15 research outputs found

    Pulmonary vein isolation durability and lesion regression in patients with recurrent arrhythmia after pulsed-field ablation.

    Get PDF
    BACKGROUND A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies. OBJECTIVE To present post-market data in patients with recurrent arrhythmias. METHODS Consecutive patients undergoing a redo procedure after an index PFA PVI using a bipolar-biphasic PFA system were included. 3-D electro-anatomical maps (3D-EAM) on redo procedure were compared to the 3D-EAM acquired after ablation during the index procedure. PVI durability was assessed on a per-vein and per-patient level and the sites of reconnections were identified. Furthermore, lesion extent around veins with durable isolation was compared to study lesion regression. RESULTS Of 341 patients treated with a PFA PVI, 29 (8.5%) underwent a left atrial redo ablation due to arrhythmia recurrence. At the end of the index procedure, 110/112 veins (98%, four common ostia) were isolated. On redo procedures performed a median of 6 months after the first ablation, 3D-EAM identified 69/110 (63%) PVs with durable isolation. In 6 (21%) patients, all PVs were durably isolated. Reconnections were more often found on the right-sided veins and on the anterior aspects of the upper veins. Only minor lesion regression was observed between the index and redo procedure (a median of 3 mm (0 - 9.5) on the posterior wall). CONCLUSION In patients with arrhythmia recurrence after PFA PVI using a first-generation PFA device, durable isolation was observed in 63% of the veins and 21% of the patients showed durable isolation of all previously isolated veins

    Pulsed-field vs. cryoballoon vs. radiofrequency ablation: a propensity score matched comparison of one-year outcomes after pulmonary vein isolation in patients with paroxysmal atrial fibrillation.

    Get PDF
    BACKGROUND Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA). METHODS Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients with paroxysmal AF undergoing a first PVI with CBA and RFA were selected using a 1:2:2 propensity score matching. The PFA group followed the standard 32-applications lesion-set protocol, the CBA group a time-to-effect plus 2-min strategy, and the RFA group the CLOSE protocol. Patients were followed with 7d-Holter ECGs 3, 6, and 12 months after ablation. The primary endpoint was recurrence of atrial tachyarrhythmia (ATa) following a blanking period of 3 months. RESULTS A total of 200 patients were included (PFA n = 40; CBA n = 80; RFA n = 80). Median procedure times were shortest with CBA (75 min) followed by PFA (94 min) and RFA (182 min; p < 0.001). Fluoroscopy dose was lowest with RFA (1.6Gycm2) followed by PFA (5.0Gycm2) and CBA (5.7Gycm2; p < 0.001). After a 1-year follow-up, freedom from ATa recurrence was 85.0% with PFA, 66.2% with CBA and 73.8% with RFA (p = 0.12 PFA vs. CBA; p = 0.27 PFA vs. RFA). CONCLUSION In a propensity score matched analysis of patients with paroxysmal AF, freedom from any ATa 1 year after PVI using PFA was favourable and at least as good as for PVI with CBA or RFA

    Posterior wall ablation by pulsed-field ablation - procedural safety, efficacy and findings on redo procedures.

    Get PDF
    BACKGROUND The left atrial posterior wall is a potential ablation target in patients with recurrent atrial fibrillation despite durable pulmonary vein isolation or in patients with roof-dependent atrial tachycardia (AT). Pulsed-field ablation (PFA) offers efficient and safe posterior wall ablation (PWA), but available data is scarce. METHODS Consecutive patients undergoing PWA using PFA were included. PWA was performed using a pentaspline PFA catheter and verified by 3D-electroanatomic mapping. Follow-up was performed using 7-day Holter-ECGs 3, 6, and 12 months after ablation. Recurrence of any atrial arrhythmia lasting more than 30 seconds was defined as failure. Lesion durability was assessed during redo procedures. RESULTS PWA was performed in 215 patients (70% males, median age 70 [IQR 61-75] years, 67% redo procedures) and was successful in all patients (100%) by applying a median of 36 (IQR 32-44) PFA lesions. Severe adverse events were cardiac tamponade and vascular access complication in one patient each (0.9%). Median follow-up was 7.3 (IQR 5.0-11.8) months. One-year arrhythmia-free outcome in Kaplan-Meier analysis was 53%. A redo procedure was performed in 26 patients (12%) after a median of 6.9 (IQR 2.4-11) months and showed durable PWA in 22 patients (85%) with only minor lesion regression. Among 4 patients with posterior wall reconnection, 3 (75%) presented with roof-dependent AT. CONCLUSION PWA with this pentaspline PFA catheter can be safely and efficiently performed with a high durability observed during redo procedures. The added value of durable PWA for the treatment of atrial fibrillation remains to be evaluated

    Incidental Arrhythmias During Atrial Fibrillation Screening With Repeat 7-Day Holter ECGs in a Hospital-Based Patient Population.

