31 research outputs found

    Automatic Detection and Classification of Breast Tumors in Ultrasonic Images Using Texture and Morphological Features

    Get PDF
    Due to severe presence of speckle noise, poor image contrast and irregular lesion shape, it is challenging to build a fully automatic detection and classification system for breast ultrasonic images. In this paper, a novel and effective computer-aided method including generation of a region of interest (ROI), segmentation and classification of breast tumor is proposed without any manual intervention. By incorporating local features of texture and position, a ROI is firstly detected using a self-organizing map neural network. Then a modified Normalized Cut approach considering the weighted neighborhood gray values is proposed to partition the ROI into clusters and get the initial boundary. In addition, a regional-fitting active contour model is used to adjust the few inaccurate initial boundaries for the final segmentation. Finally, three textures and five morphologic features are extracted from each breast tumor; whereby a highly efficient Affinity Propagation clustering is used to fulfill the malignancy and benign classification for an existing database without any training process. The proposed system is validated by 132 cases (67 benignancies and 65 malignancies) with its performance compared to traditional methods such as level set segmentation, artificial neural network classifiers, and so forth. Experiment results show that the proposed system, which needs no training procedure or manual interference, performs best in detection and classification of ultrasonic breast tumors, while having the lowest computation complexity

    2D perfusion DSA with an open-source, semi-automated, color-coded software for the quantification of foot perfusion following infrapopliteal angioplasty: a feasibility study

    No full text
    Background: Foot perfusion has been recently implemented as a new tool for optimizing outcomes of peripheral endovascular procedures. A custom-made, two-dimensional perfusion digital subtraction angiography (PDSA) algorithm has been implemented to quantify outcomes of endovascular treatment of critical limb ischemia (CLI), assist intra-procedural decision-making, and enhance clinical outcomes. Methods: The study was approved by the Hospital’s Ethics Committee. This prospective, single-center study included seven consecutive patients scheduled to undergo infrapopliteal endovascular treatment of CLI. Perfusion blood volume (PBV), mean transit time (MTT), and perfusion blood flow (PBF) maps were extracted by analyzing time-intensity curves and signal intensity on the perfused vessel mask. Mean values calculated from user-specified regions of interest (ROIs) on perfusion maps were employed to evaluate pre- and post-endovascular treatment condition. Measurements were performed immediately after final PDSA. Results: In total, five patients (aged 54 ± 16 years, mean ± standard deviation) were analyzed, as two patients were excluded due to significant motion artifacts. Post-procedural MTT presented a mean decrease of 19.1% for all patients and increased only in 1 of 5 patients, demonstrating in 4/5 patients an increase in tissue perfusion after revascularization. Overall mean PBF and PBV values were also analogously increased following revascularization (446% and 69.5% mean, respectively) and in the majority of selected ROIs (13/15 and 12/15 ROIs, respectively). Conclusions: Quantification of infrapopliteal angioplasty outcomes using this newly proposed, custom-made, intra-procedural PDSA algorithm was performed using PBV, MTT, and PBF maps. Further studies are required to determine its role in peripheral endovascular procedures (ClinicalTrials.gov Identifier: NCT04356092). © 2020, The Author(s)

    Focal liver lesions segmentation and classification in nonenhanced T2-weighted MRI:

    No full text
    Purpose: To automatically segment and classify focal liver lesions (FLLs) on nonenhanced T2-weighted magnetic resonance imaging (MRI) scans using a computer-aided diagnosis (CAD) algorithm. Methods: 71 FLLs (30 benign lesions, 19 hepatocellular carcinomas, and 22 metastases) on T2-weighted MRI scans were delineated by the proposed CAD scheme. The FLL segmentation procedure involved wavelet multiscale analysis to extract accurate edge information and mean intensity values for consecutive edges computed using horizontal and vertical analysis that were fed into the subsequent fuzzy C-means algorithm for final FLL border extraction. Texture information for each extracted lesion was derived using 42 first- and second-order textural features from grayscale value histogram, co-occurrence, and run-length matrices. Twelve morphological features were also extracted to capture any shape differentiation between classes. Feature selection was performed with stepwise multilinear regression analysis that led to a reduced feature subset. A multiclass Probabilistic Neural Network (PNN) classifier was then designed and used for lesion classification. PNN model evaluation was performed using the leave-one-out (LOO) method and receiver operating characteristic (ROC) curve analysis. Results: The mean overlap between the automatically segmented FLLs and the manual segmentations performed by radiologists was 0.91 ± 0.12. The highest classification accuracies in the PNN model for the benign, hepatocellular carcinoma, and metastatic FLLs were 94.1%, 91.4%, and 94.1%, respectively, with sensitivity/specificity values of 90%/97.3%, 89.5%/92.2%, and 90.9%/95.6% respectively. The overall classification accuracy for the proposed system was 90.1%. Conclusions: Our diagnostic system using sophisticated FLL segmentation and classification algorithms is a powerful tool for routine clinical MRI-based liver evaluation and can be a supplement to contrast-enhanced MRI to prevent unnecessary invasive procedures. © 2017 American Association of Physicists in Medicine

