237 research outputs found
Fall Prediction and Prevention Systems: Recent Trends, Challenges, and Future Research Directions.
Fall prediction is a multifaceted problem that involves complex interactions between physiological, behavioral, and environmental factors. Existing fall detection and prediction systems mainly focus on physiological factors such as gait, vision, and cognition, and do not address the multifactorial nature of falls. In addition, these systems lack efficient user interfaces and feedback for preventing future falls. Recent advances in internet of things (IoT) and mobile technologies offer ample opportunities for integrating contextual information about patient behavior and environment along with physiological health data for predicting falls. This article reviews the state-of-the-art in fall detection and prediction systems. It also describes the challenges, limitations, and future directions in the design and implementation of effective fall prediction and prevention systems
Assessing the feasibility of online SSVEP decoding in human walking using a consumer EEG headset.
BackgroundBridging the gap between laboratory brain-computer interface (BCI) demonstrations and real-life applications has gained increasing attention nowadays in translational neuroscience. An urgent need is to explore the feasibility of using a low-cost, ease-of-use electroencephalogram (EEG) headset for monitoring individuals' EEG signals in their natural head/body positions and movements. This study aimed to assess the feasibility of using a consumer-level EEG headset to realize an online steady-state visual-evoked potential (SSVEP)-based BCI during human walking.MethodsThis study adopted a 14-channel Emotiv EEG headset to implement a four-target online SSVEP decoding system, and included treadmill walking at the speeds of 0.45, 0.89, and 1.34 meters per second (m/s) to initiate the walking locomotion. Seventeen participants were instructed to perform the online BCI tasks while standing or walking on the treadmill. To maintain a constant viewing distance to the visual targets, participants held the hand-grip of the treadmill during the experiment. Along with online BCI performance, the concurrent SSVEP signals were recorded for offline assessment.ResultsDespite walking-related attenuation of SSVEPs, the online BCI obtained an information transfer rate (ITR) over 12 bits/min during slow walking (below 0.89 m/s).ConclusionsSSVEP-based BCI systems are deployable to users in treadmill walking that mimics natural walking rather than in highly-controlled laboratory settings. This study considerably promotes the use of a consumer-level EEG headset towards the real-life BCI applications
Translation of EEG spatial filters from resting to motor imagery using independent component analysis.
Electroencephalogram (EEG)-based brain-computer interfaces (BCIs) often use spatial filters to improve signal-to-noise ratio of task-related EEG activities. To obtain robust spatial filters, large amounts of labeled data, which are often expensive and labor-intensive to obtain, need to be collected in a training procedure before online BCI control. Several studies have recently developed zero-training methods using a session-to-session scenario in order to alleviate this problem. To our knowledge, a state-to-state translation, which applies spatial filters derived from one state to another, has never been reported. This study proposes a state-to-state, zero-training method to construct spatial filters for extracting EEG changes induced by motor imagery. Independent component analysis (ICA) was separately applied to the multi-channel EEG in the resting and the motor imagery states to obtain motor-related spatial filters. The resultant spatial filters were then applied to single-trial EEG to differentiate left- and right-hand imagery movements. On a motor imagery dataset collected from nine subjects, comparable classification accuracies were obtained by using ICA-based spatial filters derived from the two states (motor imagery: 87.0%, resting: 85.9%), which were both significantly higher than the accuracy achieved by using monopolar scalp EEG data (80.4%). The proposed method considerably increases the practicality of BCI systems in real-world environments because it is less sensitive to electrode misalignment across different sessions or days and does not require annotated pilot data to derive spatial filters
Multi-modal Approach for Affective Computing
Throughout the past decade, many studies have classified human emotions using
only a single sensing modality such as face video, electroencephalogram (EEG),
electrocardiogram (ECG), galvanic skin response (GSR), etc. The results of
these studies are constrained by the limitations of these modalities such as
the absence of physiological biomarkers in the face-video analysis, poor
spatial resolution in EEG, poor temporal resolution of the GSR etc. Scant
research has been conducted to compare the merits of these modalities and
understand how to best use them individually and jointly. Using multi-modal
AMIGOS dataset, this study compares the performance of human emotion
classification using multiple computational approaches applied to face videos
and various bio-sensing modalities. Using a novel method for compensating
physiological baseline we show an increase in the classification accuracy of
various approaches that we use. Finally, we present a multi-modal
emotion-classification approach in the domain of affective computing research.Comment: Published in IEEE 40th International Engineering in Medicine and
Biology Conference (EMBC) 201
Spatiotemporal Sparse Bayesian Learning with Applications to Compressed Sensing of Multichannel Physiological Signals
Energy consumption is an important issue in continuous wireless
telemonitoring of physiological signals. Compressed sensing (CS) is a promising
framework to address it, due to its energy-efficient data compression
procedure. However, most CS algorithms have difficulty in data recovery due to
non-sparsity characteristic of many physiological signals. Block sparse
Bayesian learning (BSBL) is an effective approach to recover such signals with
satisfactory recovery quality. However, it is time-consuming in recovering
multichannel signals, since its computational load almost linearly increases
with the number of channels.
This work proposes a spatiotemporal sparse Bayesian learning algorithm to
recover multichannel signals simultaneously. It not only exploits temporal
correlation within each channel signal, but also exploits inter-channel
correlation among different channel signals. Furthermore, its computational
load is not significantly affected by the number of channels. The proposed
algorithm was applied to brain computer interface (BCI) and EEG-based driver's
drowsiness estimation. Results showed that the algorithm had both better
recovery performance and much higher speed than BSBL. Particularly, the
proposed algorithm ensured that the BCI classification and the drowsiness
estimation had little degradation even when data were compressed by 80%, making
it very suitable for continuous wireless telemonitoring of multichannel
signals.Comment: Codes are available at:
https://sites.google.com/site/researchbyzhang/stsb
- …