1,690 research outputs found

    A Method of Facilitating the Fabrication of Access Openings for Implant-Supported Complete Fixed Dental Prostheses

    Get PDF
    This report describes a method for fabricating access openings for implant-supported complete fixed dental prostheses (ICFP) by using a dental milling machine and silicone putty matrix. The method can help clinicians achieve the accurate and precise fabrication of access openings for ICFPs without excessive grinding

    Analysis of Flexural Strength and Contact Pressure After Simulated Chairside Adjustment of Pressed Lithium Disilicate Glass-Ceramic

    Get PDF
    Statement of problem Research evaluating load-to-failure of pressed lithium disilicate glass-ceramic (LDGC) with a clinically validated test after adjustment and repair procedures is scarce. Purpose The purpose of this in vitro study was to investigate the effect of the simulated chairside adjustment of the intaglio surface of monolithic pressed LDGC and procedures intended to repair damage. Material and methods A total of 423 IPS e.max Press (Ivoclar Vivadent AG) disks (15 mm diameter, 1 mm height) were used in the study. The material was tested by using an equibiaxial loading arrangement (n≥30/group) and a contact pressure test (n≥20/group). Specimens were assigned to 1 of 14 groups. One-half was assigned to the equibiaxial load test and the other half underwent contact pressure testing. Testing was performed in 2 parts, before glazing and after glazing. Before-glazing specimens were devested and entered in the test protocol, while after-glazing specimens were devested and glazed before entering the test protocol. Equibiaxial flexure test specimens were placed on a ring-on-ring apparatus and loaded until failure. Contact pressure specimens were cemented to epoxy resin blocks with a resin cement and loaded with a 50-mm diameter hemisphere until failure. Tests were performed on a universal testing machine with a crosshead speed of 0.5 mm/min. Weibull statistics and likelihood ratio contour plots determined intergroup differences (95% confidence bounds). Results Before glazing, the equibiaxial flexural strength test and the Weibull and likelihood ratio contour plots demonstrated a significantly higher failure strength for 1EC (188 MPa) than that of the damaged and/or repaired groups. Glazing following diamond-adjustment (1EGG) was the most beneficial post-damage procedure (176 MPa). Regarding the contact pressure test, the Weibull and likelihood ratio contour plots revealed no significant difference between the 1PC (98 MPa) and 1PGG (98 MPa) groups. Diamond-adjustment, without glazing (1EG and 1PG), resulted in the next-to-lowest equibiaxial flexure strength and the lowest contact pressure. After glazing, the strength of all the groups, when subjected to glazing following devesting, increased in comparison with corresponding groups in the before-glazing part of the study. Conclusions A glazing treatment improved the mechanical properties of diamond-adjusted IPS e.max Press disks when evaluated by equibiaxial flexure and contact pressure tests. Clinical Implications When adjustments are made on the intaglio surface of a pressed lithium disilicate glass-ceramic, a subsequent glazing treatment is recommended to improve strength

    Comparison of Accuracy and Reproducibility of Casts Made by Digital and Conventional Methods

    Get PDF
    Statement of problem Little peer-reviewed information is available regarding the accuracy and reproducibility of digitally fabricated casts compared to conventional nondigital methods. Purpose The purpose of this in vitro study was to compare the accuracy and reproducibility of a digital impression and cast fabrication with a conventional impression and cast fabrication. Material and methods Conventional impressions were made via a 1-step single viscosity technique with vinyl siloxanether material of a typodont master model, and conventional casts were cast from dental stone. Digital impressions were obtained with a digital scanner, and digital stereolithographic models were printed. The typodont and fabricated casts were digitized with a structured light scanner and saved in surface tessellation language (STL) format. All STL records were superimposed via a best-fit method. The digital impression and cast fabrication method was compared with the conventional impression and cast fabrication method for discrepancy, accuracy, and reproducibility. The Levene test was used to determine equality of variances, and a 1-way ANOVA was conducted to assess the overall statistical significance of differences among the groups (n=5, α=.05). Results No significant statistical difference was found between the digital cast and conventional casts in the internal area or finish line area (P\u3e.05). In addition, there was no statistically significant difference between these 2 techniques for a fixed dental prosthesis or single crown (P\u3e.05). However, statistically significant differences were observed for overall areas of the casts in terms of accuracy (PP Conclusions No statistically significant difference was found between the digital cast and conventional cast groups in the internal and finish line areas. However, in terms of the reproducibility and accuracy of the entire cast area, the conventional cast was significantly better than the digital cast

