907 research outputs found

    Control System Design, Analysis, and Simulation of a Photovoltaic Inverter for Unbalanced Load Compensation in a Microgrid

    Get PDF
    This thesis presents a control scheme for a single-stage three-phase Photovoltaic (PV) converter with negative sequence load current compensation. In this thesis a dual virtual impedance active damping technique for an LCL filter is proposed to address the issue of LCL filter resonance. Both inverter-side current and the capacitor current are used in the feedback loop. Using both signals provides higher DC rejection than using capacitor current alone. The proposed active damping scheme results in a faster transient response and higher damping ratio than can be obtained using inverter-side current alone. The feedback gains can be calculated to achieve a specified damping level. A method of determining the gains of the Proportional and Resonant current controller based on frequency response characteristics is presented. For a specified set of gain and phase margins, the controller gains can be calculated explicitly. Furthermore, a modification is proposed to prevent windup in the resonator. A numerically compensated Half-Cycle Discrete Fourier Transform (HCDFT) method is developed to calculate the negative sequence component of the load current. The numerical compensation allows the HCDFT to accurately estimate the fundamental component of the load current under off-nominal frequency conditions. The proposed HCDFT method is shown to have a quick settling time that is comparable to that obtained with conventional sequence compensation techniques as well as immunity to harmonics in the input signal. The effect of unbalance compensation on the PV power output depending on the irradiance and the operational region on the power-voltage curve is examined. Analysis of the DC link voltage ripple shows the region of operation on the P-V curve affects the amplitude of the DC link voltage ripple during negative sequence compensation. The proposed control scheme is validated by simulation in the Matlab/Simulink® environment. The proposed control scheme is tested in the presence of excessive current imbalance, unbalanced feeder impedances, and non-linear loads. The results have shown that the proposed control scheme can improve power quality in a hybrid PV-diesel microgrid by reducing both voltage and current imbalance while simultaneously converting real power from a PV array

    The biology behind the human intervertebral disc and its endplates

    Get PDF
    The intervertebral discs (IVDs) are roughly cylindrical, fibrocartilaginous, articulating structures connecting the vertebral bodies, and allowing movement in the otherwise rigid anterior portion of the vertebral column. They also transfer loads and dissipate energy. Macroscopically the intervertebral disc can be divided into an outer annulus fibrosus surrounding a centrally located nucleus pulposus. The endplates surround the IVD from both the cranial and caudal ends, and separate them from the vertebral bodies and prevent the highly hydrated nucleus pulposus from bulging into the adjacent vertebrae. The IVD develop from the mesodermal notochord and receive nutrients mostly through the cartilaginous endplates. Physiologically they are innervated only in the outer annulus fibrosus by sensory and sympathetic perivascular nerve fibres, branches from the sinuvertebral nerve, the ventral rami of spinal nerves or from the grey rami communicantes. The IVD undergo changes with ageing and degeneration, the latter having two types i.e. “endplate-driven” involving endplate defects and inward collapse of the annulus fibrosus and “annulus-driven” involving a radial fissure and/or an IVD prolapse. This review summarises and updates the current state of knowledge on the embryology, structure, and biomechanics of the IVD and its endplates. To further translate this into a more clinical context this review also demonstrates the impact of ageing and degeneration on the above properties of both the IVD and its endplates.

    Jugular phlebectasia presenting as globus pharyngeus

    Get PDF
    Even though much has been written on the aetiology of globus pharyngeus, itstill remains elusive and multifactorial. We present a case of a 54-year-old womanwho was referred by an orthopedist to the radiology department with a 6-dayhistory of an intense feeling of “pressure” and “tightness” in the jugular notch.After performing a contrast-enhanced computed tomography scan, a phlebectasiaof the right anterior jugular vein was discovered. When trying to determinethe cause of the globus sensation one has to consider the possible existence ofa phlebectasia of one of the jugular veins

    A Pixel Vertex Tracker for the TESLA Detector

    Get PDF
    In order to fully exploit the physics potential of a e+e- linear collider, such as TESLA, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid Silicon pixel sensors are an attractive sensor technology option due to their read-out speed and radiation hardness, favoured in the high rate TESLA environment, but have been so far limited by the achievable single point space resolution. A novel layout of pixel detectors with interleaved cells to improve their spatial resolution is introduced and the results of the characterisation of a first set of test structures are discussed. In this note, a conceptual design of the TESLA Vertex Tracker, based on hybrid pixel sensors is presentedComment: 20 pages, 11 figure

    A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations

    Get PDF
    An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants

    Characterisation of Hybrid Pixel Detectors with capacitive charge division

    Get PDF
    In order to fully exploit the physics potential of the future high energy e+ e- linear collider, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid pixel sensors are an attractive technology due to their fast read-out capabilities and radiation hardness. A novel pixel detector layout with interleaved cells between the readout nodes has been developed to improve the single point resolution. The results of the characterisation of the first processed prototypes are reported.Comment: 5 pages, 2 figures, presented at LCWS2000, Linear Collider Workshop, October 24-28 2000, Fermi National Accelerator Laboratory, Batavia, Illinois, U.S.A. Proceedings to be published by the American Institute of Physic

    Median nerve thenar motor branch anatomical variations

    Get PDF
    Aim. The aim of this study was to determine the prevalence of the different types of the median nerve thenar motor branch and to compare them with literature data.Materials and Methods. This study has been conducted using median nerves dissected from cadavers stored in a 10% solution of formaldehyde at the Department of Anatomy, Jagiellonian University Medical College (JUMC) and cadavers from the Department of Forensic Medicine (JUMC). The research protocol was approved by the Jagiellonian University Ethics Committee (registry KBET/209/B/2002).Results. The studied group comprised of 8 (26,7%) women and 22 men (age between 23-92 years), yielding a total of 60 thenar motor branches (30 right vs. 30 left). Forty-seven (78,3%) nerves were classified as extraligamentous, 12 (20%) were subligamentous and 1 (1,7%) was transligamentous. As for the side of origin of the thenar motor branch in 45 cases (75%) it was the radial side and in 2 cases (3,33%) it was the ulnar side.Conclusions. The obtained results confirm that the extraligamentous type of the thenar motor branch is the most common and that the ulnar origin of the thenar motor branch is the rarest

    Endplate calcification and cervical intervertebral disc degeneration: the role of endplate marrow contact channel occlusion

    Get PDF
    Background: The aim of this study was to determine the fundamental relationships between cervical intervertebral disc (IVD) degeneration, endplate calcification, and the patency of endplate marrow contact channels (MCC). Materials and methods: Sixty cervical IVDs were excised from 30 human cadavers. After sectioning the specimens underwent micro computed tomography (microCT) — from all images the number, calibre, diameter and distribution of endplate openings were measured using ImageJ. Next, the specimens were scored for macroscopic degeneration (Thompson’s classification), and subsequently underwent histological analysis for both IVD and endplate degeneration (Boos’s classification) and calcification. Results: The study group comprised 30 female and 30 male IVDs (mean age ± SD: 51.4 ± 19.5). Specimen’s age, macroscopic and microscopic degeneration correlated negatively with the number of MCCs (r = –0.33–(–0.95); p < 0.0001), apart from the MCCs > 300 μm in diameter (r = 0.66–0.79; p < 0.0001). The negative relationship was strongest for the MCCs 10–50 μm in diameter. Conclusions: There is a strong negative correlation between the number of endplate MCCs, and both macroscopic and microscopic cervical IVD and endplate degeneration. This could further support the thesis that endplate calcification, through the occlusion of MCCs, leads to a fall in nutrient transport to the IVD, and subsequently causes its degeneration
    corecore