26 research outputs found

    Binary and Millisecond Pulsars at the New Millennium

    Get PDF
    We review the properties and applications of binary and millisecond pulsars. Our knowledge of these exciting objects has greatly increased in recent years, mainly due to successful surveys which have brought the known pulsar population to over 1300. There are now 56 binary and millisecond pulsars in the Galactic disk and a further 47 in globular clusters. This review is concerned primarily with the results and spin-offs from these surveys which are of particular interest to the relativity community.Comment: 59 pages, 26 figures, 5 tables. Accepted for publication in Living Reviews in Relativity (http://www.livingreviews.org

    Binary and Millisecond Pulsars

    Full text link
    We review the main properties, demographics and applications of binary and millisecond radio pulsars. Our knowledge of these exciting objects has greatly increased in recent years, mainly due to successful surveys which have brought the known pulsar population to over 1700. There are now 80 binary and millisecond pulsars associated with the disk of our Galaxy, and a further 103 pulsars in 24 of the Galactic globular clusters. Recent highlights have been the discovery of the first ever double pulsar system and a recent flurry of discoveries in globular clusters, in particular Terzan 5.Comment: 77 pages, 30 figures, available on-line at http://www.livingreviews.org/lrr-2005-

    Comparison of Continuous and Filter-Based Carbon Measurements at the Fresno Supersite

    Get PDF
    Results from six continuous and semicontinuous black carbon (BC) and elemental carbon (EC) measurement methods are compared for ambient samples collected from December 2003 through November 2004 at the Fresno Supersite in California. Instruments included a multi-angle absorption photometer (MAAP; wavelength 670 nm); a dual-wavelength (wavelengths 370 and 880 nm) aethalometer; seven-color (wavelengths 370, 470, 520, 590, 660, 880, and 950 nm) aethalometers; the Sunset Laboratory carbon aerosol analysis field instrument; a photoacoustic light absorption analyzer (wavelength 1047 nm); and the R&P 5400 ambient carbon particulate monitor. All of these acquired BC or EC measurements over periods of 1 min to 1 hr. Twenty-fourhour integrated filter samples were also acquired and analyzed by the Interagency Monitoring of Protected Visual Environments (IMPROVE) thermal/optical reflectance carbon analysis protocol. Site-specific mass absorption efficiencies estimated by comparing light absorption with IMPROVE EC concentrations were 5.5m2/g for the MAAP, 10 m2/g for the aethalometer at a wavelength of 880 nm, and 2.3 m2/g for the photoacoustic analyzer; these differed from the default efficiencies of 6.5, 16.6, and 5m2/g, respectively. Scaling absorption by inverse wavelength did not provide equivalent light absorption coefficients among the instruments for the Fresno aerosol measurements. Ratios of light absorption at 370 nm to those at 880 nm from the aethalometer were nearly twice as high in winter as in summer. This is consistent with wintertime contributions from vehicle exhaust and from residential wood combustion, which is believed to absorb more shorter-wavelength light. To reconcile BC and EC measurements obtained by different methods, a better understanding is needed of the wavelength dependence of light-absorption and mass-absorption efficiencies and how they vary with different aerosol composition

    Separation of Brown Carbon from Black Carbon for IMPROVE and Chemical Speciation Network PM2.5 Samples

    Full text link
    The replacement of the Desert Research Institute (DRI) model 2001 with model 2015 thermal/optical analyzers (TOAs) results in continuity of the long-term organic carbon (OC) and elemental carbon (EC) database, and it adds optical information with no additional carbon analysis effort. The value of multiwavelength light attenuation is that light absorption due to black carbon (BC) can be separated from that of brown carbon (BrC), with subsequent attribution to known sources such as biomass burning and secondary organic aerosols. There is evidence of filter loading effects for the 25% of all samples with the highest EC concentrations based on the ratio of light attenuation to EC. Loading corrections similar to those used for the seven-wavelength aethalometer need to be investigated. On average, nonurban Interagency Monitoring of PROtected Visual Environments (IMPROVE) samples show higher BrC fractions of short-wavelength absorption than urban Chemical Speciation Network (CSN) samples, owing to greater influence from biomass burning and aged aerosols, as well as to higher primary BC contributions from engine exhaust at urban sites. Sequential samples taken during an Everglades National Park wildfire demonstrate the evolution from flaming to smoldering combustion, with the BrC fraction increasing as smoldering begins to dominate the fire event. Implications: The inclusion of seven wavelengths in thermal/optical carbon analysis of speciated PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 μm) samples allows contributions from biomass burning and secondary organic aerosols to be estimated. This separation is useful for evaluating control strategy effectiveness, identifying exceptional events, and determining natural visibility conditions

    Quality assurance and quality control for thermal/optical analysis of aerosol samples for organic and elemental carbon

    No full text
    Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (&lt; 4 A degrees C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (&lt; 100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.</p

    Optical Calibration and Equivalence of a Multiwavelength Thermal/Optical Carbon Analyzer

    Full text link
    Organic and elemental carbon (OC and EC) are operationally-defined by the measurement process, so long-term trends may be interrupted with instrumentation changes. A modification to the U.S. IMPROVE carbon analysis protocol and hardware is examined that replaces the 633 nm laser light used for OC charring adjustments with seven wavelengths ranging from 405 to 980 nm, including one at 635 nm. Reflectance (R) and Transmittance (T) values for each wavelength are made traceable to primary standards through transfer standards consisting of a range of aerosol deposits on filter media similar to that of the analyzed samples. R and T values are assigned to these filters using a UV/VIS spectrometer calibrated with these standards. Using ambient and source (e.g., diesel exhaust, flaming biomass, and smoldering biomass) samples, it is demonstrated that R and T calibration is independent of the sample type. Total carbon (TC), OC, and EC comparisons with the earlier hardware design for urban- and non-urban samples demonstrate equivalence, within precisions derived from replicate analyses, for the 633 nm and 635 nm wavelengths. Several uses of the additional multiwavelength information are identified, including: 1) ground-truthing of multi-spectral remote sensors; 2) improving estimates of the Earth’s radiation balance; 3) associating specific organic compounds with their light absorption properties; and 4) appropriating sources of black and brown carbon
    corecore