32 research outputs found

    Bipolar Hip Arthroplasty Using a Conjoined Tendon-preserving Posterior Approach in Geriatric Patients

    Get PDF
    In bipolar hemiarthroplasty (BHA), it is important to preserve soft tissue to reduce the risk of postoperative dislocation. A variety of surgical approaches for BHA are available, but extra care is needed with muscle- and tendon-preserving approaches in geriatric patients. We investigated the usefulness of BHA using a conjoined tendon-preserving posterior (CPP) approach, in which only the external obturator muscle is dissected, in geri-atric patients. We retrospectively analyzed the cases of 40 femoral neck fracture patients (10 men, 30 women) aged ≥ 80 years who underwent BHA using the CPP approach. The patients’ average age was 85.8 years (80-94 years). We examined the operation time, bleeding, preservation of short external rotator muscles, complica-tions, and stem alignment and subsidence from postoperative radiographs. Although gemellus inferior muscle injury was detected in 4 patients (10%), the hip joint stability was very excellent in all cases. There was no intraoperative fracture or postoperative dislocation. On postoperative radiographs, all femoral stems were in a neutral position. There was no stem subsidence in all 40 patients. BHA using the CPP approach appeared to be useful even in geriatric patients

    An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position

    Get PDF
    Background Inadequate acetabular component orientation is associated with postoperative impingement, dislocation, and accelerated polyethylene wear. Computed tomography (CT)-based navigation systems provide accuracy for total hip arthroplasty (THA) but are not available in all facilities. Accelerometer-based navigation systems are inexpensive, but their accuracy remains undetermined. This study compares the accuracy of cup orientation in THA using CT-based and accelerometer-based navigation systems. Methods This retrospective study included 35 consecutive patients (11 males, 24 females; mean age, 65 years) who underwent primary cementless THA via an anterolateral approach in the supine position. Both CT-based and accelerometer-based navigation systems were used simultaneously. The accuracy of cup orientation was compared between the two systems using postoperative CT. Results The accuracy of cup inclination was 2.7° ± 2.0° in the CT-based group and 3.3° ± 2.4° in the accelerometer-based group. The accuracy of cup anteversion was 2.8° ± 2.6° in the CT-based group and 3.4° ± 2.2° in the accelerometer-based group. No significant difference was observed in cup inclination (p = 0.29) or cup anteversion (p = 0.34) between CT-based and accelerometer-based navigation. Conclusions The accuracy of cup positioning did not differ significantly between CT-based and accelerometer-based navigation systems

    An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position

    Get PDF
    Background Inadequate acetabular component orientation is associated with postoperative impingement, dislocation, and accelerated polyethylene wear. Computed tomography (CT)-based navigation systems provide accuracy for total hip arthroplasty (THA) but are not available in all facilities. Accelerometer-based navigation systems are inexpensive, but their accuracy remains undetermined. This study compares the accuracy of cup orientation in THA using CT-based and accelerometer-based navigation systems. Methods This retrospective study included 35 consecutive patients (11 males, 24 females; mean age, 65 years) who underwent primary cementless THA via an anterolateral approach in the supine position. Both CT-based and accelerometer-based navigation systems were used simultaneously. The accuracy of cup orientation was compared between the two systems using postoperative CT. Results The accuracy of cup inclination was 2.7° ± 2.0° in the CT-based group and 3.3° ± 2.4° in the accelerometer-based group. The accuracy of cup anteversion was 2.8° ± 2.6° in the CT-based group and 3.4° ± 2.2° in the accelerometer-based group. No significant difference was observed in cup inclination (p = 0.29) or cup anteversion (p = 0.34) between CT-based and accelerometer-based navigation. Conclusions The accuracy of cup positioning did not differ significantly between CT-based and accelerometer-based navigation systems

    Factors influencing caregiver burden in chronic pain patients: A retrospective study

