6,107 research outputs found
Langley Mach 4 scramjet test facility
An engine test facility was constructed at the NASA Langley Research Center in support of a supersonic combustion ramjet (scramjet) technology development program. Hydrogen combustion in air with oxygen replenishment provides simulated air at Mach 4 flight velocity, pressure, and true total temperature for an altitude range from 57,000 to 86,000 feet. A facility nozzle with a 13 in square exit produces a Mach 3.5 free jet flow for engine propulsion tests. The facility is described and calibration results are presented which demonstrate the suitability of the test flow for conducting scramjet engine research
Global surface slopes and roughness of the Moon from the Lunar Orbiter Laser Altimeter
The acquisition of new global elevation data from the Lunar Orbiter Laser Altimeter, carried on the Lunar Reconnaissance Orbiter, permits quantification of the surface roughness properties of the Moon at unprecedented scales and resolution. We map lunar surface roughness using a range of parameters: median absolute slope, both directional (along-track) and bidirectional (in two dimensions); median differential slope; and Hurst exponent, over baselines ranging from ~17 m to ~2.7 km. We find that the lunar highlands and the mare plains show vastly different roughness properties, with subtler variations within mare and highlands. Most of the surface exhibits fractal-like behavior, with a single or two different Hurst exponents over the given baseline range; when a transition exists, it typically occurs near the 1 km baseline, indicating a significant characteristic spatial scale for competing surface processes. The Hurst exponent is high within the lunar highlands, with a median value of 0.95, and lower in the maria (with a median value of 0.76). The median differential slope is a powerful tool for discriminating between roughness units and is useful in characterizing, among other things, the ejecta surrounding large basins, particularly Orientale, as well as the ray systems surrounding young, Copernican-age craters. In addition, it allows a quantitative exploration on mare surfaces of the evolution of surface roughness with age
The role of epidemiology in food safety issues in governmental decisions and actions
Since the President announced the Food Safety Initiative in 1997. numerous multi-agency initiatives, work groups, and committees have been established. Each group is struggling to gather science-based data to make regulatory and policy decisions and to guide strategic planning efforts. In many cases. there are little or no data available. Innovative and creative approaches are needed to address multi-disciplinary strategic goals in food safety and to fill knowledge gaps
Evaluation of the LEP Centre-of-Mass Energy Above the W-Pair Production Threshold
Knowledge of the centre-of-mass energy at LEP2 is of primary importance to
set the absolute energy scale for the measurement of the W-boson mass. The beam
energy above 80 GeV is derived from continuous measurements of the magnetic
bending field by 16 NMR probes situated in a number of the LEP dipoles. The
relationship between the fields measured by the probes and the beam energy is
calibrated against precise measurements of the average beam energy between 41
and 55 GeV made using the resonant depolarisation technique. The linearity of
the relationship is tested by comparing the fields measured by the probes with
the total bending field measured by a flux loop. This test results in the
largest contribution to the systematic uncertainty. Several further corrections
are applied to derive the the centre-of-mass energies at each interaction
point. In addition the centre-of-mass energy spread is evaluated. The beam
energy has been determined with a precision of 25 MeV for the data taken in
1997, corresponding to a relative precision of 2.7x10^{-4}. This is small in
comparison to the present uncertainty on the W mass measurement at LEP.
However, the ultimate statistical precision on the W mass with the full LEP2
data sample should be around 25 MeV, and a smaller uncertainty on the beam
energy is desirable. Prospects for improvements are outlined.Comment: 24 pages, 10 figures, Latex, epsfig; replaced by version accepted by
European Physical Journal
LAGEOS geodetic analysis-SL7.1
Laser ranging measurements to the LAGEOS satellite from 1976 through 1989 are related via geodetic and orbital theories to a variety of geodetic and geodynamic parameters. The SL7.1 analyses are explained of this data set including the estimation process for geodetic parameters such as Earth's gravitational constant (GM), those describing the Earth's elasticity properties (Love numbers), and the temporally varying geodetic parameters such as Earth's orientation (polar motion and Delta UT1) and tracking site horizontal tectonic motions. Descriptions of the reference systems, tectonic models, and adopted geodetic constants are provided; these are the framework within which the SL7.1 solution takes place. Estimates of temporal variations in non-conservative force parameters are included in these SL7.1 analyses as well as parameters describing the orbital states at monthly epochs. This information is useful in further refining models used to describe close-Earth satellite behavior. Estimates of intersite motions and individual tracking site motions computed through the network adjustment scheme are given. Tabulations of tracking site eccentricities, data summaries, estimated monthly orbital and force model parameters, polar motion, Earth rotation, and tracking station coordinate results are also provided
Calibration of centre-of-mass energies at LEP 2 for a precise measurement of the W boson mass
