370 research outputs found

    Linear Lattice and Trajectory Reconstruction and Correction at FAST Linear Accelerator

    Full text link
    The low energy part of the FAST linear accelerator based on 1.3 GHz superconducting RF cavities was successfully commissioned. During commissioning, beam based model dependent methods were used to correct linear lattice and trajectory. Lattice correction algorithm is based on analysis of beam shape from profile monitors and trajectory responses to dipole correctors. Trajectory responses to field gradient variations in quadrupoles and phase variations in superconducting RF cavities were used to correct bunch offsets in quadrupoles and accelerating cavities relative to their magnetic axes. Details of used methods and experimental results are presented.Comment: 3 p

    Replacing paper data collection forms with electronic data entry in the field: findings from a study of community-acquired bloodstream infections in Pemba Zanzibar

    Get PDF
    BackgroundEntering data on case report forms and subsequently digitizing them in electronic media is the traditional way to maintain a record keeping system in field studies. Direct data entry using an electronic device avoids this two-step process. It is gaining in popularity and has replaced the paper-based data entry system in many studies. We report our experiences with paper- and PDA-based data collection during a fever surveillance study in Pemba Island, Zanzibar, Tanzania.MethodsData were collected on a 14-page case report paper form in the first period of the study. The case report paper forms were then replaced with handheld computers (personal digital assistants or PDAs). The PDAs were used for screening and clinical data collection, including a rapid assessment of patient eligibility, real time errors, and inconsistency checking.ResultsA comparison of paper-based data collection with PDA data collection showed that direct data entry via PDA was faster and 25% cheaper. Data was more accurate (7% versus 1% erroneous data) and omission did not occur with electronic data collection. Delayed data turnaround times and late error detections in the paper-based system which made error corrections difficult were avoided using electronic data collection.ConclusionsElectronic data collection offers direct data entry at the initial point of contact. It has numerous advantages and has the potential to replace paper-based data collection in the field. The availability of information and communication technologies for direct data transfer has the potential to improve the conduct of public health research in resource-poor settings

    Evaluation of a Rapid Dipstick (Crystal VC) for the Diagnosis of Cholera in Zanzibar and a Comparison with Previous Studies

    Get PDF
    BackgroundThe gold standard for the diagnosis of cholera is stool culture, but this requires laboratory facilities and takes at least 24 hours. A rapid diagnostic test (RDT) that can be used by minimally trained staff at treatment centers could potentially improve the reporting and management of cholera outbreaks.MethodsWe evaluated the Crystal VC™ RDT under field conditions in Zanzibar in 2009. Patients presenting to treatment centers with watery diarrhea provided a stool sample for rapid diagnostic testing. Results were compared to stool culture performed in a reference laboratory. We assessed the overall performance of the RDT and evaluated whether previous intake of antibiotics, intravenous fluids, location of testing, and skill level of the technician affected the RDT results.ResultsWe included stool samples from 624 patients. Compared to culture, the overall sensitivity of the RDT was 93.1% (95%CI: 88.7 to 96.2%), specificity was 49.2% (95%CI: 44.3 to 54.1%), the positive predictive value was 47.0% (95%CI: 42.1 to 52.0%) and the negative predictive value was 93.6% (95%CI: 89.6 to 96.5%). The overall false positivity rate was 50.8% (213/419); fieldworkers frequently misread very faint test lines as positive.ConclusionThe observed sensitivity of the Crystal VC RDT evaluated was similar compared to earlier versions, while specificity was poorer. The current version of the RDT could potentially be used as a screening tool in the field. Because of the high proportion of false positive results when field workers test stool specimens, positive results will need to be confirmed with stool culture
    corecore