429 research outputs found

    Effect of metal clusters on the swelling of gold-fluorocarbon-polymer composite films

    Full text link
    We have investigated the phenomenon of swelling due to acetone diffusion in fluorocarbon polymer films doped with different gold concentrations below the percolation threshold. The presence of the gold clusters in the polymer is shown to improve the mixing between the fluorocarbon polymer and the acetone, which is not a good solvent for this kind of polymers. In order to explain the experimental results the stoichiometry and the morphology of the polymer--metal system have been studied and a modified version of the Flory--Huggins model has been developed

    Overview of recent developments in organic thin-film transistor sensor technology

    Get PDF
    Bio and chemical sensing represents one of the most attractive applications of organic electronics and of Organic Thin Film Transistors (OTFTs) in particular. The implementation of miniaturized portable systems for the detection of chemical analytes as well as of biological species, is still a challenge for the sensors’ community. In this respect OTFTs appear as a new class of sensors able, in principle, to overcome some of the commercial sensors drawbacks. As far as volatile analytes are concerned, commercially available sensing systems, such as metal oxide based chemi-resistors, offer great stability but rather poor selectivity. In spite of the improved selectivity offered by organic chemi-resistors the reliability of such devices is not yet satisfactorily proven. On the other hand, complex odors recognition, but also explosives or pathogen bacteria detection are currently being addressed by sensor array systems, called “e-noses”, that try to mimic the mammalian olfactory system. Even though potentially very effective, this technology has not yet reached the performance level required by the market mostly because miniaturization and cost effective production issues. OTFT sensors can offer the advantage of room temperature operation and deliver high repeatable responses. Beside, they show very good selectivity properties. In fact, they implement organic active layers, which behave as sensing layers as well. This improves OTFTs sensitivity towards different chemical and biological analytes as organic materials can be properly chemically tailored to achieve differential detection and potentially even discrimination of biological species. In addition to this, OTFTs are also able to offer the unique advantages of a multi-parametric response and a gate bias enhanced sensitivity. Recently thin dielectric low-voltage OTFTs have also been demonstrated. Their implementation in low power consumption devices has attracted the attention of the organic electronic community. But such low power transistors have also a great potential in sensing applications specifically those performed in a liquid environment. In fact, low-voltage OTFTs have been recently demonstrated to deliver reliable responses even when operated in water for hundreds of measurement cycles. This open new perspectives in the field of cheap, low-power and mass-produced aqueous sensors

    Assessment of gold bio-functionalization for wide-interface biosensing platforms

    Get PDF
    The continuous improvement of the technical potential of bioelectronic devices for biosensing applications will provide clinicians with a reliable tool for biomarker quantification down to the single molecule. Eventually, physicians will be able to identify the very moment at which the illness state begins, with a terrific impact on the quality of life along with a reduction of health care expenses. However, in clinical practice, to gather enough information to formulate a diagnosis, multiple biomarkers are normally quantified from the same biological sample simultaneously. Therefore, it is critically important to translate lab-based bioelectronic devices based on electrolyte gated thin-film transistor technology into a cost-effective portable multiplexing array prototype. In this perspective, the assessment of cost-effective manufacturability represents a crucial step, with specific regard to the optimization of the bio-functionalization protocol of the transistor gate module. Hence, we have assessed, using surface plasmon resonance technique, a sustainable and reliable cost-effective process to successfully bio-functionalize a gold surface, suitable as gate electrode for wide-field bioelectronic sensors. The bio-functionalization process herein investigated allows to reduce the biorecognition element concentration to one-tenth, drastically impacting the manufacturing costs while retaining high analytical performance

    Surface plasmon resonance assay for label-free and selective detection of hiv-1 p24 protein

    Get PDF
    The early detection of the human immunodeficiency virus (HIV) is of paramount importance to achieve efficient therapeutic treatment and limit the disease spreading. In this perspective, the assessment of biosensing assay for the HIV-1 p24 capsid protein plays a pivotal role in the timely and selective detection of HIV infections. In this study, multi-parameter-SPR has been used to develop a reliable and label-free detection method for HIV-1 p24 protein. Remarkably, both physical and chemical immobilization of mouse monoclonal antibodies against HIV-1 p24 on the SPR gold detecting surface have been characterized for the first time. The two immobilization techniques returned a capturing antibody surface coverage as high as (7.5 ± 0.3) × 1011 molecule/cm2 and (2.4 ± 0.6) × 1011 molecule/cm2, respectively. However, the covalent binding of the capturing antibodies through a mixed self-assembled monolayer (SAM) of alkanethiols led to a doubling of the p24 binding signal. Moreover, from the modeling of the dose-response curve, an equilibrium dissociation constant KD of 5.30 × 10−9 M was computed for the assay performed on the SAM modified surface compared to a much larger KD of 7.46 × 10−5 M extracted for the physisorbed antibodies. The chemically modified system was also characterized in terms of sensitivity and selectivity, reaching a limit of detection of (4.1 ± 0.5) nM and an unprecedented selectivity ratio of 0.02

    Enhancing the Sensitivity of Biotinylated Surfaces by Tailoring the Design of the Mixed Self-Assembled Monolayer Synthesis