The determination of the centre-of-mass energies for all LEP 2 running is
presented. Accurate knowledge of these energies is of primary importance to set
the absolute energy scale for the measurement of the W boson mass. The beam
energy between 80 and 104 GeV is derived from continuous measurements of the
magnetic bending field by 16 NMR probes situated in a number of the LEP
dipoles. The relationship between the fields measured by the probes and the
beam energy is defined in the NMR model, which is calibrated against precise
measurements of the average beam energy between 41 and 61 GeV made using the
resonant depolarisation technique. The validity of the NMR model is verified by
three independent methods: the flux-loop, which is sensitive to the bending
field of all the dipoles of LEP; the spectrometer, which determines the energy
through measurements of the deflection of the beam in a magnet of known
integrated field; and an analysis of the variation of the synchrotron tune with
the total RF voltage. To obtain the centre-of-mass energies, corrections are
then applied to account for sources of bending field external to the dipoles,
and variations in the local beam energy at each interaction point. The relative
error on the centre-of-mass energy determination for the majority of LEP 2
running is 1.2 x 10^{-4}, which is sufficiently precise so as not to introduce
a dominant uncertainty on the W mass measurement.Comment: 79 pages, 45 figures, submitted to EPJ
Methods and Processes of Developing the Strengthening the Reporting of Observational Studies in Epidemiology â Veterinary (STROBE-Vet) Statement
BACKGROUND
Reporting of observational studies in veterinary research presents challenges that often are not addressed in published reporting guidelines.
OBJECTIVE
To develop an extension of the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement that addresses unique reporting requirements for observational studies in veterinary medicine related to health, production, welfare, and food safety.
DESIGN
Consensus meeting of experts.
SETTING
Mississauga, Canada.
PARTICIPANTS
Seventeen experts from North America, Europe, and Australia.
METHODS
Experts completed a pre-meeting survey about whether items in the STROBE statement should be modified or added to address unique issues related to observational studies in animal species with health, production, welfare, or food safety outcomes. During the meeting, each STROBE item was discussed to determine whether or not rewording was recommended and whether additions were warranted. Anonymous voting was used to determine consensus.
RESULTS
Six items required no modifications or additions. Modifications or additions were made to the STROBE items 1 (title and abstract), 3 (objectives), 5 (setting), 6 (participants), 7 (variables), 8 (data sources/measurement), 9 (bias), 10 (study size), 12 (statistical methods), 13 (participants), 14 (descriptive data), 15 (outcome data), 16 (main results), 17 (other analyses), 19 (limitations), and 22 (funding).
CONCLUSION
The methods and processes used were similar to those used for other extensions of the STROBE statement. The use of this STROBE statement extension should improve reporting of observational studies in veterinary research by recognizing unique features of observational studies involving food-producing and companion animals, products of animal origin, aquaculture, and wildlife
Implementation and Performance of the tau trigger in the ATLAS experiment
Triggering on hadronic taus at the LHC is a difficult task due to the high rate and occupancy of the events. On the other hand, the tau trigger increases the discovery potential of ATLAS in many physics channels, among others the Standard Model or SuperSymmetric Higgs (charged or neutrals) production. In order to cope with the rate and optimize the efficiency on important physics channels, the results of the current simulation studies indicate that the ATLAS tau trigger should be used either with relatively high transverse momentum thresholds alone, or with more relaxed threshold requirements in combination with other triggers, like the missing transverse energy trigger or a leptonic or jet trigger. In this contribution we describe the ATLAS tau trigger, and we present some of the current results from the simulation studies, focusing both on early physics and on physics at high luminosity
Determination of the Accuracy of Wire Position Sensors
An energy spectrometer has been installed in the LEP accelerator to determine the beam energy with a relative accuracy of 10-4. A precisely calibrated bending magnet is flanked by 6 beam position monitors (BPM). The beam energy is determined by measuring the deflection angle of the LEP beams and the integrated bending field. An accuracy of less than 10-6 m on the beam position is necessary to reach the desired accuracy on the LEP beam energy. Capacitive wire positioning sensors are used to determine the relative mounting stability of each BPM and to calibrate the beam position monitors. Two-dimensional sensors are attached to each side of every BPM support and provide a position measurement with respect to two stretched wires mounted on either side of the LEP beam pipe. The fixing points of each wire are monitored by additional reference sensors. The position information is digitised via a multiplexed high accuracy digital voltmeter and read out continuously during LEP operations. Wire position sensor accuracy was tested in the laboratory with a laser interferometer, while relative accuracy tests are performed in the LEP environment. Systematic effects of synchrotron radiation on the wire position sensor performance were studied
- âŠ