75 research outputs found

    Color-coded summation images for the evaluation of blood flow in endovascular aortic dissection fenestration

    Get PDF
    BACKGROUND: To analyze the benefit of color-coded summation images in the assessment of target lumen perfusion in patients with aortic dissection and malperfusion syndrome before and after fluoroscopy-guided aortic fenestration. METHODS: Between December 2011 and April 2020 25 patients with Stanford type A (n = 13) or type B dissection (n = 12) and malperfusion syndromes were treated with fluoroscopy-guided fenestration of the dissection flap using a re-entry catheter. The procedure was technically successful in 100% of the cases and included additional iliofemoral stent implantation in four patients. Intraprocedural systolic blood pressure measurements for gradient evaluation were performed in 19 cases. Post-processed color-coded DSA images were obtained from all DSA series before and following fenestration. Differences in time to peak (dTTP) values in the compromised aortic lumen and transluminal systolic blood pressure gradients were analyzed retrospectively. Correlation analysis between dTTP and changes in blood pressure gradients was performed. RESULTS: Mean TTP prior to dissection flap fenestration was 6.85 ± 1.35 s. After fenestration, mean TTP decreased significantly to 4.96 ± 0.94 s (p < 0.001). Available systolic blood pressure gradients between the true and the false lumen were reduced by a median of 4.0 mmHg following fenestration (p = 0.031), with significant reductions in Stanford type B dissections (p = 0.013) and minor reductions in type A dissections (p = 0.530). A moderate correlation with no statistical significance was found between dTTP and the difference in systolic blood pressure (r = 0.226; p = 0.351). CONCLUSIONS: Hemodynamic parameters obtained from color-coded DSA confirmed a significant reduction of TTP values in the aortic target lumen in terms of an improved perfusion in the compromised aortic region. Color-coded DSA might thus be a suitable complementary tool in the assessment of complex vascular patterns prevailing in aortic dissections, especially when blood pressure measurements are not conclusive or feasible

    Old name, new face: a systematic analysis of flexor digitorum superficialis muscle with "chiasma antebrachii"

    Get PDF
    he gross anatomy of the forearm flexors, particularly that of the flexor digitorum superficialis (FDS) muscle, has been described and graphically illustrated in several anatomical books and atlases starting in the middle of the century before last. However, in anatomical dissection studies as well as in clinical-anatomical courses training muscle-specific targeted injections due to movement disorders such as dystonia or spasticity, it has become apparent that there is a need for a closer investigation of the complex construction of the FDS muscle. To this end, we studied the structure of the muscle bellies and tendons of FDS on 46 human body donates that have been used either in our dissection or clinical-anatomical training courses. With this, we demonstrate here the topographical configuration of the individual muscle belly for each of digits 2 through 5 and the exact paths of their tendons until their passing through the carpal tunnel. Furthermore, we demonstrate the presence of a chiasm of the FDS tendons for the digits 2 and 3, approximately 3-4 cm proximal of the carpal tunnel. Thus, we introduce herewith the terminology “chiasma antebrachii”. These findings were confirmed in situ by imaging of fixed human body donates via MRI and corroborated by MRI and ultrasound imaging in two volunteers. Taken together, the present findings enable an updated understanding of the complex organization of the heads, bellies, and tendons of FDS that is relevant not only for anatomical teaching but also clinical interventions

    Percutaneous mechanical thrombectomy in acute and subacute lower-extremity ischemia: impact of adjunctive, solely nonthrombolytic endovascular procedures

    Get PDF
    PURPOSEWe aimed to evaluate the role of adjunctive, solely nonthrombolytic endovascular therapy in treatment of acute lower-extremity ischemia by rotational percutaneous mechanical thrombectomy.METHODSA retrospective, single-center evaluation of 165 patients (167 limbs) that underwent rotational percutaneous mechanical thrombectomy between 2009 and 2016 was performed.RESULTSRotational percutaneous mechanical thrombectomy was used as a single therapy in 9.0% (15 limbs), followed by percutaneous aspiration thrombectomy in 6.0% (10 limbs), percutaneous transluminal angioplasty in 19.8% (33 limbs) and stenting in 25.7% (43 limbs). Rotational percutaneous mechanical thrombectomy was followed by any combination of these three interventions in 39.5%. Clinical and technical success was documented in 92.2%, complications in 10.3% (n=17). No significant difference in clinical and technical success was observed using rotational percutaneous mechanical thrombectomy alone or with additional endovascular therapy. On a long-term basis, the re-ischemia-free survival was nearly twice as high as in previous studies that reported more cases treated by rotational percutaneous mechanical thrombectomy alone.CONCLUSIONTo assure a long-lasting primary patency after percutaneous mechanical thrombectomy, concomitant treatment of underlying lesions with adjunctive, nonthrombolytic endovascular methods should be considered

