192 research outputs found

    Evaluation of forward osmosis as a pretreatment process for multi stage flash seawater desalination

    Full text link
    © 2019 The present study evaluates the feasibility of applying forward osmosis (FO) process for the pretreatment of feed solution to a Multi Stage Flash (MSF) desalination plant. For the first time, real brine reject and real seawater were used as the draw solution and the feed solution, respectively in the FO process. The FO pretreatment is expected to dilute the brine reject and reduce the concentration of divalent ions, which are responsible for scale formation on the surface of heat exchanger in the MSF evaporator unit. The FO experiments were performed at different draw solution temperatures ranging between 25 and 40 °C, different draw and feed solutions flowrates and different membrane orientations. A maximum average membrane flux of 22.3 L/m2·h was reported at a draw solution temperature of 40 °C and 0.8 and 2.0 LPM flow rate of draw and feed solutions, respectively. The experimental results also revealed the process sensitivity to the feed solution temperature. It was found that the average membrane flux in the FO process operating at 0.8 and 2 LPM draw and feed solution flow rates, respectively was 16.9 L/m2·h at 25 °C brine temperature but increased to 22.3 L/m2·h at 40 °C brine temperature. These membrane fluxes resulted in 3% and 8.5% dilution of the draw solution at 25 °C and 40 °C temperatures, respectively. The average membrane flux in the FO mode was equal to that in the PRO mode at low flow rates but it was lower than that in the PRO mode at high flow rates of the feed and draw solutions. The outcomes of the study are very promising with regard to membrane flux and dilution of draw solution

    Spectrophotometric Assay of Noradrenaline in Pharmaceutical Formulation with Quinalizarin in Aqueous Solution

    Get PDF
    A simple, rapid and sensitive spectrophotometric method for the determination of noradrenaline was developed. The method is based on the proton transfer reaction with quinalizarin in aqueous neutral solution to form a violet product showing maximum absorbance at 560 nm with molar absorptivity of 6680 l.mol-1.cm-1. The method follows Beer’s law over the concentration range (5.91×10-6 -5.91×10-5) mol.L-1 The accuracy (average recovery) of the method is 99.72% and the precision (RSD) of the method is less than 1.5%.The method was successfully applied for the determination of noradrenaline in pharmaceutical formulation as injection and the results were in a good agreement with the standard addition procedure

    Psychosocial aspects of closed- and open-loop insulin delivery: closing the loop in adults with Type 1 diabetes in the home setting.

    Get PDF
    AIMS: To explore the psychosocial experiences of closed-loop technology and to compare ratings of closed- and open-loop technology for adults with Type 1 diabetes taking part in a randomized crossover study. METHODS: Adults (aged > 18 years) on insulin pump therapy were recruited to receive a first phase of either real-time continuous glucose monitoring with overnight closed-loop or real-time continuous glucose monitoring alone (open-loop) followed by a second phase of the alternative treatment in random order, at home for 4 weeks, unsupervised. Participants were invited to share their views in semi-structured interviews. The impact of the closed-loop technology, positive and negative aspects of living with the device overnight, along with the hopes and anxieties of the participants, were explored. RESULTS: The participants in the trial were 24 adults with a mean (sd) age of 43 (12) years, of whom 54% were men. The mean (range) interview duration was 26 (12-46) min. Content and thematic analysis showed the following key positive themes: improved blood glucose control (n = 16); reassurance/reduced worry (n = 16); improved overnight control leading to improved daily functioning and diabetes control (n = 16); and improved sleep (n = 8). The key negative themes were: technical difficulties (n = 24); intrusiveness of alarms (n = 13); and size of equipment (n = 7). Of the 24 participant, 20 would recommend the closed-loop technology. CONCLUSIONS: Closed-loop therapy has positive effects when it works in freeing participants from the demands of self-management. The downside was technical difficulties, particularly concerning the pump and 'connectivity', which it is hoped will improve. Future research should continue to explore the acceptability of the closed-loop system as a realistic therapy option, taking account of user concerns as new systems are designed. Failure to do this may reduce the eventual utility of new systems.Diabetes UKThis is the accepted manuscript. The final version is available at http://dx.doi.org/10.1111/dme.12706

    Students’ perception towards behavioral intention of audio and video teaching styles : an acceptance study

