194 research outputs found

    An Amplitude-Based Estimation Method for International Space Station (ISS) Leak Detection and Localization Using Acoustic Sensor Networks

    Get PDF
    The development of a robust and efficient leak detection and localization system within a space station environment presents a unique challenge. A plausible approach includes the implementation of an acoustic sensor network system that can successfully detect the presence of a leak and determine the location of the leak source. Traditional acoustic detection and localization schemes rely on the phase and amplitude information collected by the sensor array system. Furthermore, the acoustic source signals are assumed to be airborne and far-field. Likewise, there are similar applications in sonar. In solids, there are specialized methods for locating events that are used in geology and in acoustic emission testing that involve sensor arrays and depend on a discernable phase front to the received signal. These methods are ineffective if applied to a sensor detection system within the space station environment. In the case of acoustic signal location, there are significant baffling and structural impediments to the sound path and the source could be in the near-field of a sensor in this particular setting

    Principal Component Noise Filtering for NAST-I Radiometric Calibration

    Get PDF
    The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm

    Radiometric Modeling and Calibration of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS)Ground Based Measurement Experiment

    Get PDF
    The ultimate remote sensing benefits of the high resolution Infrared radiance spectrometers will be realized with their geostationary satellite implementation in the form of imaging spectrometers. This will enable dynamic features of the atmosphere s thermodynamic fields and pollutant and greenhouse gas constituents to be observed for revolutionary improvements in weather forecasts and more accurate air quality and climate predictions. As an important step toward realizing this application objective, the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) was successfully developed under the NASA New Millennium Program, 2000-2006. The GIFTS-EDU instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The GIFTS calibration is achieved using internal blackbody calibration references at ambient (260 K) and hot (286 K) temperatures. In this paper, we introduce a refined calibration technique that utilizes Principle Component (PC) analysis to compensate for instrument distortions and artifacts, therefore, enhancing the absolute calibration accuracy. This method is applied to data collected during the GIFTS Ground Based Measurement (GBM) experiment, together with simultaneous observations by the accurately calibrated AERI (Atmospheric Emitted Radiance Interferometer), both simultaneously zenith viewing the sky through the same external scene mirror at ten-minute intervals throughout a cloudless day at Logan Utah on September 13, 2006. The accurately calibrated GIFTS radiances are produced using the first four PC scores in the GIFTS-AERI regression model. Temperature and moisture profiles retrieved from the PC-calibrated GIFTS radiances are verified against radiosonde measurements collected throughout the GIFTS sky measurement period. Using the GIFTS GBM calibration model, we compute the calibrated radiances from data collected during the moon tracking and viewing experiment events. From which, we derive the lunar surface temperature and emissivity associated with the moon viewing measurements

    GIFTS SM EDU Data Processing and Algorithms

    Get PDF
    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration stage. The calibration procedures can be subdivided into three stages. In the pre-calibration stage, a phase correction algorithm is applied to the decimated and filtered complex interferogram. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected blackbody reference spectra. In the radiometric calibration stage, we first compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. During the post-processing stage, we estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. We then implement a correction scheme that compensates for the effect of fore-optics offsets. Finally, for off-axis pixels, the FPA off-axis effects correction is performed. To estimate the performance of the entire FPA, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation

    Mathematical Modeling and Analysis of Drill String Longitudinal Vibration with Lateral Inertia Effect

    Get PDF
    Comparative analysis whether considering the lateral inertia or not, aiming at the longitudinal vibration of the drill string in drilling progress, is proposed. In the light of the actual condition, the mechanical model of the drill string about vibration is established on the basis of the theoretical analysis. Longitudinal vibration equation of the drill string is derived from the Rayleigh-Love model and one-dimensional viscoelastic model. According to the Laplace transform method and the relationships among parameters of the model, the solutions to complex impedance at the bottom of the drill string are obtained, and then the comparison results are analyzed, which is the lateral inertia effect on longitudinal vibration characteristics. The researches show that the smaller the length of the drill string, the greater the cross-sectional area of the drill string, the greater the damping coefficient of bottom hole on the bottom of the drill string, and the more evident the effect on the dynamic stiffness of the drill string with lateral inertia effect. The Poisson ratio of the drill string only has some effects on it taking account of the lateral inertia effect, and the influence is relatively small compared with the former three conditions

