4 research outputs found

    Compressed Lateral and anteroposterior Anatomical Systematic Sequences «CLASS»: compressed MRI sequences with assessed anatomical femoral and tibial ACL's footprints, a feasibility study

    Full text link
    [EN] Purpose This study's main objective is to assess the feasibility of processing the MRI information with identified ACL-footprints into 2D-images similar to a conventional anteroposterior and lateral X-Ray image of the knee. The secondary aim is to conduct specific measurements to assess the reliability and reproducibility. This study is a proof of concept of this technique. Methods Five anonymised MRIs of a right knee were analysed. A orthopaedic knee surgeon performed the footprints identification. An ad-hoc software allowed a volumetric 3D image projection on a 2D anteroposterior and lateral view. The previously defined anatomical femoral and tibial footprints were precisely identified on these views. Several parameters were measured (e.g. coronal and sagittal ratio of tibial footprint, sagittal ratio of femoral footprint, femoral intercondylar notch roof angle, proximal tibial slope and others). The intraclass correlation coefficient (ICCs), including 95% confidence intervals (CIs), has been calculated to assess intraobserver reproducibility and interobserver reliability. Results Five MRI scans of a right knee have been assessed (three females, two males, mean age of 30.8 years old). Five 2D-"CLASS" have been created. The measured parameters showed a "substantial" to "almost perfect" reproducibility and an "almost perfect" reliability. Conclusion This study confirmed the possibility of generating "CLASS" with the localised centroid of the femoral and tibial ACL footprints from a 3D volumetric model. "CLASS" also showed that these footprints were easily identified on standard anteroposterior and lateral X-Ray views of the same patient, thus allowing an individual identification of the anatomical femoral and tibial ACL's footprints.This work was supported by the University of Fribourg in Switzerland. The study was performed in collaboration with the "Instituto de Biomecanica"-the Polytechnic University of Valencia in Spain.Thürig, G.; Panadero-Morales, R.; Giovannelli, L.; Kocher, F.; Peris-Serra, J.; Tannast, M.; Petek, D. (2022). Compressed Lateral and anteroposterior Anatomical Systematic Sequences «CLASS»: compressed MRI sequences with assessed anatomical femoral and tibial ACL's footprints, a feasibility study. Journal of Experimental Orthopaedics. 9(1):1-7. https://doi.org/10.1186/s40634-022-00445-3179

    Safety of total hip arthroplasty for femoral neck fractures using the direct anterior approach: a retrospective observational study in 86 elderly patients

    Full text link
    Die Doktorarbeit wurde von Herrn Grégoire Thürig vorgelegt von der Klinik für Unfallchirurgie waren Prof. Clément M.L. Werner der Leiter und Prof. Hans-Peter Simmen als Klinikdirektor der Referent. Die Dissertation wurde am 08.12.2016 von Med. Dekanat Zürich genehmig

    Influence of Medial Osteotomy Height and Hinge Position in Open Wedge High Tibial Osteotomy: A Simulation Study

    No full text
    (1) Background: In treating medial unicompartmental gonarthrosis, medial open wedge high tibial osteotomy (mOWHTO) reduces pain and is intended to delay a possible indication for joint replacement by relieving the affected compartment. This study aimed to investigate the influence of the osteotomy height with different hinge points in HTO in genu varum on the leg axis. (2) Methods: Fifty-five patients with varus lower leg alignment obtained full-weight bearing long-leg radiographs were analyzed. Different simulations were performed: Osteotomy height was selected at 3 and 4 cm distal to the tibial articular surface, and the hinge points were selected at 0.5 cm, 1 cm, and 1.5 cm medial to the fibular head, respectively. The target of each correction was 55% of the tibial plateau measured from the medial. Then, the width of the opening wedge was measured. Intraobserver and interobserver reliability were calculated. (3) Results: Statistically significant differences in wedge width were seen at an osteotomy height of 3 cm below the tibial plateau when the distance of the hinge from the fibular head was 0.5 cm to 1.5 cm (3 cm and 0.5 cm: 8.9 +/− 3.88 vs. 3 cm and 1.5 cm: 11.6 +/− 4.39 p = 0.012). Statistically significant differences were also found concerning the wedge width between the distances 0.5 to 1.5 cm from the fibular head at the osteotomy height of 4 cm below the tibial plateau. (4 cm and 0.5 cm: 9.0 +/− 3.76 vs. 4 cm and 1.5 cm: 11.4 +/− 4.27 p = 0.026). (4) Conclusion: A change of the lateral hinge position of 1 cm results in a change in wedge width of approximately 2 mm. If hinge positions are chosen differently in preoperative planning and intraoperatively, the result can lead to over- or under-correction

    Influence of the Fluoroscopy Setting towards the Patient When Identifying the MPFL Insertion Point

    No full text
    (1) The malposition of the femoral tunnel in medial patellofemoral ligament (MPFL) reconstruction can lead to length changes in the MPFL graft, and an increase in medial peak pressure in the patellofemoral joint. It is the cause of 36% of all MPFL revisions. According to Schöttle et al., the creation of the drill canal should be performed in a strictly lateral radiograph. In this study, it was hypothesized that positioning the image receptor to the knee during intraoperative fluoroscopy would lead to a relevant mispositioning of the femoral tunnel, despite an always adjusted true-lateral view. (2) A total of 10 distal femurs were created from 10 knee CT scans using a 3D printer. First, true-lateral fluoroscopies were taken from lateral to medial at a 25 cm (LM25) distance from the image receptor, then from medial to lateral at a 5 cm (ML5) distance. Using the method from Schöttle, the femoral origin of the MPFL was determined when the femur was positioned distally, proximally, superiorly, and inferiorly to the image receptor. (3) The comparison of the selected MPFL insertion points according to Schöttle et al. revealed that the initial determination of the point in the ML5 view resulted in a distal and posterior shift of the point by 5.3 mm ± 1.2 mm when the point was checked in the LM25 view. In the opposite case, when the MPFL insertion was initially determined in the LM25 view and then redetermined in the ML5 view, there was a shift of 4.8 mm ± 2.2 mm anteriorly and proximally. The further positioning of the femur (distal, proximal, superior, and inferior) showed no relevant influence. (4) For fluoroscopic identification of the femoral MPFL, according to Schöttle et al., attention should be paid to the position of the fluoroscopy in addition to a true-lateral view
    corecore