43 research outputs found

    Fixed low-dose ultrasound-assisted catheter-directed thrombolysis for intermediate and high-risk pulmonary embolism

    Get PDF
    Aims No standardized local thrombolysis regimen exists for the treatment of pulmonary embolism (PE). We retrospectively investigated efficacy and safety of fixed low-dose ultrasound-assisted catheter-directed thrombolysis (USAT) for intermediate- and high-risk PE. Methods and results Fifty-two patients (65 ± 14 years) of whom 14 had high-risk PE (troponin positive in all) and 38 intermediate-risk PE (troponin positive in 91%) were treated with intravenous unfractionated heparin and USAT using 10 mg of recombinant tissue plasminogen activator per device over the course of 15 h. Bilateral USAT was performed in 83% of patients. During 3-month follow-up, two [3.8%; 95% confidence interval (CI) 0.5-13%] patients died (one from cardiogenic shock and one from recurrent PE). Major non-fatal bleeding occurred in two (3.8%; 95% CI, 0.5-13%) patients: one intrathoracic bleeding after cardiopulmonary resuscitation requiring transfusion, one intrapulmonary bleeding requiring lobectomy. Mean pulmonary artery pressure decreased from 37 ± 9 mmHg at baseline to 25 ± 8 mmHg at 15 h (P < 0.001) and cardiac index increased from 2.0 ± 0.7 to 2.7 ± 0.9 L/min/m2 (P < 0.001). Echocardiographic right-to-left ventricular end-diastolic dimension ratio decreased from 1.42 ± 0.21 at baseline to 1.06 ± 0.23 at 24 h (n = 21; P < 0.001). The greatest haemodynamic benefit from USAT was found in patients with high-risk PE and in those with symptom duration < 14 days. Conclusion A standardized catheter intervention approach using fixed low-dose USAT for the treatment of intermediate- and high-risk PE was associated with rapid improvement in haemodynamic parameters and low rates of bleeding complications and mortalit

    Erectile dysfunction: role of computed tomography cavernosography in the diagnosis and treatment planning of venous leak.

    Get PDF
    BACKGROUND Venous leak appears to be the most common cause of vasculogenic erectile dysfunction (ED), which can be treated with venous embolization. Traditionally, conventional cavernosography was used for the diagnosis and treatment planning of venous leak. Recently, computed tomography (CT) cavernosography was introduced as a novel cross-sectional imaging method proposed to be advantageous over conventional cavernosography. We created a novel management algorithm for diagnosing venous leak including CT cavernosography as an imaging modality. In order to provide a broader basis for our management algorithm, a systematic literature review was conducted. MAIN BODY In this article we systematically review relevant literature on using CT cavernosography for the diagnosis and treatment planning in ED patients with venous leak following the PRISMA selection process. Nine full-text articles were included in the review and assigned a level of evidence grade (all grade II). Two studies (2/9) compared the results of conventional cavernosography with those of CT cavernosography which was superior for site-specific venous leak identification (19.4% vs. 100%, respectively). CT cavernosography is a more detailed imaging method that is faster to perform, exposes the patient to less radiation, and requires less contrast material. In one study (1/9), CT cavernosography was used for diagnostic purposes only. Eight studies (8/9) cover both, diagnostic imaging and treatment planning including embolization (1/9) and sclerotherapy (2/9) of venous leak in patients with venogenic ED. Three studies (3/9) describe anatomical venous leak classifications that were established based on CT cavernosography findings for accurate mapping of superficial and/or deep venous leak and identification of mixed or more complex forms of venous leak present in up to 84% of patients. In addition to treatment planning, one study (1/9) used CT cavernosography also for follow-up imaging post treatment. CONCLUSION CT cavernosography is superior to conventional cavernosography for diagnosis and treatment planning in patients with ED caused by venous leak (grade II levels of evidence). Consequently, CT cavernosography should be included in management algorithms for ED patients with suspected venous leak

    Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study

    Get PDF
    Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula

    In search of optimal compression therapy for venous leg ulcers: a meta-analysis of studies comparing diverse [corrected] bandages with specifically designed stockings

