33 research outputs found
IXPE: Instrument User Manual
The purpose of this document is to outline the user manual for the IXPE Instrument
PixDD: a multi-pixel silicon drift detector for high-throughput spectral-timing studies
The Pixelated silicon Drift Detector (PixDD) is a two-dimensional multi-pixel X-ray sensor based on the technology of Silicon Drift Detectors, designed to solve the dead time and pile-up issues of photon-integrating imaging detectors. Read out by a two-dimensional self-triggering Application-Specific Integrated Circuit named RIGEL, to which the sensor is bump-bonded, it operates in the 0:5 — 15 keV energy range and is designed to achieve single-photon sensitivity and good spectroscopic capabilities even at room temperature or with mild cooling (< 150 eV resolution at 6 keV at 0 °C). The paper reports on the design and performance tests of the 128-pixel prototype of the fully integrated system
Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter On-Board the IXPE Mission
The Gas Pixel Detector is a gas detector, sensitive to the polarization of
X-rays, currently flying on-board IXPE - the first observatory dedicated to
X-ray polarimetry. It detects X-rays and their polarization by imaging the
ionization tracks generated by photoelectrons absorbed in the sensitive volume,
and then reconstructing the initial direction of the photoelectrons. The
primary ionization charge is multiplied and ultimately collected on a
finely-pixellated ASIC specifically developed for X-ray polarimetry. The signal
of individual pixels is processed independently and gain variations can be
substantial, of the order of 20%. Such variations need to be equalized to
correctly reconstruct the track shape, and therefore its polarization
direction. The method to do such equalization is presented here and is based on
the comparison between the mean charge of a pixel with respect to the other
pixels for equivalent events. The method is shown to finely equalize the
response of the detectors on board IXPE, allowing a better track reconstruction
and energy resolution, and can in principle be applied to any imaging detector
based on tracks.Comment: Accepted for publication in The Astronomical Journal. 10 pages, 19
figure
In-flight calibration system of imaging x-ray polarimetry explorer
The NASA/ASI Imaging X-ray Polarimetry Explorer, which will be launched in 2021, will be the first instrument to perform spatially resolved X-ray polarimetry on several astronomical sources in the 2-8 keV energy band. These measurements are made possible owing to the use of a gas pixel detector (GPD) at the focus of three X-ray telescopes. The GPD allows simultaneous measurements of the interaction point, energy, arrival time, and polarization angle of detected X-ray photons. The increase in sensitivity, achieved 40 years ago, for imaging and spectroscopy with the Einstein satellite will thus be extended to X-ray polarimetry for the first time. The characteristics of gas multiplication detectors are subject to changes over time. Because the GPD is a novel instrument, it is particularly important to verify its performance and stability during its mission lifetime. For this purpose, the spacecraft hosts a filter and calibration set (FCS), which includes both polarized and unpolarized calibration sources for performing in-flight calibration of the instruments. In this study, we present the design of the flight models of the FCS and the first measurements obtained using silicon drift detectors and CCD cameras, as well as those obtained in thermal vacuum with the flight units of the GPD. We show that the calibration sources successfully assess and verify the functionality of the GPD and validate its scientific results in orbit; this improves our knowledge of the behavior of these detectors in X-ray polarimetry
An Algorithm to Calibrate and Correct the Response to Unpolarized Radiation of the X-Ray Polarimeter Onboard IXPE
The Gas Pixel Detector (GPD) is an X-ray polarimeter to fly onboard IXPE and other missions. To correctly measure the source polarization, the response of IXPE's GPDs to unpolarized radiation has to be calibrated and corrected. In this paper, we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and nonmonochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations
Calibration of the IXPE instrument
IXPE scientific payload comprises of three telescopes, each composed of a mirror and a photoelectric polarimeter based on the Gas Pixel Detector design. The three focal plane detectors, together with the unit which interfaces them to the spacecraft, are named IXPE Instrument and they will be built and calibrated in Italy; in this proceeding, we will present how IXPE Instrument will be calibrated, both on-ground and in-flight. The Instrument Calibration Equipment is being finalized at INAF-IAPS in Rome (Italy) to produce both polarized and unpolarized radiation, with a precise knowledge of direction, position, energy and polarization state of the incident beam. In flight, a set of four calibration sources based on radioactive material and mounted on a filter and calibration wheel will allow for the periodic calibration of all of the three IXPE focal plane detectors independently. A highly polarized source and an unpolarized one will be used to monitor the response to polarization; the remaining two will be used to calibrate the gain through the entire lifetime of the mission
IXPE instrument integration, testing and verification
The Imaging X-ray Polarimetry Explorer (IXPE) is a scientific observatory with the purpose of expand observation space adding polarization property to the X-ray source's currently measured characteristics. The mission selected in the context of NASA Small Explorer (SMEX) is a collaboration between NASA and ASI that will provide to observatory the instrumentation of focal plane. IXPE instrument is composed by three photoelectric polarimeters based on the Gas Pixel Detector (GPD) design, integrated by INFN inside the detector unit (DU) that comprises of the electrical interfaces required to control and communicate with the GPD. The three DUs are interfaced with spacecraft through a detector service unit (DSU) that collect scientific and ancillary data and provides a basically data handling and interfaces to manage the three DUs. AIV has been planned to combine calibration of DUs and Instrument integration and verification activities. Due the tight schedule and the scientific and functional requirements to be verified, in IAPS/INAF have been assembled two equipment's that work in parallel. The flight model of each DU after the environmental tests campaign was calibrated on-ground using the Instrument Calibration Equipment (ICE) and subsequently integrated in the instrument in the AIV-T process on a AIV and Calibration Equipment (ACE), both the facilities managed by Electrical Ground Support Equipment (EGSE) that emulate the spacecraft interfaces of power supply, functional and thermal control and scientific data collection. AIV activities test functionalities and nominal/off-nominal orbits activities of IXPE instrument each time a calibrated DU is connected to DSU flight model completing step by step the full instrument. Here we describe the details of instrumentation and procedures adopted to make possible the full integration and test activities compatibly with calibration of IXPE Instrument
The IXPE Instrument Calibration Equipment
The Imaging X-ray Polarimetry Explorer is a mission dedicated to the
measurement of X-ray polarization from tens of astrophysical sources belonging
to different classes. Expected to be launched at the end of 2021, the payload
comprises three mirrors and three focal plane imaging polarimeters, the latter
being designed and built in Italy. While calibration is always an essential
phase in the development of high-energy space missions, for IXPE it has been
particularly extensive both to calibrate the response to polarization, which is
peculiar to IXPE, and to achieve a statistical uncertainty below the expected
sensitivity. In this paper we present the calibration equipment that was
designed and built at INAF-IAPS in Rome, Italy, for the calibration of the
polarization-sensitive focal plane detectors on-board IXPE. Equipment includes
calibration sources, both polarized and unpolarized, stages to align and move
the beam, test detectors and their mechanical assembly. While all these
equipments were designed to fit the specific needs of the IXPE Instrument
calibration, their versatility could also be used in the future for other
projects