27 research outputs found

    Comparison of Post-injection Site Pain Between Technetium Sulfur Colloid and Technetium Tilmanocept in Breast Cancer Patients Undergoing Sentinel Lymph Node Biopsy

    Get PDF
    BACKGROUND: No prior studies have examined injection pain associated with Technetium-99m Tilmanocept (TcTM). METHODS: This was a randomized, double-blinded study comparing postinjection site pain between filtered Technetium Sulfur Colloid (fTcSC) and TcTM in breast cancer lymphoscintigraphy. Pain was evaluated with a visual analogue scale (VAS) (0–100 mm) and the short-form McGill Pain Questionnaire (SF-MPQ). The primary endpoint was mean difference in VAS scores at 1-min postinjection between fTcSC and TcTM. Secondary endpoints included a comparison of SF-MPQ scores between the groups at 5 min postinjection and construction of a linear mixed effects model to evaluate the changes in pain during the 5-min postinjection period. RESULTS: Fifty-two patients underwent injection (27-fTcSC, 25-TcTM). At 1-min postinjection, patients who received fTcSC experienced a mean change in pain of 16.8 mm (standard deviation (SD) 19.5) compared with 0.2 mm (SD 7.3) in TcTM (p = 0.0002). At 5 min postinjection, the mean total score on the SF-MPQ was 2.8 (SD 3.0) for fTcSC versus 2.1 (SD 2.5) for TcTM (p = 0.36). In the mixed effects model, injection agent (p < 0.001), time (p < 0.001) and their interaction (p < 0.001) were associated with change in pain during the 5-min postinjection period. The model found fTcSC resulted in significantly more pain of 15.2 mm (p < 0.001), 11.3 mm (p = 0.001), and 7.5 mm (p = 0.013) at 1, 2, and 3 min postinjection, respectively. CONCLUSIONS: Injection with fTcSC causes significantly more pain during the first 3 min postinjection compared with TcTM in women undergoing lymphoscintigraphy for breast cancer

    Comparison of [(99m)Tc]tilmanocept and filtered [(99m)Tc]sulfur colloid for identification of SLNs in breast cancer patients.

    No full text
    BackgroundThe efficacy of sentinel lymph node (SLN) surgery requires targeted removal of first-draining nodes; however, frequently more nodes are removed than necessary. [(99m)Tc]tilmanocept (TcTM) is a molecular-targeted radiopharmaceutical specifically designed for SLN mapping. We evaluated technical outcomes of SLN biopsy in breast cancer patients mapped with TcTM + vital blue dye (VBD) versus filtered [(99m)Tc]sulfur colloid (fTcSC) + VBD.MethodsThere were 84 versus 115 patients in the TcTM versus fTcSC cohorts, respectively. Main measures were the number of SLNs removed per patient and factors influencing number of nodes removed. We also evaluated whether the radiotracer injected affected the proportion of positive nodes removed in node-positive patients.ResultsFewer nodes were removed among patients mapped with TcTM compared to fTcSC (mean TcTM: 1.85 vs. fTcSC: 3.24, p &lt; 0.001). Logistic regression analysis adjusted for tumor characteristics showed that injection of fTcSC (p &lt; 0.001) independently predicted removal of greater than 3 nodes. A similar proportion of patients was identified as node-positive, whether mapped with TcTM or with fTcSC (TcTM: 24 % vs. fTcSC: 17 %, p = 0.3); however, TcTM detected a greater proportion of positive nodes among node-positive patients compared with fTcSC (0.73 vs. 0.43, p = 0.001).ConclusionsPatients undergoing SLN biopsy with TcTM required fewer SLNs to identify the same rate of node-positive patients compared with fTcSC in breast cancer patients with similar risk of axillary metastatic disease. These data suggest that a molecularly targeted mechanism of SLN identification may reduce the total number of nodes necessary for accurate axillary staging
    corecore