    Get PDF
    OBJECTIVE: In search of an optimal compression therapy for venous leg ulcers, a systematic review and meta-analysis was performed of randomized controlled trials (RCT) comparing compression systems based on stockings (MCS) with divers bandages. METHODS: RCT were retrieved from six sources and reviewed independently. The primary endpoint, completion of healing within a defined time frame, and the secondary endpoints, time to healing, and pain were entered into a meta-analysis using the tools of the Cochrane Collaboration. Additional subjective endpoints were summarized. RESULTS: Eight RCT (published 1985-2008) fulfilled the predefined criteria. Data presentation was adequate and showed moderate heterogeneity. The studies included 692 patients (21-178/study, mean age 61 years, 56% women). Analyzed were 688 ulcerated legs, present for 1 week to 9 years, sizing 1 to 210 cm(2). The observation period ranged from 12 to 78 weeks. Patient and ulcer characteristics were evenly distributed in three studies, favored the stocking groups in four, and the bandage group in one. Data on the pressure exerted by stockings and bandages were reported in seven and two studies, amounting to 31-56 and 27-49 mm Hg, respectively. The proportion of ulcers healed was greater with stockings than with bandages (62.7% vs 46.6%; P < .00001). The average time to healing (seven studies, 535 patients) was 3 weeks shorter with stockings (P = .0002). In no study performed bandages better than MCS. Pain was assessed in three studies (219 patients) revealing an important advantage of stockings (P < .0001). Other subjective parameters and issues of nursing revealed an advantage of MCS as well. CONCLUSIONS: Leg compression with stockings is clearly better than compression with bandages, has a positive impact on pain, and is easier to use

    Bioengineered valves for the venous circulation

    Full text link
    Introduction: Chronic insufficiency of lower extremity venous valves represents a frequent structural disorder of the vascular system being responsible for a substantial global disease load. While in the field of superficial valve insufficiency surgical as well as endoluminal interventions represent good therapeutic options with high rates of complete remission of symptoms, only limited options exist in the field of deep venous reflux today. Bioengineered, autologous cell-based, endothelialized valve constructs may open up new therapeutic options in these patients, potentially offering novel treatment options in cases with severe insufficiency of deep venous segments in the future. Areas covered: This review summarizes previous reports focusing on venous valve replacement and bioengineering, also including first preclinical in vivo studies and first clinical trials in patients. In particular, the aspects of current technical and medical limitations of venous valve bioengineering approaches preventing clinical translation and potential solutions by upcoming technologies will be discussed as part of this review. Expert commentary: Bioengineered replacement valves may open up novel options in the treatment of venous valve disease in defined patient groups in the future. However, preventing thromboembolic complications will remain the bottle-neck for clinical translation of the technologies involved

    Ease of Application of Medical Compression-stocking Systems for the Treatment of Venous Ulcers

    Get PDF
    OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing

    Neurological complications of sclerotherapy for varicose veins

    Get PDF
    Sclerotherapy has been shown to be an effective and increasingly popular therapeutic strategy for the treatment of varicose veins. However, recent reports of serious side effects, including cerebrovascular accidents (CVA) and transient ischemic attacks (TIA), as well as speech and visual disturbances, have caused serious concern regarding its use. This review evaluated the reported incidences of neurological side effects associated with the use of sclerotherapy

    Pain in the aftermath of minimal invasive treatment for unilateral incompetence of the great saphenous vein.

    No full text
    OBJECTIVES Assessment of postprocedural pain after minimal invasive treatment of unilateral incompetence of the great saphenous vein. METHODS A total of 85 patients treated with endovenous laser ablation (1470 nm) in combination with foam sclerotherapy and evulsions reported postprocedural pain on a visual analogue scale (0-10) during 28 days after treatment. RESULTS A mean pain reduction from 3.9 on the first postinterventional day to 0.3 was noted during the observation time. After 28 days, 7% of patients had a visual analogue scale >1. Higher body mass index was strongly associated with more pain during the whole follow-up period (p < 0.01). Higher energy application per cm vein and greater great saphenous vein diameter showed more pain in the first week. Other factors like clinical stage CEAP classification, combination of laser with avulsions and/or sclerotherapy, season of treatment timepoint, and age or sex did not influence postinterventional pain course. CONCLUSION Higher body mass index and higher energy application per cm are associated with more postprocedural pain after endovenous laser ablation
    corecore