    Get PDF
    Recently audio and video material has been used significantly in various online platforms. The audio-video materials enhance the teaching and learning process by facilitating the transformation of the data and providing a richer interactive environment, hence gaining wide intention within the educational realm. However, empirical studies have not examined the acceptance of the audio and video material depending on a conceptual model where acceptance is the key factor. The present study attempts to overcome this gap in the literature review by investigating the effects of media richness, speed and vividness, perceived concentration, perceived ease of use, perceived usefulness on the acceptance of audio-video material. What distinguishes the current study is the fact that content richness is considered as a mediator that affects all other factors in the conceptual model. The data is collected by distributing the online survey to college students. The results provide mostly insight and support for students’ intention to use audio-visual resources in a conceptual model. The technology characteristics of speed and vividness as well as TAM constructs were significant predictors of technology acceptance. However, it is concluded that the external factor of the perceived concentration has no impact on the students’ perception and intention to use audio-visual resources. In the recommendation, some theoretical and practical implications are stated along with the focus on technology designers, change managers, and users

    The effectiveness of online platforms after the pandemic : will face-to-face classes affect students’ perception of their Behavioural Intention (BIU) to use online platforms?

    Get PDF
    The purpose of this study is to investigate students’ intention to continue using online learning platforms during face-to-face traditional classes in a way that is parallel to their usage during online virtual classes (during the pandemic). This investigation of students’ intention is based on a conceptual model that uses newly used external factors in addition to the technology acceptance model (TAM) contrasts; hence, it takes into consideration users’ satisfaction, the external factor of information richness (IR) and the quality of the educational system and information disseminated. The participants were 768 university students who have experienced the teaching environments of both traditional face-to-face classes and online classes during the pandemic. A structural equation modelling (SEM) test was conducted to analyse the independent variables, including the users’ situation awareness (SA), perceived ease of use, perceived usefulness, satisfaction, IR, education system quality and information quality. An online questionnaire was used to explore students’ perceptions of their intention to use online platforms accessibly in a face-to-face learning environment. The results showed that (a) students prefer online platforms that have a higher level of content richness, to be able to implement the three dimensions of users’ situation awareness (perception, comprehension and projection); (b) there were significant effects of TAM constructs on students’ satisfaction and acceptance; (c) students are in favour of using a learning platform that is characterised by a high level of educational system quality and information quality and (d) students with a higher level of satisfaction have a more positive attitude in their willingness to use the online learning system

    Flash glucose monitoring with the FreeStyle Libre 2 compared with self-monitoring of blood glucose in suboptimally controlled type 1 diabetes: the FLASH-UK randomised controlled trial protocol.

    Get PDF
    INTRODUCTION: Optimising glycaemic control in type 1 diabetes (T1D) remains challenging. Flash glucose monitoring with FreeStyle Libre 2 (FSL2) is a novel alternative to the current standard of care self-monitoring of blood glucose (SMBG). No randomised controlled trials to date have explored the potential benefits of FSL2 in T1D. We aim to assess the impact of FSL2 in people with suboptimal glycaemic control T1D in comparison with SMBG. METHODS: This open-label, multicentre, randomised (via stochastic minimisation), parallel design study conducted at eight UK secondary and primary care centres will aim to recruit 180 people age ≥16 years with T1D for >1 year and glycated haemoglobin (HbA1c) 7.5%-11%. Eligible participants will be randomised to 24 weeks of FSL2 (intervention) or SMBG (control) periods, after 2-week of blinded sensor wear. Participants will be assessed virtually or in-person owing to the COVID-19 pandemic. HbA1c will be measured at baseline, 12 and 24 weeks (primary outcome). Participants will be contacted at 4 and 12 weeks for glucose optimisation. Control participants will wear a blinded sensor during the last 2 weeks. Psychosocial outcomes will be measured at baseline and 24 weeks. Secondary outcomes include sensor-based metrics, insulin doses, adverse events and self-report psychosocial measures. Utility, acceptability, expectations and experience of using FSL2 will be explored. Data on health service resource utilisation will be collected. ANALYSIS: Efficacy analyses will follow intention-to-treat principle. Outcomes will be analysed using analysis of covariance, adjusted for the baseline value of the corresponding outcome, minimisation factors and other known prognostic factors. Both within-trial and life-time economic evaluations, informed by modelling from the perspective of the National Health Service setting, will be performed. ETHICS: The study was approved by Greater Manchester West Research Ethics Committee (reference 19/NW/0081). Informed consent will be sought from all participants. TRIAL REGISTRATION NUMBER: NCT03815006. PROTOCOL VERSION: 4.0 dated 29 June 2020.Diabetes U

    Bolusing frequency and amount impacts glucose control during hybrid closed-loop.

