.8% elevated, 5.9% decreased) were less frequent.</p> <p>Conclusion</p> <p>In concordance with previous studies in iodine-sufficient areas, our results indicate that a considerable number of patients taking thyroid medication are either under- or over-treated. Improved monitoring of these patients' TSH levels, compared to the local reference range, is recommended.</p
    corecore