    The effect of pure mitral regurgitation on mitral annular geometry and three-dimensional saddle shape

    Get PDF
    ObjectiveChronic ischemic mitral regurgitation is associated with mitral annular dilatation in the septal-lateral dimension and flattening of the annular 3-dimensional saddle shape. To examine whether these perturbations are caused by the ischemic insult, mitral regurgitation, or both, we investigated the effects of pure mitral regurgitation (low pressure volume overload) on annular geometry and shape.MethodsEight radiopaque markers were sutured evenly around the mitral annulus in sheep randomized to control (CTRL, n = 8) or experimental (HOLE, n = 12) groups. In HOLE, a 3.5- to 4.8-mm hole was punched in the posterior leaflet to generate pure mitral regurgitation. Four-dimensional marker coordinates were obtained radiographically 1 and 12 weeks postoperatively. Mitral annular area, annular septal-lateral and commissure–commissure dimensions, and annular height were calculated every 16.7 ms.ResultsMitral regurgitation grade was 0.4 ± 0.4 in CTRL and 3.0 ± 0.8 in HOLE (P < .001) at 12 weeks. End-diastolic left ventricular volume index was greater in HOLE at both 1 and 12 weeks; end-systolic volume index was larger in HOLE at 12 weeks. Mitral annular area increased in HOLE predominantly in the commissure–commissure dimension, with no difference in annular height between HOLE versus CTRL at 1 or 12 weeks, respectively.ConclusionIn contrast with annular septal-lateral dilatation and flattening of the annular saddle shape observed with chronic ischemic mitral regurgitation, pure mitral regurgitation was associated with commissure–commissure dimension annular dilatation and no change in annular shape. Thus, infarction is a more important determinant of septal-lateral dilatation and annular shape than mitral regurgitation, which reinforces the need for disease-specific designs of annuloplasty rings

    Discussion

    No full text

    Geometric data of commercially available tricuspid valve annuloplasty devices

    No full text
    Tricuspid valve annuloplasty is the gold standard surgical treatment for functional tricuspid valve regurgitation. During this procedure, ring-like devices are implanted to reshape the diseased tricuspid valve annulus and to restore function. For the procedure, surgeons can choose from multiple available device options varying in shape and size. In this article, we provide the three-dimensional (3D) scanned geometry (*.stl) and reduced midline (*.vtk) of five different annuloplasty devices of all commercially available sizes. Three-dimensional images were captured using a 3D scanner. After extracting the surface geometry from these images, the images were converted to 3D point clouds and skeletonized to generate a 3D midline of each device. In total, we provide 30 data sets comprising the Edwards Classic, Edwards MC3, Edwards Physio, Medtronic TriAd, and Medtronic Contour 3D of sizes 26–36. This dataset can be used in computational models of tricuspid valve annuloplasty repair to inform accurate repair geometry and boundary conditions. Additionally, others can use these data to compare and inspire new device shapes and sizes
    corecore