    Get PDF
    AIM: To compare bolus insulin delivery patterns during closed-loop home studies in adults with suboptimally [HbA1c 58-86 mmol/mol (7.5%-10%)] and well-controlled [58 mmol/mol (< 7.5%)] Type 1 diabetes. METHODS: Retrospective analysis of daytime and night-time insulin delivery during home use of closed-loop over 4 weeks. Daytime and night-time controller effort, defined as amount of insulin delivered by closed-loop relative to usual basal insulin delivery, and daytime bolus effort, defined as total bolus insulin delivery relative to total daytime insulin delivery were compared between both cohorts. Correlation analysis was performed between individual bolus behaviour (bolus effort and frequency) and daytime controller efforts, and proportion of time spent within and below sensor glucose target range. RESULTS: Individuals with suboptimally controlled Type 1 diabetes had significantly lower bolus effort (P = 0.038) and daily bolus frequency (P < 0.001) compared with those with well-controlled diabetes. Controller effort during both daytime (P = 0.007) and night-time (P = 0.005) were significantly higher for those with suboptimally controlled Type 1 diabetes. Time when glucose was within the target range (3.9-10.0 mmol/L) during daytime correlated positively with bolus effort (r = 0.37, P = 0.016) and bolus frequency (r = 0.33, P = 0.037). Time when glucose was below the target range during daytime was comparable in both groups (P = 0.36), and did not correlate significantly with bolus effort (r = 0.28, P = 0.066) or bolus frequency (r = -0.21, P = 0.19). CONCLUSION: More frequent bolusing and higher proportion of insulin delivered as bolus during hybrid closed-loop use correlated positively with time glucose was in target range. This emphasises the need for user input and educational support to benefit from this novel therapeutic modality.Seventh Framework Programme of the European Union (ICT FP7- 247138). Additional support for the Artificial Pancreas work by JDRF, National Institute for Health Research Cambridge Biomedical Research Centre, Wellcome Strategic Award (100574/Z/12/Z), EC Horizon 2020 (H2020-SC1-731560), NIDDK (DP3DK112176 and 1UC4DK108520-01), Efficacy and Mechanism Evaluation Programme of National Institute for Health Research (14/23/09) and Helmsley Trust (2016PG-T1D045 and #2016PG-T1D046)

    Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes

    Get PDF
    Objectives\textbf{Objectives}: We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. Methods\textbf{Methods}: Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who underwent, in random order, 12 weeks free-living closed-loop (n = 32) and 12 weeks SAP (n = 33) periods. We quantified daily patterns of main meals, snacks, prandial insulin boluses, correction boluses, and fingerstick glucose measurements by analyzing data recorded on the study glucometer and on study insulin pump. Results\textbf{Results}: We analyzed 1942 closed-loop days and 2530 SAP days. The total number of insulin boluses was reduced during closed-loop versus SAP periods by mean 1.0 per day (95% confidence interval 0.6–1.4, P < 0.001) mainly because of a reduced number of correction boluses by mean 0.7 per day (0.4–1.0, P < 0.001). Other behavioral patterns were unchanged. The carbohydrate content of snacks but not the number of snacks was positively correlated with (1) glycemic variability as measured by standard deviation of sensor glucose (closed-loop P < 0.05; SAP P < 0.01), (2) mean sensor glucose (P < 0.05), and (3) postintervention HbA1c (P < 0.05). Behavioral patterns explained 47% of between-subject variance in glucose variability during SAP period and 30%–33% of variance of means sensor glucose and postintervention HbA1c. Conclusion\textbf{Conclusion}: Fewer correction boluses are delivered during closed-loop period. The size of snacks appears to worsen glucose control possibly because of carbohydrate-rich content of snacks. Modifiable behavioral patterns may be important determinants of glucose control.We acknowledge support by the staff at the Addenbrooke's Wellcome Trust Clinical Research Facility. Josephine Hayes (University of Cambridge) provided administrative support. Karen Whitehead (University of Cambridge) provided laboratory support. We acknowledge support by the staff at Profil Institut, Krisztina Schmitz-Grozs provided support as a research physician, Martina Haase supported the study as an insulin pump expert, and Maren Luebkert, Kirstin Kuschma, and Elke Przetak provided administrative, coordinating, and documentation support. Barbara Semlitsch and Markus Schauer (both from Medical University of Graz) supported the study as insulin pump experts. Funding was by Seventh Framework Programme of the European Union (ICT FP7-247138). Additional support for the Artificial Pancreas work was by JDRF, National Institute for Health Research Cambridge Biomedical Research Centre, Wellcome Strategic Award (100574/Z/12/Z), EC Horizon 2020 (H2020-SC1-731560), NIDDK (DP3DK112176 and 1UC4DK108520-01), Efficacy and Mechanism Evaluation Programme of National Institute for Health Research (14/23/09), and Helmsley Trust (Nos. 2016PG-T1D045 and 2016PG-T1D046). Abbott Diabetes Care supplied discounted continuous glucose monitoring devices, sensors, and communication protocol to facilitate real-time connectivity

