    Tear Film Osmolarity in Response to Long-Term Orthokeratology Treatment

    Get PDF
    Purpose: To compare tear film osmolarity (TFO) measurements in non-contact lens (CL) wearers and wearers of hydrogel or overnight orthokeratology (OK) CLs, and to assess possible effects of long-term OK on TFO. Methods: Overall, 108 subjects with moderate myopia participated in 2 experiments, and TFO was measured using the TearLab osmolarity system. In experiment 1, TFO measurements were made in 77 right eyes of 23 non-CL wearers, 26 hydrogel wearers, and 28 OK wearers. Subjects in the last 2 groups had worn their CL for at least 3 years. In experiment 2, 31 individuals (habitual soft CL wearers) were enrolled for prospective long-term follow-up of OK treatment. These subjects were fitted with Paragon-CRT (n=16) or Seefree (n=15) lenses, and TFO readings were taken at baseline and after 1 month and 1 year of lens wear and after 1 month of OK treatment interruption. Results: Values of TFO were within the normal limits in all 3 subject groups, although significantly lower osmolarities (P<0.01) were observed in non-CL wearers (281.7+/-5.9 mOsm/L) compared with hydrogel (291+/-16.5 mOsm/L) or OK lens wearers (301.7+/-10.8 mOsm/L). In experiment 2, TFO differed significantly at baseline between the Paragon-CRT and Seefree groups (P<0.05), and a significant decrease in TFO compared with baseline (P<0.01) was observed in the Paragon-CRT group after 1 month of cessation of lens wear. Conclusion: Higher TFO values were observed in lens wearers (hydrogel or OK) than non-CL wearers. After interruption of OK treatment, TFO returned to similar values to those found in non-CL wearers

    Long-Term Impacts of Orthokeratology Treatment on Sub-Basal Nerve Plexus and Corneal Sensitivity Responses and Their Reversibility

    Get PDF
    Purpose: To examine the effects of one year of overnight orthokeratology (OK) treatment on the sub-basal nerve plexus (SBNP) and corneal sensitivity and to assess the reversibility of these effects one month after treatment interruption. Methods: Thirty-two subjects with low-moderate myopia underwent OK treatment for one year. Fifteen non-contact lens wearers served as controls. At the time points baseline, one year of treatment, and one month after removing the OK lenses, two tests were conducted: corneal sensitivity (Cochet-Bonnet esthesiometer) and SBNP imaging by in vivo confocal microscopy. Results: In participants wearing OK lenses, significant reductions over the year were produced in SBNP nerve density (P=0.001 and P=0.006) and number of nerves (P<0.001 and P=0.001) in the central and mid-peripheral cornea, respectively. Differences over the year were also detected in central objective tortuosity (P=0.002). After lens removal, baseline values of nerve density (P=0.024 and P=0.001) and number of nerves (P=0.021 and P<0.001) for the central and mid-peripheral cornea, respectively, were not recovered. At one month post-treatment, a difference was observed from one-year values in central corneal sensitivity (P=0.045) and mid-peripheral Langerhans cell density (P=0.033), and from baseline in mid-peripheral objective tortuosity (P=0.049). Direct correlation was detected at one year between nerve density and tortuosity both in the central (P<0.01; r=0.69) and mid-peripheral cornea (P<0.01; r=0.76). Conclusions: Long-term OK treatment led to reduced SBNP nerve density and this was directly correlated with corneal tortuosity. After one month of treatment interruption, nerve density was still reduced

    Efficacy and safety of travoprost/timolol vs dorzolamide/timolol in patients with open-angle glaucoma or ocular hypertension

