27,683 research outputs found
Constraints on the long-period moment-dip tradeoff for the Tohoku earthquake
Since the work of Kanamori and Given (1981), it has been recognized that shallow, pure dip-slip earthquakes excite long-period surface waves such that it is difficult to independently constrain the moment (M_0) and the dip (δ) of the source mechanism, with only the product M_0 sin(2δ) being well constrained. Because of this, it is often assumed that the primary discrepancies between the moments of shallow, thrust earthquakes are due to this moment-dip tradeoff. In this work, we quantify how severe this moment-dip tradeoff is depending on the depth of the earthquake, the station distribution, the closeness of the mechanism to pure dip-slip, and the quality of the data. We find that both long-period Rayleigh and Love wave modes have moment-dip resolving power even for shallow events, especially when stations are close to certain azimuths with respect to mechanism strike and when source depth is well determined. We apply these results to USGS W phase inversions of the recent M9.0 Tohoku, Japan earthquake and estimate the likely uncertainties in dip and moment associated with the moment- dip tradeoff. After discussing some of the important sources of moment and dip error, we suggest two methods for potentially improving this uncertainty
Clinical Response and Autonomic Modulation as Seen in Heart Rate Variability in Mechanical Intermittent Cervical Traction: A Pilot Study
[[abstract]]OBJECTIVE: To determine the influence of mechanical intermittent cervical traction on the autonomic system.
DESIGN: Prospective, cases series study.
SUBJECTS: Sixteen healthy volunteers without contraindications for cervical traction.
METHODS: Subjects received mechanical intermittent cervical traction in a sitting position under two traction forces (10% and 20% of total body weight). Electrocardiographic and neck surface electromyographic signals were recorded and analysed from 3 5-min periods (before, during and after traction). Subjective symptoms, heart rate and heart rate variability parameters, including standard deviation of all normal-to-normal beat intervals, very low-frequency power, low-frequency power, high-frequency power, multiscale entropy, slope of multiscale entropy, and root mean square value of electromyography amplitude were statistically compared.
RESULTS: This pilot study showed that using 10% body weight traction force was more comfortable than using 20% body weight. Only subtle perturbation was noted in the autonomic system when using 20% body weight traction force.
CONCLUSION: The response pattern of heart rate variability analysis in this pilot study provides some early information about individual discomfort in cervical traction. The autonomic modulation and the safety of cervical traction with other modality settings or in patients with neck pain require further study.[[notice]]補正完畢[[incitationindex]]SCI[[booktype]]紙
A physical model for seismic noise generation from sediment transport in rivers
Measuring sediment flux in rivers remains a significant problem in studies of landscape evolution. Recent studies suggest that observations of seismic noise near rivers can help provide such measurements, but the lack of models linking observed seismic quantities to sediment flux has prevented the method from being used. Here, we develop a forward model to describe the seismic noise induced by the transport of sediment in rivers. The model provides an expression for the power spectral density (PSD) of the Rayleigh waves generated by impulsive impacts from saltating particles which scales linearly with the number of particles of a given size and the square of the linear momentum. After incorporating expressions for the impact velocity and rate of impacts for fluvially transported sediment, we observe that the seismic noise PSD is strongly dependent on the sediment size, such that good constraints on grain size distribution are needed for reliable estimates of sediment flux based on seismic noise observations. The model predictions for the PSD are consistent with recent measurements and, based on these data, a first attempt at inverting seismic noise for the sediment flux is provided
Dynamical Properties of a Growing Surface on a Random Substrate
The dynamics of the discrete Gaussian model for the surface of a crystal
deposited on a disordered substrate is investigated by Monte Carlo simulations.
The mobility of the growing surface was studied as a function of a small
driving force and temperature . A continuous transition is found from
high-temperature phase characterized by linear response to a low-temperature
phase with nonlinear, temperature dependent response. In the simulated regime
of driving force the numerical results are in general agreement with recent
dynamic renormalization group predictions.Comment: 10 pages, latex, 3 figures, to appear in Phys. Rev. E (RC
An explicit relationship between time-domain noise correlation and spatial autocorrelation (SPAC) results
The success of recent ambient noise tomographic studies is now understood to arise due to cross-correlation properties documented in the acoustics community since the 1950s. However, despite the fact that Aki's 1957 spatial autocorrelation (SPAC) work yields identical analytical results to certain noise correlation results, the precise relationship between SPAC and time-domain cross-correlation remains not entirely transparent. Here, we present an explicit comparison of the two approaches and clarify that SPAC theory is indeed equivalent to the cross-correlation theory used for recent noise tomography studies. This equivalence allows theoretical work from each field to be applied to the other, and we illustrate a few examples of this
Metal Transfer in Arc Welding
A double pulse welding current method is disclosed for the generation and transfer of droplets of welding metal from an electrode wire to a workpiece in an arc welding process. A suitable background direct current level is specified to deliver a desired number of droplets to the weld site. During each cycle of droplet formation and transfer, a first increased current pulse is applied to the electrode and arc to generate a droplet on the tip of and electrode and then a second further increased current pulse is applied to timely separate the droplet from the electrode for transport in the arc to the workpiece. This double-pulse current application reliably produces one droplet per cycle of pulses to deliver a specified number of droplets to the weld site for improved weld quality and reduced spatter or waste of weld metal
Method of Metallurgically Bonding Articles and Article Therefor
An article suitable for metallurgical bonding having a first part having a lower surface, and a second part having an upper surface is disclosed. The lower surface of the first part is disposed at the upper surface of the second part to provide for a faying surface thereat. The faying surface has a plurality of channels having a depth equal to or greater than about 1 micron and equal to or less than about 1000 microns. The article is suitable for metallurgical bonding at the faying surface
- …