    A Machine-Learning Algorithm Toward Color Analysis for Chronic Liver Disease Classification, Employing Ultrasound Shear Wave Elastography

    No full text
    The purpose of the present study was to employ a computer-aided diagnosis system that classifies chronic liver disease (CLD) using ultrasound shear wave elastography (SWE) imaging, with a stiffness value-clustering and machine-learning algorithm. A clinical data set of 126 patients (56 healthy controls, 70 with CLD) was analyzed. First, an RGB-to-stiffness inverse mapping technique was employed. A five-cluster segmentation was then performed associating corresponding different-color regions with certain stiffness value ranges acquired from the SWE manufacturer-provided color bar. Subsequently, 35 features (7 for each cluster), indicative of physical characteristics existing within the SWE image, were extracted. A stepwise regression analysis toward feature reduction was used to derive a reduced feature subset that was fed into the support vector machine classification algorithm to classify CLD from healthy cases. The highest accuracy in classification of healthy to CLD subject discrimination from the support vector machine model was 87.3% with sensitivity and specificity values of 93.5% and 81.2%, respectively. Receiver operating characteristic curve analysis gave an area under the curve value of 0.87 (confidence interval: 0.77–0.92). A machine-learning algorithm that quantifies color information in terms of stiffness values from SWE images and discriminates CLD from healthy cases is introduced. New objective parameters and criteria for CLD diagnosis employing SWE images provided by the present study can be considered an important step toward color-based interpretation, and could assist radiologists’ diagnostic performance on a daily basis after being installed in a PC and employed retrospectively, immediately after the examination. © 2017 World Federation for Ultrasound in Medicine & Biolog

    Temporal stability assessment in shear wave elasticity images validated by deep learning neural network for chronic liver disease fibrosis stage assessment

    No full text
    Purpose: To automatically detect and isolate areas of low and high stiffness temporal stability in shear wave elastography (SWE) image sequences and define their impact in chronic liver disease (CLD) diagnosis improvement by means of clinical examination study and deep learning algorithm employing convolutional neural networks (CNNs). Materials and Methods: Two hundred SWE image sequences from 88 healthy individuals (F0 fibrosis stage) and 112 CLD patients (46 with mild fibrosis (F1), 16 with significant fibrosis (F2), 22 with severe fibrosis (F3), and 28 with cirrhosis (F4)) were analyzed to detect temporal stiffness stability between frames. An inverse Red, Green, Blue (RGB) colormap-to-stiffness process was performed for each image sequence, followed by a wavelet transform and fuzzy c-means clustering algorithm. This resulted in a binary mask depicting areas of high and low stiffness temporal stability. The mask was then applied to the first image of the SWE sequence, and the derived, masked SWE image was used to estimate its impact in standard clinical examination and CNN classification. Regarding the impact of the masked SWE image in clinical examination, one measurement by two radiologists was performed in each SWE image and two in the corresponding masked image measuring areas with high and low stiffness temporal stability. Then, stiffness stability parameters, interobserver variability evaluation and diagnostic performance by means of ROC analysis were assessed. The masked and unmasked sets of SWE images were fed into a CNN scheme for comparison. Results: The clinical impact evaluation study showed that the masked SWE images decreased the interobserver variability of the radiologists’ measurements in the high stiffness temporal stability areas (interclass correlation coefficient (ICC) = 0.92) compared to the corresponding unmasked ones (ICC = 0.76). In terms of diagnostic accuracy, measurements in the high-stability areas of the masked SWE images (area-under-the-curve (AUC) ranging from 0.800 to 0.851) performed similarly to those in the unmasked SWE images (AUC ranging from 0.805 to 0.893). Regarding the measurements in the low stiffness temporal stability areas of the masked SWE images, results for interobserver variability (ICC = 0.63) and diagnostic accuracy (AUC ranging from 0.622 to 0.791) were poor. Regarding the CNN classification, the masked SWE images showed improved accuracy (ranging from 82.5% to 95.5%) compared to the unmasked ones (ranging from 79.5% to 93.2%) for various CLD stage combinations. Conclusion: Our detection algorithm excludes unreliable areas in SWE images, reduces interobserver variability, and augments CNN's accuracy scores for many combinations of fibrosis stages. © 2019 American Association of Physicists in Medicin

