    Testing mechanical chest compression devices of different design for their suitability for prehospital patient transport - a simulator-based study

    Get PDF
    BACKGROUND Mechanical chest compression (mCPR) offers advantages during transport under cardiopulmonary resuscitation. Little is known how devices of different design perform en-route. Aim of the study was to measure performance of mCPR devices of different construction-design during ground-based pre-hospital transport. METHODS We tested animax mono (AM), autopulse (AP), corpuls cpr (CC) and LUCAS2 (L2). The route had 6 stages (transport on soft stretcher or gurney involving a stairwell, trips with turntable ladder, rescue basket and ambulance including loading/unloading). Stationary mCPR with the respective device served as control. A four-person team carried an intubated and bag-ventilated mannequin under mCPR to assess device-stability (displacement, pressure point correctness), compliance with 2015 ERC guideline criteria for high-quality chest compressions (frequency, proportion of recommended pressure depth and compression-ventilation ratio) and user satisfaction (by standardized questionnaire). RESULTS All devices performed comparable to stationary use. Displacement rates ranged from 83% (AM) to 11% (L2). Two incorrect pressure points occurred over 15,962 compressions (0.013%). Guideline-compliant pressure depth was > 90% in all devices. Electrically powered devices showed constant frequencies while muscle-powered AM showed more variability (median 100/min, interquartile range 9). Although physical effort of AM use was comparable (median 4.0 vs. 4.5 on visual scale up to 10), participants preferred electrical devices. CONCLUSION All devices showed good to very good performance although device-stability, guideline compliance and user satisfaction varied by design. Our results underline the importance to check stability and connection to patient under transport

    Combined recurrent laryngeal nerve monitoring and one-lung ventilation using the EZ-Blocker and an electromyographic endotracheal tube

    Get PDF
    Background Intraoperative neuromuscular monitoring (IONM) is a widespread procedure to identify and protect the recurrent laryngeal nerve (RLN) during thyroid surgery. However, for left thoracic surgery with high risk of RLN injury, both reliable recurrent laryngeal nerve monitoring and one-lung ventilation could interfere. Methods In this prospective study, a new method for IONM during one-lung ventilation combining RLN monitoring with an electromyographic (EMG) endotracheal tube (ETT) and lung separation using the EZ-Blocker (EZB) is described and its clinical feasibility and effectiveness were assessed. Results A total of 14 patients undergoing left upper lobe surgery and left upper mediastinal lymph node dissection were enrolled. The EZB was introduced and positioned without any problems and sufficient lung collapse was achieved in all patients. No tracheobronchial injuries or immediate complications occurred. A stable EMG signal was present in all patients and no RLN palsy and no negative side effects of the NIM EMG ETT or the EZB were observed postoperatively. Conclusions The described method is technically feasible, easy to apply and save. It provides both reliable IONM and independent lung separation for optimal surgical exposure. The combined use of the EZB and the NIM EMG ETT might reduce the risk for RLN palsy and impaired lung separation during left thoracic surgery with high risk for RLN injury

    EuReCa ONE—27 Nations, ONE Europe, ONE Registry A prospective one month analysis of out-of-hospital cardiac arrest outcomes in 27 countries in Europe

    Get PDF
    AbstractIntroductionThe aim of the EuReCa ONE study was to determine the incidence, process, and outcome for out of hospital cardiac arrest (OHCA) throughout Europe.MethodsThis was an international, prospective, multi-centre one-month study. Patients who suffered an OHCA during October 2014 who were attended and/or treated by an Emergency Medical Service (EMS) were eligible for inclusion in the study. Data were extracted from national, regional or local registries.ResultsData on 10,682 confirmed OHCAs from 248 regions in 27 countries, covering an estimated population of 174 million. In 7146 (66%) cases, CPR was started by a bystander or by the EMS. The incidence of CPR attempts ranged from 19.0 to 104.0 per 100,000 population per year. 1735 had ROSC on arrival at hospital (25.2%), Overall, 662/6414 (10.3%) in all cases with CPR attempted survived for at least 30 days or to hospital discharge.ConclusionThe results of EuReCa ONE highlight that OHCA is still a major public health problem accounting for a substantial number of deaths in Europe.EuReCa ONE very clearly demonstrates marked differences in the processes for data collection and reported outcomes following OHCA all over Europe. Using these data and analyses, different countries, regions, systems, and concepts can benchmark themselves and may learn from each other to further improve survival following one of our major health care events

    Well-being and PTSD in German emergency medical services - A nationwide cross-sectional survey.