    Get PDF
    Purpose: To compare the intraocular pressure- (IOP-) lowering efficacy of fixed combinations travoprost 0.004%/timolol 0.5% and dorzolamide 2%/timolol 0.5% in patients with ocular hypertension or open-angle glaucoma. Methods: In this prospective, multicenter, double-masked, randomized clinical trial, 319 qualifying patients received either travoprost/timolol once daily in the morning (n = 157) or dorzolamide/timolol twice daily (n = 162). IOP was assessed morning and evening at 2 and 6 weeks. The primary outcome measure was mean diurnal IOP. Results: Baseline mean IOP values were similar between groups. Mean pooled diurnal IOP was significantly lower in the travoprost/timolol group (16.5 mmHg ± 0.23) than in the dorzolamide/timolol group (17.3 mmHg ± 0.23; P = 0.011). Mean IOP was significantly lower in the travoprost/timolol group compared to the dorzolamide/timolol group at the 9 AM time point both at Week 2 (P = 0.006) and Week 6 (P = 0.002). The travoprost/timolol combination produced mean IOP reductions from baseline of 35.3% to 38.5%, while the dorzolamide/timolol combination produced mean IOP reductions from baseline of 32.5% to 34.5%. Conclusions: The fixed combination travoprost 0.004%/timolol 0.5% dosed once daily in the morning demonstrated superior mean diurnal IOP-lowering efficacy compared to dorzolamide 2%/timolol 0.5% dosed twice daily in patients with ocular hypertension or open-angle glaucoma.publishersversionPeer reviewe

    Impact on Visual Acuity in Neovascular Age Related Macular Degeneration (nAMD) in Europe Due to COVID-19 Pandemic Lockdown

    Full text link
    This is a retrospective, multicenter study of consecutive patients with nAMD scheduled for a visit and/or a treatment with an intravitreal injection (IVI) during the 3 months before lockdown in the Ophthalmology Departments of six centers of Europe.The study was conducted on 546 patients, of which 55.13% were females, almost 100% of the patients were White/Caucasian race, and 71.53% of the patients presented a type 1 macular neovascularization (NVM). A total of 62.82% of patients (343 patients) that were on scheduled clinic visits and/or intravitreal injection treatment during the 3 months before the quarantine did not attend either to visit or for treatment during the lockdown. The mean number of injections during the lockdown was significantly reduced. This was followed by a significant reduction in the mean best-corrected visual acuity (BCVA) between the 3 months before the lockdown (mean BCVA of 60.68 ± 19.77 letters) and 6 months after lockdown (mean BCVA of 56.98 ± 22.59 letters). Patients with better BCVA before the lockdown and the ones showing neovascular activity were more likely to attend their scheduled visits and/or IVI treatments. The COVID-19 pandemic and the lockdown have led to a decrease in the number of IVI treatments in patients with nAMD, evidencing a significant vision loss at 6 months

    Impact on Visual Acuity in Neovascular Age Related Macular Degeneration (nAMD) in Europe Due to COVID-19 Pandemic Lockdown

    Get PDF
    This is a retrospective, multicenter study of consecutive patients with nAMD scheduled for a visit and/or a treatment with an intravitreal injection (IVI) during the 3 months before lockdown in the Ophthalmology Departments of six centers of Europe.The study was conducted on 546 patients, of which 55.13% were females, almost 100% of the patients were White/Caucasian race, and 71.53% of the patients presented a type 1 macular neovascularization (NVM). A total of 62.82% of patients (343 patients) that were on scheduled clinic visits and/or intravitreal injection treatment during the 3 months before the quarantine did not attend either to visit or for treatment during the lockdown. The mean number of injections during the lockdown was significantly reduced. This was followed by a significant reduction in the mean best-corrected visual acuity (BCVA) between the 3 months before the lockdown (mean BCVA of 60.68 +/- 19.77 letters) and 6 months after lockdown (mean BCVA of 56.98 +/- 22.59 letters). Patients with better BCVA before the lockdown and the ones showing neovascular activity were more likely to attend their scheduled visits and/or IVI treatments. The COVID-19 pandemic and the lockdown have led to a decrease in the number of IVI treatments in patients with nAMD, evidencing a significant vision loss at 6 months

    Impact of femtosecond laser-assisted in situ keratomileusis on retinal ganglion cell function