    A new computer aided diagnosis system for evaluation of chronic liver disease with ultrasound shear wave elastography imaging

    No full text
    Purpose: Classify chronic liver disease (CLD) from ultrasound shear-wave elastography (SWE) imaging by means of a computer aided diagnosis (CAD) system. Methods: The proposed algorithm employs an inverse mapping technique (red-green-blue to stiffness) to quantify 85 SWE images (54 healthy and 31 with CLD). Texture analysis is then applied involving the automatic calculation of 330 first and second order textural features from every transformed stiffness value map to determine functional features that characterize liver elasticity and describe liver condition for all available stages. Consequently, a stepwise regression analysis feature selection procedure is utilized toward a reduced feature subset that is fed into the support vector machines (SVMs) classification algorithm in the design of the CAD system. Results: With regard to the mapping procedure accuracy, the stiffness map values had an average difference of 0.01?0.001 kPa compared to the quantification results derived from the color-box provided by the built-in software of the ultrasound system. Highest classification accuracy from the SVM model was 87.0% with sensitivity and specificity values of 83.3% and 89.1%, respectively. Receiver operating characteristic curves analysis gave an area under the curve value of 0.85 with [0.770.89] confidence interval. Conclusions: The proposed CAD system employing color to stiffness mapping and classification algorithms offered superior results, comparing the already published clinical studies. It could prove to be of value to physicians improving the diagnostic accuracy of CLD and can be employed as a second opinion tool for avoiding unnecessary invasive procedures. © 2016 Am. Assoc. Phys. Med

    Deep learning networks on chronic liver disease assessment with fine-tuning of shear wave elastography image sequences

    No full text
    Chronic liver disease (CLD) is currently one of the major causes of death worldwide. If not treated, it may lead to cirrhosis, hepatic carcinoma and death. Ultrasound (US) shear wave elastography (SWE) is a relatively new, popular, non-invasive technique among radiologists. Although many studies have been published validating the SWE technique either in a clinical setting, or by applying machine learning on SWE elastograms, minimal work has been done on comparing the performance of popular pre-trained deep learning networks on CLD assessment. Currently available literature reports suggest technical advancements on specific deep learning structures, with specific inputs and usually on a limited CLD fibrosis stage class group, with limited comparison on competitive deep learning schemes fed with different input types. The aim of the present study is to compare some popular deep learning pre-trained networks using temporally stable and full elastograms, with or without augmentation as well as propose suitable deep learning schemes for CLD diagnosis and progress assessment. 200 liver biopsy validated patients with CLD, underwent US SWE examination. Four images from the same liver area were saved to extract elastograms and processed to exclude areas that were temporally unstable. Then, full and temporally stable masked elastograms for each patient were separately fed into GoogLeNet, AlexNet, VGG16, ResNet50 and DenseNet201 with and without augmentation. The networks were tested for differentiation of CLD stages in seven classification schemes over 30 repetitions using liver biopsy as the reference. All networks achieved maximum mean accuracies ranging from 87.2%-97.4% and area under the receiver operating characteristic curves (AUCs) ranging from 0.979-0.990 while the radiologists had AUCs ranging from 0.800-0.870. ResNet50 and DenseNet201 had better average performance than the other networks. The use of the temporal stability mask led to improved performance on about 50% of inputs and network combinations while augmentation led to lower performance for all networks. These findings can provide potential networks with higher accuracy and better setting in the CLD diagnosis and progress assessment. A larger data set would help identify the best network and settings for CLD assessment in clinical practice. © 2020 Institute of Physics and Engineering in Medicine
    corecore