13 research outputs found
Vacuum-assisted breast biopsy: A comparison of 11-gauge and 8-gauge needles in benign breast disease
© 2008 Hahn et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution Licens
Certification of breast centres in Germany: proof of concept for a prototypical example of quality assurance in multidisciplinary cancer care
<p>Abstract</p> <p>Background</p> <p>The main study objectives were: to develop a set of requirements of comprehensive breast centres; to establish a nationwide voluntary certification programme for breast centres based on such requirements, a certified quality management system (QMS), and scheduled independent, external audits and periodic recertification; and to demonstrate the general acceptance of such a certification programme with a view to introducing similar certification programmes for other major cancers.</p> <p>Methods</p> <p>Breast centres introduced a QMS and voluntarily participated in an external certification procedure based on guideline-derived Requirements of Breast Centres specifically developed for the application procedure, all subsequent audits and recertification. All data (numbers of pending and successful applications, sites/centre, etc.) were collected by a newly founded, independent organisation for certification of cancer services delivery. Data analysis was descriptive.</p> <p>Results</p> <p>Requirements of Breast Centres were developed by the German Cancer Society (DKG), the German Society of Senology (DGS) and other relevant specialist medical societies in the form of a questionnaire comprising 185 essential items based on evidence-based guidelines and the European Society of Breast Cancer Specialists' (EUSOMA) requirements of specialist breast units. From late 2002 to mid 2008, the number of participating breast centres rose from 1 to 175. As of mid 2008, 77% of an estimated 50,000 new breast cancers in Germany were diagnosed and treated at certified breast centres, 78% of which were single-site centres.</p> <p>Conclusion</p> <p>Nationwide voluntary certification of breast centres is feasible and well accepted in Germany. Dual certification of breast centres that involves certification of breast services to guideline-derived requirements in conjunction with independent certification of a mandatory QMS can serve as a model for other multidisciplinary site-specific cancer centres.</p
Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach
<p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p
BI-RADS ® for Ultrasound - Positive and Negative Predictive Values of sonographic features of the breast
M. A. Collins' Foster steam traction engine No.13052 'Clara' photographed at Nelson Fair, 21 July 1936. Digitisation and record funded by the Pilgrim Trust