    Percutaneous endobiliary forceps biopsy of biliary strictures for histopathologic examination

    Get PDF
    PURPOSEWe aimed to investigate the feasibility, accuracy and safety of percutaneous endobiliary cholangio-forceps biopsy of biliary strictures in our institution.METHODSA total of 13 percutaneous transhepatic endobiliary biopsies (7 men and 6 women, mean age 66.85±16.76 years) were performed between January 2015 and March 2019 using a transluminal forceps biopsy device. Technical success, rate of complications, number of biopsy specimens, procedure and fluoroscopy time, mean radiation exposure were evaluated; sensitivity and accuracy were calculated.RESULTSTechnical success, i.e., acquisition of at least three (median, 3.00; range, 3–5) macroscopic representative samples, could be achieved in all 13 biopsies. Access was gained via the right liver lobe in 12 of 13 cases (92.3%). All patients presented blood work indicative of cholestasis prior the intervention, with mean bilirubin 4.72±3.72 µmol/L, mean γ-glutamyl transferase 574.16 ± 360.92 IU/L, and median alkaline phosphatase 407 IU/L (165–1366 IU/L). In 12 of 13 cases (92.3%), biopsied material was sufficient for the pathologist to make a histopathologic diagnosis. Analysis revealed cases of malignancy in eight of 13 cases (61.5%), all of which turned out to be cases of cholangiocarcinoma. In four benign cases (30.8%), diagnosis was considered to be confirmed by further imaging or clinical follow-ups, which showed no signs of progressive disease. There was one case (7.7%) of a false-negative result with proof of malignancy in subsequent surgical tissue extraction. A calculation of diagnostic performance yielded a sensitivity rate of 88.9% and an accuracy rate of 92.3%. There was one case of minor and one case of major complication in our study collective, leading to an overall complication rate of 15.4%.CONCLUSIONPercutaneous transhepatic biliary drainage (PTBD)-based forceps biopsy via the transhepatic drainage tract in patients with biliary obstruction of unknown origin is a technically feasible and safe technique with good diagnostic value rates. The procedure should be considered in patients not suitable for endoscopic strategies with indication for establishment of PTBD

    Performance of cone-beam computed tomography (CBCT) in comparison to conventional computed tomography (CT) and magnetic resonance imaging (MRI) for the detection of bone invasion in oral squamous cell cancer (OSCC): a prospective study

    Get PDF
    Background Oral squamous carcinoma (OSCC) is often diagnosed at late stages and bone erosion or invasion of the jawbone is frequently present. Computed tomography (CT) and magnetic resonance imaging (MRI) are known to have high diagnostic sensitivities, specificities, and accuracies in detecting these bone affections in patients suffering from OSCC. To date, the existing data regarding the impact of cone-beam computed tomography (CBCT) have been weak. Therefore, this study aimed to investigate whether CBCT is a suitable tool to detect bone erosion or invasion in patients with OSCC. Methods We investigated in a prospective trial the impact of CBCT in the diagnosis of bone erosion or invasion in patients with OSCC who underwent surgery. Every participant received a CBCT, CT, and MRI scan during staging. Imaging modalities were evaluated by two specialists in oral and maxillofacial surgery (CBCT) and two specialists in radiology (CT and MRI) in a blinded way, to determine whether a bone affection was present or not. Reporting used the following 3-point system: no bony destruction (“0”), cortical bone erosion (“1”), or medullary bone invasion (“2”). Histological examination or a follow-up served to calculate the sensitivities, specificities, and accuracies of the imaging modalities. Results Our results revealed high diagnostic sensitivities (95.6%, 84.4%, and 88.9%), specificities (87.0%, 91.7%, and 91.7%), and accuracies (89.5%, 89.5%, and 90.8%) for CBCT, CT, and MRI. A pairwise comparison found no statistical difference between CBCT, CT, and MRI. Conclusion Our data support the routine use of CBCT in the diagnosis of bone erosion and invasion in patients with OSCC as diagnostic accuracy is equal to CT and MRI, the procedure is cost-effective, and it can be performed during initial contact with the patient