    GIFTS SM EDU Level 1B Algorithms

    Get PDF
    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) SensorModule (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the GIFTS SM EDU Level 1B algorithms involved in the calibration. The GIFTS Level 1B calibration procedures can be subdivided into four blocks. In the first block, the measured raw interferograms are first corrected for the detector nonlinearity distortion, followed by the complex filtering and decimation procedure. In the second block, a phase correction algorithm is applied to the filtered and decimated complex interferograms. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected spectrum. The phase correction and spectral smoothing operations are performed on a set of interferogram scans for both ambient and hot blackbody references. To continue with the calibration, we compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. We now can estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. The correction schemes that compensate for the fore-optics offsets and off-axis effects are also implemented. In the third block, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation. Finally, in the fourth block, the single pixel algorithms are applied to the entire FPA

    Optimization of CNOT circuits on topological superconducting processors

    Full text link
    We focus on optimization of the depth/size of CNOT circuits under topological connectivity constraints. We prove that any nn-qubit CNOT circuit can be paralleled to O(n)O(n) depth with n2n^2 ancillas for 22-dimensional grid structure. For the high dimensional grid topological structure in which every quibit connects to 2logn2\log n other qubits, we achieves the asymptotically optimal depth O(logn)O(\log n) with only n2n^2 ancillas. We also consider the synthesis without ancillas. We propose an algorithm uses at most 2n22n^2 CNOT gates for arbitrary connected graph, considerably better than previous works. Experiments also confirmed the performance of our algorithm. We also designed an algorithm for dense graph, which is asymptotically optimal for regular graph. All these results can be applied to stabilizer circuits

    Gliquidone Alleviates Diabetic Nephropathy by Inhibiting Notch/Snail Signaling Pathway

    Get PDF
    Background/Aims: Diabetic nephropathy is a common complication of diabetes. This study explored the renal protective effect and possible mechanism of gliquidone in mice with diabetic nephropathy. Methods: Animal model of diabetic nephropathy was established in KKAy mice. The renal protective effect of gliquidone was studied by evaluating the kidney function through measures of urinary protein, blood urea nitrogen (BUN), serum creatinine (Scr) and serum triglyceride (TG) that were performed using an automatic biochemical analyzer. The levels of oxidative stress indicators, such as nitric oxide (NO), superoxide dismutase (SOD) and malondialdehyde (MDA), were evaluated in renal tissue homogenates using the automatic biochemical analyzer. The inhibitory effect of gliquidone on renal interstitial fibrosis and its association with Notch / Snail1 signaling pathway in diabetic nephropathy was investigated using molecular biological techniques. Results: It was found that low-, medium- and high-dose gliquidone improved the mice’s general health condition, such as mental status, fur condition, eating, and drinking. Gliquidone reduced the body weight and the kidney weight /body weight ratio of mice. Gliquidone improved the kidney function, indicated by reductions in urinary protein, blood urea nitrogen, and serum creatinine and triglyceride. Gliquidone treatment increased levels of nitric oxide and superoxide dismutase, but decreased level of malondialdehyde. The expression of Jagged1/Notch1/hes1/Snail1/α-SMA decreased, while the expression of E-cadherin increased in gliquidone-treated kidneys. High dose gliquidone showed the best effect, one that was similar to that of the positive control drug irbesartan. Conclusion: Taken together, our results suggested that gliquidone can ameliorate the diabetic symptoms of diabetic nephropathy through inhibiting Notch / Snail1 signaling pathway, improving anti -oxidative response and delaying renal interstitial fibrosis. The efficacy of gliquidone is dose-dependent

    Direct reprogramming of induced neural progenitors: a new promising strategy for AD treatment.

    Get PDF
    Alzheimer\u27s disease (AD) is a prominent form of dementia, characterized by aggregation of the amyloid β-peptide (Aβ) plaques and neurofibrillary tangles, loss of synapses and neurons, and degeneration of cognitive functions. Currently, although a variety of medications can relieve some of the symptoms, there is no cure for AD. Recent breakthroughs in the stem cell field provide promising strategies for AD treatment. Stem cells including embryonic stem cells (ESCs), neural stem cells (NSCs), mesenchymal stem cells (MSCs), and induced pluripotent stem cells (iPSCs) are potentials for AD treatment. However, the limitation of cell sources, safety issues, and ethical issues restrict their applications in AD. Recently, the direct reprogramming of induced neural progenitor cells (iNPCs) has shed light on the treatment of AD. In this review, we will discuss the latest progress, challenges, and potential applications of direct reprogramming in AD treatment
    corecore