    Get PDF
    Thiolated self-assembled monolayers (SAMs) are typically used to anchor on a gold surface biomolecules serving as recognition elements for biosensor applications. Here, the design and synthesis of N-(2-hydroxyethyl)-3-mercaptopropanamide (NMPA) in biotinylated mixed SAMs is proposed as an alternative strategy with respect to on-site multistep functionalization of SAMs prepared from solutions of commercially available thiols. In this study, the mixed SAM deposited from a 10:1 solution of 3-mercaptopropionic acid (3MPA) and 11-mercaptoundecanoic acid (11MUA) is compared to that resulting from a 10:1 solution of NMPA:11MUA. To this end, surface plasmon resonance (SPR) and attenuated total reflectance infrared (ATR-IR) experiments have been carried out on both mixed SAMs after biotinylation. The study demonstrated how the fine tuning of the SAM features impacts directly on both the biofunctionalization steps, i.e., the biotin anchoring, and the biorecognition properties evaluated upon exposure to streptavidin analyte. Higher affinity for the target analyte with reduced nonspecific binding and lower detection limit has been demonstrated when NMPA is chosen as the more abundant starting thiol. Molecular dynamics simulations complemented the experimental findings providing a molecular rationale behind the performance of the biotinylated mixed SAMs. The present study confirms the importance of the functionalization design for the development of a highly performing biosensor

    Temperature dependence of the charge carrier mobility in gated quasi-one-dimensional systems

    Full text link
    The many-body Monte Carlo method is used to evaluate the frequency dependent conductivity and the average mobility of a system of hopping charges, electronic or ionic on a one-dimensional chain or channel of finite length. Two cases are considered: the chain is connected to electrodes and in the other case the chain is confined giving zero dc conduction. The concentration of charge is varied using a gate electrode. At low temperatures and with the presence of an injection barrier, the mobility is an oscillatory function of density. This is due to the phenomenon of charge density pinning. Mobility changes occur due to the co-operative pinning and unpinning of the distribution. At high temperatures, we find that the electron-electron interaction reduces the mobility monotonically with density, but perhaps not as much as one might intuitively expect because the path summation favour the in-phase contributions to the mobility, i.e. the sequential paths in which the carriers have to wait for the one in front to exit and so on. The carrier interactions produce a frequency dependent mobility which is of the same order as the change in the dc mobility with density, i.e. it is a comparably weak effect. However, when combined with an injection barrier or intrinsic disorder, the interactions reduce the free volume and amplify disorder by making it non-local and this can explain the too early onset of frequency dependence in the conductivity of some high mobility quasi-one-dimensional organic materials.Comment: 9 pages, 8 figures, to be published in Physical Review

    A large-area organic transistor with 3D-printed sensing gate for noninvasive single-molecule detection of pancreatic mucinous cyst markers

    Get PDF
    Early diagnosis in a premalignant (or pre-invasive) state represents the only chance for cure in neoplastic diseases such as pancreatic-biliary cancer, which are otherwise detected at later stages and can only be treated using palliative approaches, with no hope for a cure. Screening methods for the purpose of secondary prevention are not yet available for these cancers. Current diagnostic methods mostly rely on imaging techniques and conventional cytopathology, but they do not display adequate sensitivity to allow valid early diagnosis. Next-generation sequencing can be used to detect DNA markers down to the physical limit; however, this assay requires labeling and is time-consuming. The additional determination of a protein marker that is a predictor of aggressive behavior is a promising innovative approach, which holds the potential to improve diagnostic accuracy. Moreover, the possibility to detect biomarkers in blood serum offers the advantage of a noninvasive diagnosis. In this study, both the DNA and protein markers of pancreatic mucinous cysts were analyzed in human blood serum down to the single-molecule limit using the SiMoT (single-molecule assay with a large transistor) platform. The SiMoT device proposed herein, which exploits an inkjet-printed organic semiconductor on plastic foil, comprises an innovative 3D-printed sensing gate module, consisting of a truncated cone that protrudes from a plastic substrate and is compatible with standard ELISA wells. This 3D gate concept adds tremendous control over the biosensing system stability, along with minimal consumption of the capturing molecules and body fluid samples. The 3D sensing gate modules were extensively characterized from both a material and electrical perspective, successfully proving their suitability as detection interfaces for biosensing applications. KRAS and MUC1 target molecules were successfully analyzed in diluted human blood serum with the 3D sensing gate functionalized with b-KRAS and anti-MUC1, achieving a limit of detection of 10 zM and 40 zM, respectively. These limits of detection correspond to (1 ± 1) KRAS and (2 ± 1) MUC1 molecules in the 100 ΌL serum sample volume. This study provides a promising application of the 3D SiMoT platform, potentially facilitating the timely, noninvasive, and reliable identification of pancreatic cancer precursor cysts

    Coulomb-blockade transport in single-crystal organic thin-film transistors

    Get PDF
    Coulomb-blockade transport—whereby the Coulomb interaction between electrons can prohibit their transport around a circuit—occurs in systems in which both the tunnel resistance, RT, between neighbouring sites is large (»h/e2) and the charging energy, EC (EC = e2/2C, where C is the capacitance of the site), of an excess electron on a site is large compared to kT. (Here e is the charge of an electron, k is Boltzmann's constant, and h is Planck's constant.) The nature of the individual sites—metallic, superconducting, semiconducting or quantum dot—is to first order irrelevant for this phenomenon to be observed. Coulomb blockade has also been observed in two-dimensional arrays of normal-metal tunnel junctions, but the relatively large capacitances of these micrometre-sized metal islands results in a small charging energy, and so the effect can be seen only at extremely low temperatures. Here we demonstrate that organic thin-film transistors based on highly ordered molecular materials can, to first order, also be considered as an array of sites separated by tunnel resistances. And as a result of the sub-nanometre sizes of the sites (the individual molecules), and hence their small capacitances, the charging energy dominates at room temperature. Conductivity measurements as a function of both gate bias and temperature reveal the presence of thermally activated transport, consistent with the conventional model of Coulomb blockade.
    • 

    corecore