    ESA's Space-based Doppler Wind Lidar Mission Aeolus - First Wind and Aerosol Product Assessment Results

    Get PDF
    The European Space Agency (ESA) wind mission, Aeolus, hosts the first space-based Doppler Wind Lidar (DWL) world-wide. The primary mission objective is to demonstrate the DWL technique for measuring wind profiles from space, intended for assimilation in Numerical Weather Prediction (NWP) models. The wind observations will also be used to advance atmospheric dynamics research and for evaluation of climate models. Mission spinoff products are profiles of cloud and aerosol optical properties. Aeolus was launched on 22 August 2018, and the Atmospheric LAser Doppler INstrument (Aladin) instrument switch-on was completed with first high energy output in wind mode on 4 September 2018. The on-ground data processing facility worked excellent, allowing L2 product output in near-real-time from the start of the mission. First results from the wind profile product (L2B) assessment show that the winds are of very high quality, with random errors in the free Troposphere within (cloud/aerosol backscatter winds: 2.1 m/s) and larger (molecular backscatter winds: 4.3 m/s) than the requirements (2.5 m/s), but still allowing significant positive impact in first preliminary NWP impact experiments. The higher than expected random errors at the time of writing are amongst others due to a lower instrument outand input photon budget than designed. The instrument calibration is working well, and some of the data processing steps are currently being refined to allow to fully correct instrument alignment related drifts and elevated detector dark currents causing biases in the first data product version. The optical properties spin-off product (L2A) is being compared e.g. to NWP model clouds, air quality model forecasts, and collocated ground-based observations. Features including optically thick and thin particle and hydrometeor layers are clearly identified and are being validated

    Imaging in Vasculitis

    No full text
    Purpose of Review: Vasculitides are characterized by mostly autoimmunologically induced inflammatory processes of vascularstructures. They have various clinical and radiologic appearances. Early diagnosis and reliable monitoring are indispensable foradequate therapy to prevent potentially serious complications. Imaging, in addition to laboratory tests and physical examination,constitutes a key component in assessing disease extent and activity. This review presents current standards and some typicalfindings in the context of imaging in vasculitis with particular attention to large vessel vasculitides. Recent Findings: Recently, imaging has gained importance in the management of vasculitis, especially regarding large vesselvasculitides (LVV). Recently, EULAR (European League Against Rheumatism) has launched its recommendations concerningthe diagnosis of LVVs. Imaging is recommended as the preferred complement to clinical examination. Color-coded duplexsonography is considered the first choice imaging test in suspected giant cell arteritis, and magnetic resonance imaging isconsidered the first choice in suspected Takayasu’sarteritis. Summary: Due to diversity of clinical and radiologic presentations, diagnosis and therapy monitoring of vasculitides mayconstitute a challenge. As a result of ongoing technological progress, a variety of non-invasive imaging modalities now playan elemental role in the interdisciplinary management of vasculitic diseases

    Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results.

    No full text
    ObjectivesTo investigate the feasibility, diagnostic image quality and radiation dose of 3rd generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease.MethodsWe retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scan-protocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP).ResultsAll examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv.ConclusionsTaking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases

    Tin-filtered 100kV ultra-low-dose CT of the paranasal sinus: initial clinical results

    No full text
    Objectives To investigate the feasibility, diagnostic image quality and radiation dose of 3rd^{rd} generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. Methods We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scanprotocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). Results All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. Conclusions Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases

    2D-perfusion angiography for intra-procedural endovascular treatment response assessment in chronic mesenteric ischemia: a feasibility study

    No full text
    Background Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI. Methods 49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated. Results Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PDoutflow_{outflow}/PDinflow_{inflow} increased by 65% (p  0.05). Conclusions Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results
    • …
    corecore