    No full text
    BackgroundEmergency medical service (EMS) can be a burdensome occupational field, and employees can be confronted with traumatizing events. Posttraumatic stress disorder (PTSD) and depression rates among paramedics are considered higher than those in the general population. In the German setting of a physician-based EMS system, the literature provides little data on PTSD or non-PTSD-related mental health or on the correlation between PTSD and well-being.MethodsThe study collected data through a nationwide cross-sectional questionnaire survey of the German EMS. Next to gathering sociodemographic data, it used the 5-item World Health Organization Well-Being Index (WHO-5) and the Short Screening Scale for the DSM-IV-PTSD to assess well-being and identify indicators of depression and PTSD.ResultsA total of 2,731 paramedics and emergency physicians participated in the survey; 2,684 questionnaires were submitted to analysis. The average WHO-5 score was 53.15%. A total of 43.4% of participants screened positive for possible depression, as indicated by a WHO-5 score below 50%. Female gender, older age, higher total years spent working in EMS and increased body mass index were significantly correlated with lower well-being. A total of 5.4% of respondents had a positive PTSD screening result. In particular, older employees were significantly more likely to test positive for PTSD (12.2% of those over 50 years, compared to 2.8% of those under 30 years). Positive PTSD screening results were associated with significantly lower well-being. Over an average period of 1 year, the paramedics reported perceiving a median of 2 emergency missions as mentally distressing.ConclusionLow well-being and PTSD seem to be relevant experiences among German EMS despite their perception of low numbers of emergency responses as mentally distressing. Paramedics who have been diagnosed with PTSD should be investigated for depression and vice versa, as correlations in both directions exist. Special attention should be paid to older employees, who have significantly lower well-being and higher PTSD rates compared to younger employees

    A retropharyngeal-mediastinal hematoma with supraglottic and tracheal obstruction: The role of multidisciplinary airway management

    No full text
    A 77-year-old man suffered hypoxemic cardiac arrest by supraglottic and tracheal airway obstruction in the emergency department. A previously unknown cervical fracture had caused a traumatic retropharyngeal-mediastinal hematoma. A lifesaving surgical emergency tracheostomy succeeded. Supraglottic and tracheal obstruction by a retropharyngeal-mediastinal hematoma with successful resuscitation via emergency tracheostomy after hypoxemic cardiac arrest has never been reported in a context of trauma. This clinically demanding case outlines the need for multidisciplinary airway management systems with continuous training and well-implemented guidelines. Only multidisciplinary staff preparedness and readily available equipments for the unanticipated difficult airway solved the catastrophic clinical situation

    Primary mass casualty incident triage: evidence for the benefit of yearly brief re-training from a simulation study

    Get PDF
    Abstract Background Triage is a mainstay of early mass casualty incident (MCI) management. Standardized triage protocols aim at providing valid and reproducible results and, thus, improve triage quality. To date, there is little data supporting the extent and content of training and re-training on using such triage protocols within the Emergency Medical Services (EMS). The study objective was to assess the decline in triage skills indicating a minimum time interval for re-training. In addition, the effect of a one-hour repeating lesson on triage quality was analyzed. Methods A dummy based trial on primary MCI triage with yearly follow-up after initial training using the ASAV algorithm (Amberg-Schwandorf Algorithm for Primary Triage) was undertaken. Triage was assessed concerning accuracy, sensitivity, specificity, over-triage, under-triage, time requirement, and a comprehensive performance measure. A subgroup analysis of professional paramedics was made. Results Nine hundred ninety triage procedures performed by 51 providers were analyzed. At 1 year after initial training, triage accuracy and overall performance dropped significantly. Professional paramedic’s rate of correctly assigned triage categories deteriorated from 84 to 71%, and the overall performance score decreased from 95 to 90 points (maximum = 100). The observed decline in triage performance at 1 year after education made it necessary to conduct re-training. A brief didactic lecture of 45 min duration increased accuracy to 88% and the overall performance measure to 97. Conclusions To improve disaster preparedness, triage skills should be refreshed yearly by a brief re-education of all EMS providers

    The EZ-blocker for one-lung ventilation in patients undergoing thoracic surgery: clinical applications and experience in 100 cases in a routine clinical setting

    No full text
    Abstract Background In certain clinical situations the insertion of a double-lumen tube (DLT) for one-lung ventilation (OLV) is not feasible or unfavorable. In these cases, the EZ-Blocker (EZB) may serve as an alternative. The aim of our analysis was to report on the clinical applications and our experience with the EZB for one-lung ventilation in 100 patients undergoing thoracic surgery. Methods All anesthetic records from patients older than 18 years of age undergoing general anesthesia in the department of thoracic surgery with intraoperative use of an EZB for OLV at the University Hospital of Erlangen in four consecutive years were analyzed retrospectively. Results Most frequently, EZB was used in difficult airway (27%) and for surgical procedures with high risk for left recurrent laryngeal nerve injury (21%), followed by application in intubated (12%) or tracheostomized (11%) patients. 11% of the patients had an increased risk of gastric regurgitation. Almost all EZBs were placed free of complications (99%). Clinically sufficient lung collapse was achieved in all patients. No serious airway injuries or immediate complications were documented. Conclusions The EZB is an efficient, easy-to-use and safe airway device and enables OLV in several clinical situations, when conventional DLTs are not feasible or less favorable. Three major applications were depicted from the data: expected difficult airway, surgical procedures with necessity of intraoperative recurrent laryngeal nerve monitoring and already intubated or tracheostomized patients