    A Method of Locating the Abutment Screw Access Channel with Cone-Beam Computed Tomography and a 3D-Printed Drilling Guide

    Get PDF
    In managing loose abutment screws, locating precisely the position of the screw access channel is difficult. This technique describes the use of cone-beam computed tomography (CBCT) and surgical guide planning software to locate the screw access channel with the intention of retrieving a loosened cement-retained implant-supported prosthesis. The method minimizes damage to the abutment crown assembly

    Edge Chipping Resistance and Flexural Strength of Polymer Infiltrated Ceramic Network and Resin Nanoceramic Restorative Materials

    Get PDF
    Statement of problem Two novel restorative materials, a polymer infiltrated ceramic network (PICN) and a resin nanoceramic (RNC), for computer-assisted design and computer-assisted manufacturing (CAD-CAM) applications have recently become commercially available. Little independent evidence regarding their mechanical properties exists to facilitate material selection. Purpose The purpose of this in vitro study was to measure the edge chipping resistance and flexural strength of the PICN and RNC materials and compare them with 2 commonly used feldspathic ceramic (FC) and leucite reinforced glass-ceramic (LRGC) CAD-CAM materials that share the same clinical indications. Material and methods PICN, RNC, FC, and LRGC material specimens were obtained by sectioning commercially available CAD-CAM blocks. Edge chipping test specimens (n=20/material) were adhesively attached to a resin substrate before testing. Edge chips were produced using a 120-degree, sharp, conical diamond indenter mounted on a universal testing machine and positioned 0.1 to 0.7 mm horizontally from the specimen’s edge. The chipping force was plotted against distance to the edge, and the data were fitted to linear and quadratic equations. One-way ANOVA determined intergroup differences (α=.05) in edge chipping toughness. Beam specimens (n=22/material) were tested for determining flexural strength using a 3-point bend test. Weibull statistics determined intergroup differences (α=.05). Flexural modulus and work of fracture were also calculated, and 1-way ANOVA determined intergroup differences (α=.05) Results Significant (PLRGC=FC\u3ePICN; flexural strength: RNC=LRGC\u3ePICN\u3eFC; flexural modulus: RNCLRGC=PICN\u3eFC. Conclusions The RNC material demonstrated superior performance for the mechanical properties tested compared with the other 3 materials

    Evaluation of Die Trim Morphology Made by CAD-CAM Technology

    Get PDF
    Statement of problem The die contour can affect the emergence profile of prosthetic restorations. However, little information is available regarding the congruency between a stereolithographic (SLA) die and its corresponding natural tooth. Purpose The purpose of this vitro study was to evaluate the shapes of SLA die in comparison with the subgingival contour of a prepared tooth to be restored with a ceramic crown. Material and methods Twenty extracted human teeth, 10 incisors, and 10 molars, were disinfected and mounted in a typodont model. The teeth were prepared for a ceramic restoration. Definitive impressions were made using an intraoral scanner from which 20 SLA casts with removable dies were fabricated. The removable dies and corresponding human teeth were digitized using a 3-dimensional desktop scanner and evaluated with computer-aided design software. The subgingival morphology with regard to angle, length, and volume at the buccolingual and mesiodistal surfaces and at zones A, B, C, and D were compared. Data were first analyzed with repeated measures analysis of variance (ANOVA), using locations (buccolingual and mesiodistal), zones (A, B, C, and D), and model type (SLA and Natural) as within-subject factors and tooth type (molar and incisor) as the between-subject factor. Post hoc analyses were performed to investigate the difference between natural teeth and corresponding SLA models, depending upon the interaction effect from the repeated measures ANOVA (α=.05). Results For angle analysis, the incisor group demonstrated a significant difference between the natural tooth and SLA die on the buccolingual surfaces (PPPPPP Conclusions For the comparison of angles, SLA dies did not replicate the subgingival contour of natural teeth on the buccolingual surfaces of the incisal groups. For the comparison of length and volume, SLA dies were more concave and did not replicate the subgingival contour of natural teeth in the incisal and molar groups