    Subjects With Early-Onset Type 2 Diabetes Show Defective Activation of the Skeletal Muscle PGC-1α/Mitofusin-2 Regulatory Pathway in Response to Physical Activity

    Get PDF
    Objective: Type 2 diabetes is associated with insulin resistance and skeletal muscle mitochondrial dysfunction. We have found that subjects with early-onset type 2 diabetes show incapacity to increase Vo2max in response to chronic exercise. This suggests a defect in muscle mitochondrial response to exercise. Here, we have explored the nature of the mechanisms involved. Research design and methods: Muscle biopsies were collected from young type 2 diabetic subjects and obese control subjects before and after acute or chronic exercise protocols, and the expression of genes and/or proteins relevant to mitochondrial function was measured. In particular, the regulatory pathway peroxisome proliferator-activated receptor gamma coactivator (PGC)-1alpha/mitofusin-2 (Mfn2) was analyzed. Results: At baseline, subjects with diabetes showed reduced expression (by 26%) of the mitochondrial fusion protein Mfn2 and a 39% reduction of the alpha-subunit of ATP synthase. Porin expression was unchanged, consistent with normal mitochondrial mass. Chronic exercise led to a 2.8-fold increase in Mfn2, as well as increases in porin, and the alpha-subunit of ATP synthase in muscle from control subjects. However, Mfn2 was unchanged after chronic exercise in individuals with diabetes, whereas porin and alpha-subunit of ATP synthase were increased. Acute exercise caused a fourfold increase in PGC-1alpha expression in muscle from control subjects but not in subjects with diabetes. Conclusions: Our results demonstrate alterations in the regulatory pathway that controls PGC-1alpha expression and induction of Mfn2 in muscle from patients with early-onset type 2 diabetes. Patients with early-onset type 2 diabetes display abnormalities in the exercise-dependent pathway that regulates the expression of PGC-1alpha and Mfn2.</p

    Production, Characterization, and Antimicrobial Activity of Mycocin Produced by Debaryomyces hansenii

    Get PDF
    The present study was conducted to estimate the antimicrobial activity and the potential biological control of the killer toxin produced by D. hansenii DSMZ70238 against several pathogenic microorganisms. In this study, the effects of NaCl, pH, and temperature, killer toxin production, and antimicrobial activity were studied. The results showed that the optimum inhibitory effect of killer toxin was at 8% NaCl, and the diameters of clear zones were 20, 22, 22, 21, 14, and 13 mm for Staphylococcus aureus, Escherichia coli, Klebsiella pneumoniae, Streptococcus pyogenes, Candida albicans, and Candida neoformans, respectively. The largest inhibition zones were observed at pH 4.5 with inhibition zone of 16, 18, 17, 18, 11, and 12 mm for the same microorganisms. The results also showed that 25°C is the optimal temperature for toxin killing activity against all targeted microorganisms. In addition, the activity of killer toxin significantly inhibited the growth of fungal mycelia for all target pathogenic fungi and the percentages of inhibition were 47.77, 48.88, 52.22, and 61.11% for Trichophyton rubrum, Alternaria alternata, Trichophyton concentricum, and Curvularia lunata, respectively. The results showed the highest growth rate of D. hansenii DSMZ70238 under condition of 8% NaCl concentration, pH 4.5, and 25°C for 72 h
    corecore