52 research outputs found
3D correction of AIS in braces designed using CAD/CAM and FEM: a randomized controlled trial
Background
Recent studies showed that finite element model (FEM) combined to CAD/CAM improves the design of braces for the conservative treatment of adolescent idiopathic scoliosis (AIS), using 2D measurements from in-brace radiographs. We aim to assess the immediate effectiveness on curve correction in all three planes of braces designed using CAD/CAM and numerical simulation compared to braces designed with CAD/CAM only.
Methods
SRS standardized criteria for bracing were followed to recruit 48 AIS patients who were randomized into two groups. For both groups, 3D reconstructions of the spine and patient’s torso, respectively built from bi-planar radiographs and surface topography, were obtained and braces were designed using the CAD/CAM approach. For the test group, 3D reconstructions of the spine and patient’s torso were additionally used to generate a personalized FEM to simulate and iteratively improve the brace design with the objective of curve correction maximization in three planes and brace material minimization.
Results
For the control group (CtrlBraces), average Cobb angle prior to bracing was 29° (thoracic, T) and 25° (lumbar, L) with the planes of maximal curvature (PMC) respectively oriented at 63° and 57° on average with respect to the sagittal plane. Average apical axial rotation prior to bracing was 7° (T) and 9° (L). For the test group (FEMBraces), initial Cobb angles were 33° (T) and 28° (L) with the PMC at 68° (T) and 56° (L) and average apical axial rotation prior to bracing at 9° (T and L). On average, FEMBraces were 50% thinner and had 20% less covering surface than CtrlBraces while reducing T and L curves by 47 and 48%, respectively, compared to 25 and 26% for CtrlBraces. FEMBraces corrected apical axial rotation by 46% compared to 30% for CtrlBraces.
Conclusion
The combination of numerical simulation and CAD/CAM approach allowed designing more efficient braces in all three planes, with the advantages of being lighter than standard CAD/CAM braces. Bracing in AIS may be improved in 3D by the use of this simulation platform. This study is ongoing to recruit more cases and to analyze the long-term effect of bracing
Screening for adolescent idiopathic scoliosis: an information statement by the scoliosis research society international task force
Background: Routine screening of scoliosis is a controversial subject and screening efforts vary greatly around the world.
METHODS:
Consensus was sought among an international group of experts (seven spine surgeons and one clinical epidemiologist) using a modified Delphi approach. The consensus achieved was based on careful analysis of a recent critical review of the literature on scoliosis screening, performed using a conceptual framework of analysis focusing on five main dimensions: technical, clinical, program, cost and treatment effectiveness.
FINDINGS:
A consensus was obtained in all five dimensions of analysis, resulting in 10 statements and recommendations. In summary, there is scientific evidence to support the value of scoliosis screening with respect to technical efficacy, clinical, program and treatment effectiveness, but there insufficient evidence to make a statement with respect to cost effectiveness. Scoliosis screening should be aimed at identifying suspected cases of scoliosis that will be referred for diagnostic evaluation and confirmed, or ruled out, with a clinically significant scoliosis. The scoliometer is currently the best tool available for scoliosis screening and there is moderate evidence to recommend referral with values between 5 degrees and 7 degrees. There is moderate evidence that scoliosis screening allows for detection and referral of patients at an earlier stage of the clinical course, and there is low evidence suggesting that scoliosis patients detected by screening are less likely to need surgery than those who did not have screening. There is strong evidence to support treatment by bracing.
INTERPRETATION:
This information statement by an expert panel supports scoliosis screening in 4 of the 5 domains studied, using a framework of analysis which includes all of the World Health Organisation criteria for a valid screening procedure.IRSC (MOP864910
Effectiveness of braces designed using computer-aided design and manufacturing (CAD/CAM) and finite element simulation compared to CAD/CAM only for the conservative treatment of adolescent idiopathic scoliosis: a prospective randomized controlled trial
Purpose
Clinical assessment of immediate in-brace effect of braces designed using CAD/CAM and FEM vs. only CAD/CAM for conservative treatment of AIS, using a randomized blinded and controlled study design.
Methods
Forty AIS patients were prospectively recruited and randomized into two groups. For 19 patients (control group), the brace was designed using a scan of patient’s torso and a conventional CAD/CAM approach (CtrlBrace). For the 21 other patients (test group), the brace was additionally designed using finite element modeling (FEM) and 3D reconstructions of spine, rib cage and pelvis (NewBrace). The NewBrace design was simulated and iteratively optimized to maximize the correction and minimize the contact surface and material.
Results
Both groups had comparable age, sex, weight, height, curve type and severity. Scoliosis Research Society standardized criteria for bracing were followed. Average Cobb angle prior to bracing was 27° and 28° for main thoracic (MT) and lumbar (L) curves, respectively, for the control group, while it was 33° and 28° for the test group. CtrlBraces reduced MT and L curves by 8° (29 %) and 10° (40 %), respectively, compared to 14° (43 %) and 13° (46 %) for NewBraces, which were simulated with a difference inferior to 5°. NewBraces were 50 % thinner and had 20 % less covering surface than CtrlBraces.
Conclusion
Braces designed with CAD/CAM and 3D FEM simulation were more efficient and lighter than standard CAD/CAM TLSO’s at first immediate in-brace evaluation. These results suggest that long-term effect of bracing in AIS may be improved using this new platform for brace fabrication
The effectiveness of scoliosis screening programs: methods for systematic review and expert panel recommendations formulation
Background: Literature on scoliosis screening is vast, however because of the observational nature of available data and methodological flaws, data interpretation is often complex, leading to incomplete and sometimes, somewhat misleading conclusions. The need to propose a set of methods for critical appraisal of the literature about scoliosis screening, a comprehensive summary and rating of the available evidence appeared essential.
METHODS:
To address these gaps, the study aims were: i) To propose a framework for the assessment of published studies on scoliosis screening effectiveness; ii) To suggest specific questions to be answered on screening effectiveness instead of trying to reach a global position for or against the programs; iii) To contextualize the knowledge through expert panel consultation and meaningful recommendations. The general methodological approach proceeds through the following steps: Elaboration of the conceptual framework; Formulation of the review questions; Identification of the criteria for the review; Selection of the studies; Critical assessment of the studies; Results synthesis; Formulation and grading of recommendations in response to the questions. This plan follows at best GRADE Group (Grades of Recommendation, Assessment, Development and Evaluation) requirements for systematic reviews, assessing quality of evidence and grading the strength of recommendations.
CONCLUSIONS:
In this article, the methods developed in support of this work are presented since they may be of some interest for similar reviews in scoliosis and orthopaedic fields.Canadian Institutes of Health Research (CIHR) by three means: CIHR Research Operating Grants (2004–2007, 2008–2011); Canada Graduate Scholarships Doctoral Awards (MB) and CIHR MENTOR and AnEIS Strategic training programs doctoral awards (MB)
Has Simeon's vision prevailed among Canadian policy scholars?
Concerned by the proliferation of idiosyncratic prescriptive case studies in the nascent subfield of policy studies, Richard Simeon, in his seminal 1976 article, asked scholars to produce more comparative policy research that aimed at explaining general events and contributing to theory building. The extent to which Simeon's vision materialized remains debated. With a view to informing this debate, we conducted a systematic content analysis of the articles published in five major generalist public policy journals from 1980 to 2015. The analysis reveals that Canadian policy scholars took a comparative turn, publishing more territorial, sector and time comparisons than in the past. We also found evidence that theoretical knowledge accumulation is more important today for Canadian authors than it was when Simeon wrote his article.</p
- …