    Get PDF
    BACKGROUND Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study. METHODS AND RESULTS In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs. We analyzed all Holter ECGs for the presence of the following incidental arrhythmias: (1) sinus node dysfunction, defined as sinus pause of ≥3 seconds' duration; (2) second-degree (including Wenckebach) or higher-degree atrioventricular block (AVB); (3) sustained supraventricular tachycardia of ≥30 seconds' duration; and (4) sustained ventricular tachycardia of ≥30 seconds' duration. We furthermore report treatment decisions because of incidental arrhythmias. A total of 2077 Holter ECGs were performed in 794 patients (mean age, 74.7 years; 49% women), resulting in a mean cumulative duration of analyzable ECG signal of 414±136 hours/patient. We found incidental arrhythmias in 94 patients (11.8%). Among these were sinus node dysfunction in 14 patients (1.8%), AVB in 41 (5.2%), supraventricular tachycardia in 42 (5.3%), and ventricular tachycardia in 2 (0.3%). Second-degree AVB was found in 23 patients (2.9%), 2:1 AVB in 10 (1.3%), and complete AVB in 8 (1%). Subsequently, 8 patients underwent pacemaker implantation, 1 for sinus node dysfunction (post-AF conversion pause of 9 seconds) and 7 for advanced AVB. One patient had an implantable cardioverter-defibrillator implanted for syncopal ventricular tachycardia. CONCLUSIONS Incidental arrhythmias were frequently detected during screening for AF in the STAR-FIB study and resulted in device therapy in 1.1% of our cohort patients

    Impact of atrial fibrillation phenotype and left atrial volume on outcome after pulmonary vein isolation.

    Get PDF
    AIMS Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation

    Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath.

    Get PDF
    AIMS Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP. METHODS AND RESULTS We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8-16 min). CONCLUSION An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost

    Comprehensive biomarker profiling in patients with obstructive sleep apnea

    No full text
    The pathophysiological links between obstructive sleep apnea syndrome (OSAS) and cardiovascular mortality are incompletely understood. We aimed to contribute to a better characterization by using comprehensive biomarker profiling quantifying hemodynamic cardiac stress, cardiomyocyte injury, inflammation, endothelial function, matrix turnover and metabolism.In 65 patients with moderate or severe OSAS [apnea-hypopnea index (AHI) 39±20/h] and 33 patients with no or mild OSAS (AHI 8+4/h), B-type natriuretic peptide (BNP), N-terminal-pro-BNP (NT-proBNP), high-sensitivity cardiac troponin I (hs-cTnI), interleukin-6 (IL-6), vascular endothelial growth factor (VEGF), matrix metalloproteinase-9 (MMP-9), and insulin were measured before and after sleep. In a subgroup measurements were repeated in a second night with continuous positive airway pressure (CPAP).Patients with moderate/severe OSAS had higher insulin before sleep [median (interquartile range), 36.4 (21.9-52.1) vs. 20.8 (10.6-32.8)mU/mL; p=0.006], higher IL-6 after sleep [1.00 (0.73-1.58) vs. 0.72 (0.48-0.94)pg/mL; p=0.005], and larger relative overnight reduction in BNP [-9 (-35-0) vs. -3 (-21-13)%; p=0.04] than those with mild/no OSAS. Insulin before sleep was the only independent predictor of moderate/severe OSAS. Insulin before and IL-6 after sleep were independent predictors of severe OSAS, and when combined provided high diagnostic accuracy for severe OSAS (area under the receiver operator characteristic curve 0.80; 95%-confidence interval 0.69-0.91). In contrast, there were no significant differences in NT-proBNP, hs-cTnI, VEGF, and MMP-9 between moderate/severe and mild/no OSAS. Short-term CPAP had no impact on biomarker concentrations before and after sleep.Significant OSAS is characterized by a distinct biomarker profile including high insulin before and high IL-6 after sleep

    Conduction System Pacing Today and Tomorrow

    Get PDF
    Conduction system pacing (CSP) encompassing His bundle (HBP) and left bundle branch area pacing (LBBAP) is gaining increasing attention in the electrophysiology community. These relatively novel physiological pacing modalities have the potential to outperform conventional pacing approaches with respect to clinical endpoints, although data are currently still limited. While HBP represents the most physiological form of cardiac stimulation, success rates, bundle branch correction, and electrical lead performance over time remain a concern. LBBAP systems may overcome these limitations. In this review article, we provide a comprehensive overview of the current evidence, implantation technique, device programming, and follow-up considerations concerning CSP systems. Moreover, we discuss ongoing technical developments and future perspectives of CSP

    Evolution of tricuspid valve regurgitation after implantation of a leadless pacemaker - a single center experience, systematic review and meta-analysis.

    No full text
    INTRODUCTION Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation. METHODS Patients who received a leadless LLPM (Micra™ TPS, Medtronic, US) between 05/2016 and 05/2021 at our center were included in this observational study if they had at least a pre- and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random-effects meta-analysis. RESULTS We included 69 patients (median age 78 years [interquartile range (IQR) 72-84 years], 26% women). Follow-up duration between baseline and follow-up TTE was 11.4 months (IQR 3.5-20.1 months). At follow-up, overall TR severity was not different compared to baseline (p=0.49). Six patients (9%) had new significant TR during follow-up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta-analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95%-CI 0.97-1.53, p=0.11). CONCLUSION To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM. This article is protected by copyright. All rights reserved
    corecore