    Get PDF
    Purpose: To analyse the effect of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) on the electrical response of retinal ganglion cells using pattern electroretinography (pERG). Methods: This was a longitudinal, prospective, observational pilot study. We included consecutive myopic patients who underwent FS-LASIK to correct up to 6dioptres of myopia and up to 2dioptres of astigmatism. Patients with excessive blinking or tearing and those with Snellen uncorrected visual acuity less than 0.9 dec on postop day 1 were excluded. Diopsys NOVA® (Diopsys Inc., NJ) pERG records, using high- and low-contrast patterns, were obtained 16 h and 1month after FS-LASIK was performed. Magnitude (μV), Magnitude D (μV), Magnitude D/Magnitude ratio and signal-to-noise ratio (dB) were analysed. Wilcoxon test for nonparametric paired data was employed. Results: pERG data from 24 eyes were analysed from 24 patients who underwent FS-LASIK. Mean age was 35.79±9.86 years. Mean preoperative refraction was −2.69±7.6D (spherical) and −0.38±0.40D (cylinder). Mean surgical time was 56.88±7.6s. No statistically significant differences were obtained for any of the studied parameters when comparing 16h with 1month after FS-LASIK, with the exception of Magnitude with low contrast, which increased from 1.21±0.2 to 1.39±0.29µV at 16 h and 1month postoperatively, respectively (p=0.03). Conclusions: FS-LASIK seems to induce a mild and transitory defect in retinal ganglion cell function. Only a mild decrease was detected in the magnitude value for low-contrast stimuli when pERG was performed 16h postoperatively, and it returned to normal 1 month after surgery

    Impact on refractive surgery due to increasing use of personal protection equipment: Insights from EUROCOVCAT group

    Get PDF
    Since the World Health Organization declared COVID-19 to be a pandemic on 11th March 2020, changes to social and sanitary practices have included significant issues in access and management of eye care during the COVID-19 pandemic. Additionally, the fear of loss, coupled with social distancing, lockdown, economic instability, and uncertainty, have led to a significant psychosocial impact that will have to be addressed. In the current COVID-19 pandemic, personal protective equipment such as face masks or face coverings have become a daily necessity. While "mass masking" along with hand hygiene and social distancing became more widespread, new issues began to emerge - particularly in those who wore spectacles as a means of vision correction. As we began to see routine patients again after the first lockdown had been lifted, many patients visited our clinics for refractive surgery consultations with a primary motivating factor of wanting spectacle independence due to the fogging of their spectacles as a result of wearing a mask. In this article, we report on new emerging issues in eye care due to the widespread use of masks and on the new unmet need in the corneal and cataract refractive surgery fields

    Measurement of the Intraocular Pressure Elevation During Laser-Assisted In Situ Keratomileusis Flap Creation Using a Femtosecond Laser Platform

    Get PDF
    Purpose: The purpose of this study was to measure the intraocular pressure (IOP) elevation during laser assisted in situ keratomileusis (LASIK) flap creation using the WaveLight FS200 femtosecond (FS) laser platform. Methods: We conducted an ex vivo experimental study in an animal model. The WaveLight FS200 FS laser platform was used to perform the corneal LASIK flap in freshly enucleated porcine eyes. We measured the changes in IOP from the application of the suction ring (suctioning phase) through the creation of the lamellar corneal flap (cutting phase). The IOP was recorded using a manometric technique with direct cannulation to the anterior chamber. Results: Nine freshly enucleated porcine eyes were included in the study. The mean baseline IOP before the procedure was 20.33 ± 5.9 mm Hg. The mean IOP increase over baseline IOP was 32.33 ± 11.3 mm Hg at the suctioning phase, and 38.22 ± 11.3 mm Hg at the cutting phase. The total surgical time needed to complete the procedure was 29.5 ± 4.4 seconds. Conclusions: The WaveLight FS200 FS laser platform produces a low to moderate increase in IOP during LASIK flap creation. Translational Relevance: The WaveLight FS200 is a safe FS laser platform because it induces a low to moderate IOP increase during LASIK flap creation