    Comparison of The Kois Dento-Facial Analyzer System with an Earbow for Mounting a Maxillary Cast

    Get PDF
    Statement of problem: The Kois Dento-Facial Analyzer System (KDFA) is used by clinicians to mount maxillary casts and evaluate and treat patients. Limited information is available for understanding whether the KDFA should be considered as an alternative to an earbow. Purpose: The purpose of this study was to evaluate maxillary casts mounted using the KDFA with casts mounted using Panadent\u27s Pana-Mount Facebow (PMF). Both articulation methods were compared against a lateral cephalometric radiograph. Material and methods: Fifteen dried human skulls were used. Lateral cephalometric radiographs and 2 maxillary impressions were made of each skull. One cast from each skull was mounted on an articulator by means of the KDFA and the other by using the PMF. A standardized photograph of each articulation was made, and the distance from the articular center to the incisal edge position and the occlusal plane angle were measured. The distance from condylar center to the incisal edge and the occlusal plane angle were measured from cephalometric radiographs. Finally, the 3-dimensional position of each articulation was determined with a Panadent CPI-III. A randomized complete block design analysis of variance (RCBD) and post hoc tests (Tukey-Kramer HSD) (α=.05) were used to evaluate the occlusal plane angle and axis-central incisor distance. A paired 2-sample t test for means (α=.05) was used to compare the X, Y, and Z distance at the right and left condyle. Results: The KDFA and PMF mounted the maxillary cast in a position that was not statistically different from the skull when comparing the occlusal plane angle (P=.165). Both the KDFA and the PMF located the maxillary central incisor edge position in a significantly different position compared with the skull (P=.001) but were not significantly different from each other. The 3-dimensional location of the maxillary casts varied at the condyles by approximately 9 to 10.3 mm. Conclusion: The KDFA mounted the maxillary cast in a position that was not statistically different from the PMF when comparing the incisal edge position and the occlusal plane angle. Both the KDFA and the PMF located the maxillary incisal edge position in a significantly different position compared with the anatomic position on dried human skulls

    Effect of Toothbrushing On Shade and Surface Roughness of Extrinsically Stained Pressable Ceramics

    Get PDF
    Statement of problem The effect of toothbrushing on extrinsically stained pressable ceramic materials is unknown. Purpose The purpose of this in vitro study was to investigate the effects of toothbrushing on the shade and surface roughness of extrinsically stained, pressable ceramics. Material and Methods Two materials, leucite-based (IPS Empress Esthetic [EE]; Ivoclar Vivadent AG) and lithium disilicate-based ceramic (IPS e.max Press [EP]; Ivoclar Vivadent AG), were studied. For each material, 24 disk-shaped specimens, 10 mm (diameter)×3 mm (height) were fabricated. Three different methods (n=8) of applying extrinsic stains were performed on each material: glazed only (G, control group); stained then glazed (SG); and stained and glazed together (T). The specimens were brushed with a multistation brushing machine under a load of 1.96 N at a rate of 90 strokes per minute with a soft and straight toothbrush (Oral-B #35) and a 1:1 toothpaste and distilled water slurry. Shade and roughness were measured at baseline and at 72, 144, 216, and 288 hours, which is equivalent to 3, 6, 9, and 12 years of simulated toothbrushing for 2 minutes twice a day. A repeated measures ANOVA with staining technique as a fixed factor was used to evaluate shade and roughness (α=.05). Results For EE groups, no significant change was found after 12 years of simulated toothbrushing regarding shade and surface roughness, irrespective of staining techniques (P\u3e.05). However, EP groups demonstrated a significant shade change and an increase in surface roughness after 12 years of simulated toothbrushing. Shade change was found to depend on the method of applying stain. For the EP-SG technique, a significant shade change was observed only at the 9- to 12-year interval (P=.047). However, the EP-T technique demonstrated a significant difference in shade between baseline and 3 years (P=.005) and in the 6- to 9-year interval (P=.005). Surface roughness was only significantly affected at baseline and 3 years for the EP-T group (P=.005). Conclusions For the shade and surface roughness of the EE groups, no statistically significant difference was found after 12 years of toothbrushing, irrespective of the staining technique. The shade and surface roughness of the EP groups were significantly statistically affected by toothbrushing time; only shade changes were found to depend on technique

