49 research outputs found

    Diagnostic and Prognostic Utility of Procalcitonin in Patients Presenting to the Emergency Department with Dyspnea

    Get PDF
    Background Among patients in the emergency department, dyspnea is a common complaint and can pose a diagnostic challenge. Biomarkers are used increasingly to improve diagnostic accuracy and aid with prognostication in dyspneic patients. The purpose of this study was to examine the clinical utility of serum procalcitonin (PCT) for the diagnosis of pneumonia in patients presenting to the emergency department with dyspnea. A secondary objective was to evaluate the prognostic value of PCT for death to 1 year. Methods This study pooled the patient populations of 2 prospective cohorts that previously enrolled patients presenting to 2 urban emergency departments with dyspnea. A total of 453 patients had serum samples available for biomarker analysis. Clinician certainty for the diagnosis of acutely decompensated heart failure was reviewed. Discrimination, calibration, and net reclassification improvement for the diagnosis of pneumonia as well as fatal outcomes were considered. The main outcome was accuracy of PCT for diagnostic categorization of pneumonia. The prognostic value of PCT for survival to 1 year was a secondary outcome. Results Pneumonia alone was diagnosed in 30 patients (6.6%), heart failure without pneumonia in 212 patients (47%), and both diagnoses in 30 patients (6.6%). Procalcitonin concentrations were higher in subjects with pneumonia (0.38 vs 0.06 ng/mL; P < .001). Area under the receiver operating characteristic curve for the diagnosis of pneumonia based on PCT was 0.84 (95% confidence interval [CI], 0.77-0.91; P < .001). Across all levels of clinician-based estimates of heart failure, PCT was sensitive and specific; notably, in patients judged with diagnostic uncertainty (n = 70), a PCT value of 0.10 ng/mL had the optimal balance of sensitivity and specificity (80% and 77%, respectively) for pneumonia. Adding PCT results to variables predictive of pneumonia resulted in a net reclassification improvement of 0.54 (95% CI, 0.24-0.83; P < .001) for both up- and down-reclassifying events. In adjusted analyses, elevated PCT was a predictor of 1-year mortality (hazard ratio 1.8; 95% CI, 1.4-2.3; P < .001) and was additive when elevated in conjunction with natriuretic peptides for this application. Conclusion In emergency department patients with acute dyspnea, PCT is an accurate diagnostic marker for pneumonia and adds independent prognostic information for 1-year mortality

    Electrocardiographic Left Ventricular Hypertrophy and Outcome in Hemodialysis Patients

    Get PDF
    BACKGROUND AND AIMS: Electrocardiography (ECG) is the most widely used initial screening test for the assessment of left ventricular hypertrophy (LVH), an independent predictor of cardiovascular mortality in patients with end-stage renal disease (ESRD). However, traditional ECG criteria based only on voltage to detect LVH have limited clinical utility for the detection of LVH because of their poor sensitivity. METHODS: This prospective observational study was undertaken to compare the prognostic significance of commonly used ECG criteria for LVH, namely Sokolow-Lyon voltage (SV) or voltage-duration product (SP) and Cornell voltage (CV) or voltage-duration product (CP) criteria, and to investigate the association between echocardiographic LV mass index (LVMI) and ECG-LVH criteria in ESRD patients, who consecutively started maintenance hemodialysis (HD) between January 2006 and December 2008. RESULTS: A total of 317 patients, who underwent both ECG and echocardiography, were included. Compared to SV and CV criteria, SP and CP criteria, respectively, correlated more closely with LVMI. In addition, CP criteria provided the highest positive predictive value for echocardiographic LVH. The 5-year cardiovascular survival rates were significantly lower in patients with ECG-LVH by each criterion. In multivariate analyses, echocardiographic LVH [adjusted hazard ratio (HR): 11.71; 95% confidence interval (CI): 1.57-87.18; P = 0.016] and ECG-LVH by SP (HR: 3.43; 95% CI: 1.32-8.92; P = 0.011) and CP (HR: 3.07; 95% CI: 1.16-8.11; P = 0.024) criteria, but not SV and CV criteria, were significantly associated with cardiovascular mortality. CONCLUSIONS: The product of QRS voltage and duration is helpful in identifying the presence of LVH and predicting cardiovascular mortality in incident HD patients

    Bilateral Coronary Artery Fistula Draining into the Coronary Sinus

    No full text

    A novel electrocardiographic index for the diagnosis of diastolic dysfunction

    Get PDF
    Contains fulltext : 128595.pdf (publisher's version ) (Open Access)BACKGROUND: Although the assessment of diastolic dysfunction (DD) is an integral part of routine cardiologic examinations, little is known about associated electrocardiographic (ECG) changes. Our aim was to investigate a potential role of ECG indices for the recognition of patients with DD. METHODS AND RESULTS: ECG parameters correlating with echocardiographic findings of DD were retrospectively assessed in a derivation group of 172 individuals (83 controls with normal diastolic function, 89 patients with DD) and their diagnostic performance was tested in a validation group of 50 controls and 50 patients. The patient group with a DD Grade 1 and 2 showed longer QTc (422+/-24ms and 434+/-32ms vs. 409+/-25ms, p<0.0005) and shorter Tend-P and Tend-Q intervals, reflecting the electrical and mechanical diastole (240+/-78ms and 276+/-108ms vs. 373+/-110ms, p<0.0001; 409+/-85ms and 447+/-115ms vs. 526+/-119ms, p<0.0001). The PQ-interval was significantly longer in the patient group (169+/-28ms and 171+/-38ms vs. 153+/-22ms, p<0.005). After adjusting for possible confounders, a novel index (Tend-P/[PQxAge]) showed a high performance for the recognition of DD, stayed robust in the validation group (sensitivity 82%, specificity 93%, positive predictive value 93%, negative predictive value 82%, accuracy 88%) and proved a substantial added value when combined with the indexed left atrial volume (LAESVI, sensitivity 90%, specificity 92%, positive predictive value 95%, negative predictive value 86%, accuracy 91%). CONCLUSIONS: A novel electrocardiographic index Tend-P/(PQxAge) demonstrates a high diagnostic accuracy for the diagnosis of DD and yields a substantial added value when combined with the LAESVI
    corecore