16 research outputs found

    Integrated optical immunofluorescence multisensor for river pollution

    No full text
    A 32-analyte integrated optical immunofluorescence multisensor system has been realised and tested for the first time. The sensor system is based upon bio/immuno-chemistry at the waveguide surface and fluoroimmunoassay in the evanescent fields of the optical waveguides, to enable rapid, simultaneous and high-sensitivity fluorescence detection of up to 32 pollutants in water, and automatic regeneration for immediate reuse. The system has been demonstrated for estrone and a detection limit of 13 ng/L has been achieved

    Automated water analyser computer supported system (AWACSS): Part II: Intelligent remote-controlled cost-effective on-line water-monitoring measurement system

    No full text
    A novel analytical system AWACSS (Automated Water Analyser Computer Supported System) based on immunochemical technology has been evaluated that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration or pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) [98/83/EC, 1998. Council Directive (98/83/EC) of 3 November 1998 relating to the quality of water intended for human consumption. Off. J. Eur. Commun. L330, 32-54] and Water Framework Directive (WFD) [2000/60/EC, 2000. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy. Off. J. Eur. Commun. L327, 1-72], drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The first part article gave the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional analytical methods. The system's capability for analysing a wide range of environmental organic micro-pollutants, such as modern pesticides, endocrine disrupting compounds and pharmaceuticals in surface, ground, drinking and waste water is shown. In addition, a protocol using reconstitution of extracts of solid samples, developed and applied for analysis of river sediments and food samples, is presented. Finally, the overall performance of the AWACSS system in comparison to the conventional analytical techniques, which included liquid and gas chromatographic systems with diode-array UV and mass spectrometric detectors, was successfully tested in an inter-laboratory collaborative trial among six project partners

    Automated water analyser computer supported system (AWACSS): Part I: project objectives basic technology immunoassay development software design and networking

    No full text
    A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps.Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe.This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional analytical methods

    Biosensors for unattended cost-effective and continuous monitoring of environmental pollution: Automated water analyser computer supported system (AWACSS) and river analyser (RIANA)

    No full text
    This work describes our recent progress and achievements in the field of fully automated biosensors (Automated Water Analyser Computer Supported System (AWACSS) and River Analyser (RIANA)) for unattended, cost-effective and continuous monitoring of environmental pollution. We report on ultra-sensitive immunoassays for the hormones progesterone, testosterone and estrone and the pesticides propanil and isoproturon as examples of the outstanding progress made on biosensors in the field of environmental monitoring and water analysis. Most of the bio-active organic pollutants (estrone, progesterone, propanil and isoproturon) were detected at levels as low as 1.0pgm/L or even below. In fact, the reported limits of detection (LOD) were between 0.2 and 6.0pgm/L. For the first time, commercially available derivatives and antibodies were incorporated into immunoassays (progesterone and testosterone) for fully automated biosensors. To verify the assay performance for quantifying testosterone, progesterone, and isoproturon in real-world samples using our immunosensors, we spiked river and drinking water at six different levels from 0.9pgm/L to 90ngm/L. Nearly all recovery rates could be obtained between 70 and 120% as the AOAC International recommends it chiefly for water analysis
    corecore