    Die Spacer Thickness Reproduction for Central Incisor Crown Fabrication with Combined Computer-aided Design and 3D Printing Technology: An in vitro Study

    Get PDF
    Statement of problem The inability to control die spacer thickness has been reported. However, little information is available on the congruency between the computer-aided design parameters for die spacer thickness and the actual printout. Purpose The purpose of this study was to evaluate the accuracy and precision of the die spacer thickness achieved by combining computer-aided design and 3-dimensional printing technology. Material and Methods An ivorine maxillary central incisor was prepared for a ceramic crown. The prepared tooth was duplicated by using polyvinyl siloxane duplicating silicone, and 80 die-stone models were produced from Type IV dental stone. The dies were randomly divided into 5 groups with assigned die spacer thicknesses of 25 μm, 45 μm, 65 μm, 85 μm, and 105 μm (n=16). The printed resin copings, obtained from a printer (ProJet DP 3000; 3D Systems), were cemented onto their respective die-stone models with self-adhesive resin cement and stored at room temperature until sectioning into halves in a buccolingual direction. The internal gap was measured at 5 defined locations per side of the sectioned die. Images of the printed resin coping/die-stone model internal gap dimensions were obtained with an inverted bright field metallurgical microscope at ×100 magnification. The acquired digital image was calibrated, and measurements were made using image analysis software. Mixed models (α=.05) were used to evaluate accuracy. A false discovery rate at 5% was used to adjust for multiple testing. Coefficient of variation was used to determine the precision for each group and was evaluated statistically with the Wald test (α=.05). Results The accuracy, expressed in terms of the mean differences between the prescribed die spacer thickness and the measured internal gap (standard deviation), was 50 μm (11) for the 25 μm group simulated die spacer thickness, 30 μm (10) for the 45 μm group, 15 μm (14) for the 65 μm group, 3 μm (23) for the 85 μm group, and -10 μm (32) for the 105 μm group. The precision mean of the measurements, expressed as a coefficient of variation, ranged between 14% and 33% for the 5 groups. Conclusions For the accuracy evaluation, statistically significant differences were found for all the groups, except the group of 85 μm. For the precision assessment, the coefficient of variation was above 10% for all groups, showing the printer’s inability to reproduce the uniform internal gap within the same group

    Resistance to Fracture of Two All-Ceramic Crown Materials Following Endodontic Access

    Get PDF
    Statement of problem There is currently no protocol for managing endodontic access openings for all-ceramic crowns. A direct restorative material is generally used to repair the access opening, rendering a repaired crown as the definitive restoration. This endodontic procedure, however, may weaken the restoration or initiate microcracks that may propagate, resulting in premature failure of the restoration. Purpose The purpose of this in vitro study was to evaluate how an endodontic access opening prepared through an all-ceramic crown altered the structural integrity of the ceramic, and the effect of a repair of this access on the load to failure of an all-ceramic crown. Material and methods Twenty-four alumina (Procera) and 24 zirconia (Procera) crowns were fabricated and cemented (Rely X Luting Plus Cement) onto duplicate epoxy resin dies. Twelve crowns of each were accessed to simulate root canal treatment therapy. Surface defects of all accessed specimens were evaluated with an environmental scanning electron microscope. The specimens were repaired with a porcelain repair system (standard adhesive resin/composite resin protocol) and were loaded to failure in a universal testing machine. Observations made visually and microscopically noted veneer delamination from the core, core fracture, shear within the veneer porcelain, or a combination thereof. A Kruskal-Wallis test was used to determine if a significant difference (α=.05) in load to failure existed between the 4 groups, and a Mann-Whitney test with a Bonferroni correction (P Results All specimens exhibited edge chipping around the access openings. Some displayed larger chips within the veneering porcelain, and 4 zirconia crowns showed radial crack formation. There was a significant difference in load to failure among all groups with the exception of the alumina intact and repaired specimens (P=.695). The alumina crowns generally showed fracture of the coping with the veneering porcelain still bonded to the core, whereas the zirconia copings tended not to fracture but experienced veneering porcelain delamination. Conclusion Endodontic access through all-ceramic crowns resulted in a significant loss of strength in the zirconia specimens but not in the alumina specimens
    • …
    corecore