818 research outputs found
An Assessment of the Net Value of CSP Systems Integrated with Thermal Energy Storage
AbstractWithin this study, we evaluate the operational and capacity value—or total system value—for multiple concentrating solar power (CSP)plant configurations under an assumed 33% renewable penetration scenario in California. We calculate the first-year bid price for two CSP plants, including a 2013 molten-salt tower integrated with a conventional Rankine cycle and a hypothetical 2020 molten-salt tower system integrated with an advanced supercritical carbon-dioxide power block. The overall benefit to the regional grid, defined in this study as the net value, is calculated by subtracting the first-year bid price from the total system value.Re--sults of this study indicate a positive net value for a variety of scenarios, depending on technology assumptions and assumed values for natural gas price and tax incentives. We provide results for the 2013 and 2020 CSP configurations as a function of thermal energy storage capacity and solar field size. We provide a sensitivity of these results to natural gas price, which influence the operation value and thus the total system value. We also investigate the sensitivity of the net value to current and anticipated tax incentives
Recommended from our members
Solving widespread low-concentration VOC air pollution problems: Gas-phase photocatalytic oxidation answers the needs of many small businesses
Many small businesses are facing new regulations under the 1990 Amendments to the Clean Air Act. Regulators, as well as the businesses themselves, face new challenges to control small point-source air pollution emissions. An individual business-such as a dry cleaner, auto repair shop, bakery, coffee roaster, photo print shop, or chemical company-may be an insignificant source of air pollution, but collectively, the industry becomes a noticeable source. Often the businesses are not equipped to respond to new regulatory requirements because of limited resources, experience, and expertise. Also, existing control strategies may be inappropriate for these businesses, having been developed for major industries with high volumes, high pollutant concentrations, and substantial corporate resources. Gas-phase photocatalytic oxidation (PCO) is an option for eliminating low-concentration, low-flow-rate emissions of volatile organic compounds (VOCs) from small business point sources. The advantages PCO has over other treatment techniques are presented in this paper. This paper also describes how PCO can be applied to specific air pollution problems. We present our methodology for identifying pollution problems for which PCO is applicable and for reaching the technology`s potential end users. PCO is compared to other gas-phase VOC control technologies
Solar-Augment Potential of U.S. Fossil-Fired Power Plants
Concentrating Solar Power (CSP) systems utilize solar thermal energy for the generation of electric power. This attribute makes it relatively easy to integrate CSP systems with fossil-fired power plants. The 'solar-augment' of fossil power plants offers a lower cost and lower risk alternative to stand-alone solar plant construction. This study ranked the potential to add solar thermal energy to coal-fired and natural gas combined cycle (NGCC) plants found throughout 16 states in the southeast and southwest United States. Each generating unit was ranked in six categories to create an overall score ranging from Excellent to Not Considered. Separate analysis was performed for parabolic trough and power tower technologies due to the difference in the steam temperatures that each can generate. The study found a potential for over 11 GWe of parabolic trough and over 21 GWe of power tower capacity. Power towers offer more capacity and higher quality integration due to the greater steam temperatures that can be achieved. The best sites were in the sunny southwest, but all states had at least one site that ranked Good for augmentation
Molten Salt Power Tower Cost Model for the System Advisor Model (SAM)
This report describes a component-based cost model developed for molten-salt power tower solar power plants. The cost model was developed by the National Renewable Energy Laboratory (NREL), using data from several prior studies, including a contracted analysis from WorleyParsons Group, which is included herein as an Appendix. The WorleyParsons' analysis also estimated material composition and mass for the plant to facilitate a life cycle analysis of the molten salt power tower technology. Details of the life cycle assessment have been published elsewhere. The cost model provides a reference plant that interfaces with NREL's System Advisor Model or SAM. The reference plant assumes a nominal 100-MWe (net) power tower running with a nitrate salt heat transfer fluid (HTF). Thermal energy storage is provided by direct storage of the HTF in a two-tank system. The design assumes dry-cooling. The model includes a spreadsheet that interfaces with SAM via the Excel Exchange option in SAM. The spreadsheet allows users to estimate the costs of different-size plants and to take into account changes in commodity prices. This report and the accompanying Excel spreadsheet can be downloaded at https://sam.nrel.gov/cost
Experimental infection with Yersinia pseudotuberculosis in European brown hare (Lepus europaeus, Pallas)
Objective To investigate clinicopathological, bacteriological and pathological aspects of an experimental infection with Yersinia pseudotuberculosis (Y. pseudotuberculosis) in hares to verify the efficacy of serology for the in vivo diagnosis. Moreover, the pathogenicity of two Y. pseudotuberculosis strains was investigated in order to detect potential differences. Methods Twelve European brown hares (Lepus europaeus, Pallas) were experimentally infected per os and via conjunctival mucosae with Y. pseudotuberculosis: six subjects were infected with a strain isolated from a naturally infected hare (YpH) and six subjects with a strain isolated from a naturally infected rabbit (YpR). Two hares were used as negative controls. All animals were subjected to clinical, bacteriological and serological examinations during 9 weeks following the infection and, at the end of the control period, subjects still alive were euthanized and submitted to a complete post mortem examination. Results All faecal samples collected during the control period were positive for bacteriological examinations and to a PCR for the inv gene of Y. pseudotuberculosis, while only one YpH-infected hare showed a positive haemocultures. From the 2nd to the 9th week post infection (pi), serological analysis revealed specific antibodies with titers ranging from 1:10 to 1:160 in all YpH-infected and two YpR-infected subjects. All the YpH-infected and two YpR-infected hares scored positive for Y. pseudotuberculosis by means of bacteriological investigations. Grossly, suppurative multifocal lesions were detected in liver, spleen, kidney and sub-mandibular lymph nodes in both YpH- and YpR-infected hares and confirmed with histopathology. Pulmonary lesions were observed only in YpH-infected subjects. Immunohistochemistry confirmed the presence of bacterial antigen in all infected animals. Conclusion Results of this study revealed that YpH strain is more pathogenic for hares than the YpR strain; moreover the serological test performed in this study could be used for the diagnosis of pseudotuberculosis in hares, whereas post mortem diagnosis should be confirmed by means of bacteriological examination, PCR, histopathology and immunohistochemistry
Modeling multi effect distillation powered by CSP in TRNSYS
This work presents the results of using a new tool to simulate the cogeneration of water and electricity with Concentrating Solar Power (CSP) and Forward Feed Multi-Effect-Desalination (FF-MED) plants, by adding a new functionality to the System Advisor Model (SAM) developed by the US National Renewable Energy Laboratory (NREL). The controlling strategy of the MED model is presented in detail, and a case study application is shown. This study compares the results obtained with a CSP plant operating in San Diego, CA, with four different cooling systems: an MED/Seawater Cooling Circuit (SWCC), dry cooling, wet cooling, and a SWCC standalone. The results show that the usage of an MED/SWCC system in cogeneration with a CSP plant can be feasible and has the potential to be economically interesting
Effects of magnetic field and disorder on electronic properties of Carbon Nanotubes
Electronic properties of metallic and semiconducting carbon nanotubes are
investigated in presence of magnetic field perpendicular to the CN-axis, and
disorder introduced through energy site randomness. The magnetic field field is
shown to induce a metal-insulator transition (MIT) in absence of disorder, and
surprisingly disorder does not affect significantly the MIT. These results may
find confirmation through tunneling experimentsComment: 4 pages, 6 figures. Phys. Rev. B (in press
Recommended from our members
Water Use in Parabolic Trough Power Plants: Summary Results from WorleyParsons' Analyses
The National Renewable Energy Laboratory (NREL) contracted with WorleyParsons Group, Inc. to examine the effect of switching from evaporative cooling to alternative cooling systems on a nominal 100-MW parabolic trough concentrating solar power (CSP) plant. WorleyParsons analyzed 13 different cases spanning three different geographic locations (Daggett, California; Las Vegas, Nevada; and Alamosa, Colorado) to assess the performance, cost, and water use impacts of switching from wet to dry or hybrid cooling systems. NREL developed matching cases in its Solar Advisor Model (SAM) for each scenario to allow for hourly modeling and provide a comparison to the WorleyParsons results.Our findings indicate that switching from 100% wet to 100% dry cooling will result in levelized cost of electricity (LCOE) increases of approximately 3% to 8% for parabolic trough plants throughout most of the southwestern United States. In cooler, high-altitude areas like Colorado's San Luis Valley, WorleyParsons estimated the increase at only 2.5%, while SAM predicted a 4.4% difference. In all cases, the transition to dry cooling will reduce water consumption by over 90%. Utility time-of-delivery (TOD) schedules had similar impacts for wet- and dry-cooled plants, suggesting that TOD schedules have a relatively minor effect on the dry-cooling penalty
Electrographic seizure duration and inter-seizure intervals in focal status epilepticus
Objective: To characterize the duration of seizures and inter-seizure intervals in focal status epilepticus (SE). Methods: We reviewed consecutive scalp EEG recordings from adult patients who were admitted for a first episode of focal status epilepticus. We identified electrographic seizure duration and inter-seizure intervals in the first diagnostic pretreatment EEG. We also reviewed isolated focal self-limiting seizures in epilepsy patients, as a comparison group for seizure duration. Results: We recorded 307 focal seizures in 100 consecutive focal SE episodes, with a median seizure duration of 107 s (IQR: 54–186), and 134 isolated focal self-limiting seizures in 42 epilepsy patients, with a median duration of 59 s (IQR: 30–90; p <.001). The only clinical feature of SE that significantly increased seizure duration was acute symptomatic etiology. In SE, 15% and 7% of seizures lasted longer than 300 and 600 s, respectively (t1 of the actual definition for tonic–clonic and focal SE), while only 1% of self-limiting seizures lasted longer than 300 s, and none lasted longer than 600 s. The analysis of inter-seizure intervals in SE with multiple seizures showed that 50% of the inter-seizure periods were shorter than 60 s, and 95% were shorter than 540 s (9 min). Patients who had an increase in seizure duration (last versus first) of at least 1.4 times showed an increased 30-day mortality. Significance: Focal seizures within a SE episode showed a wide range of duration, partly overlapping with the duration of focal self-limiting seizures but with a longer median duration. Inter-seizure intervals within an episode of SE were shorter than 1 min in 50% of the seizures and never lasted more than 10 min. Finally, an increase in seizure duration could represent an “electrophysiological biomarker” of a more severe SE episode, which may require more aggressive and rapid treatment
- …