    Get PDF
    Chronic pain coexists with disability, anxiety, depression, and sleep disturbances, which are factors of pain chronicity in the fear-avoidance model. Self-efficacy for managing pain plays a protective role against pain chronicity. For chronic pain sufferers, social support from caregivers is important. However, such caregivers face enormous physical and mental burdens. This study aimed to assess how self-efficacy and factors related to the fear-avoidance model affect caregiver burden. Participants were 135 chronic pain patients and their caregivers who visited our outpatient pain special clinic. In clinical assessments, numeric rating scale (NRS), pain catastrophizing scale (PCS), hospital anxiety and depression scale (HADS), Athens insomnia scale (AIS), pain disability assessment scale (PDAS), pain self-efficacy questionnaire (PSEQ) for the patients and Zarit Burden Interview (ZBI) for their caregivers were evaluated. Participants were divided into 2 groups (L group ZBI = 24 points) and compared. Regression analyses were conducted to identify factors correlated with the ZBI scores. Compared to L group, H group showed significantly higher NRS and HADs depression scores, and lower PSEQ scores. In univariate regression analysis, ZBI scores were significantly correlated with NRS, PCS, HADS anxiety, HADS depression, PDAS and PSEQ. Multiple linear regression analysis revealed that ZBI scores were significantly correlated with PSEQ. The caregivers who perceived high caregiver burden had significantly higher patients' pain intensity, depression, and lower self-efficacy than those who perceived low caregiver burden. Caregiver burden correlated with the pain intensity, pain catastrophizing, anxiety, depression, disability, and self-efficacy of chronic pain patients. Among these factors, self-efficacy was the most negatively correlated with caregiver burden. Treatments focused on increasing self-efficacy for managing pain have the potential to reduce caregiver burden

    Short-term outcomes of mirogabalin in patients with peripheral neuropathic pain: a retrospective study

    Get PDF
    Background Mirogabalin, which is approved for the treatment of peripheral neuropathic pain in Japan, is a ligand for the α2δ subunit of voltage-gated calcium channels. Both pregabalin and mirogabalin act as nonselective ligands at the α2δ-1 and α2δ-2 subunits. Mirogabalin has a unique binding profile and long duration of action. Pregabalin has been reported to produce intolerable adverse effects in some patients. This study investigated outcomes associated with mirogabalin administration in patients with peripheral neuropathic pain who ceased treatment with pregabalin. Methods We retrospectively assessed peripheral neuropathic pain using the neuropathic pain screening questionnaire (NeP score) in 187 patients (58 men, 129 women) who were treated with mirogabalin. All patients had switched from pregabalin to mirogabalin due to lack of efficacy or adverse events. Differences in the treatment course (i.e., numeric rating scale (NRS) scores) were compared using one-way analysis of variance with Bonferroni post hoc tests. Results The mean age of the patients was 72.3 years (range, 30–94 years), and the mean duration of disease was 37 months (range, 3–252 months). After treatment with mirogabalin for 1 week, NRS scores significantly decreased compared with baseline and continued to decrease over time. After 8 weeks, NRS scores improved by ≥ 30% from baseline in 113 patients (69.3%). Twenty-four patients (12.8%) stopped mirogabalin treatment due to adverse events. Somnolence (26.7%), dizziness (12.3%), edema (5.9%), and weight gain (0.5%) were noted as adverse events of mirogabalin. Conclusions The results of this investigation indicate that mirogabalin is safe and effective for reducing peripheral neuropathic pain

    Maximal Resection of Intramedullary Lipoma Using Intraoperative Ultrasonography: A Technical Note

    Get PDF
    One of the problems during surgery for intramedullary lipoma is the ambiguous boundary between the lipoma and the spinal cord, resulting in either incomplete resection or damage to the spinal cord. We report a case of intramedullary lipoma resection on a 61-year-old man in which the boundary between the tumor and spinal cord was repeatedly visualized with intraoperative ultrasonography. We focused on the distinctive features of fat as hyperechoic, in contrast to low-echo neural tissue. Subtotal resection of the tumor was achieved without any aggravation of neurological symptoms. Intraoperative ultrasonography may be useful for confirming tumor boundaries during intramedullary lipoma resection

    Chiari Type I Malformation Caused by Craniometaphyseal Dysplasia

    Get PDF
    Craniometaphyseal dysplasia is a rare genetic condition characterized by progressive thickening of bones in the skull and metaphyseal abnormalities in the long bones. This disorder often causes progressively symptomatic cranial nerve compression, but in rare cases foramen magnum stenosis may lead to quadriplegia. Chiari I malformation with craniometaphyseal dysplasia is extremely rare. The authors report on a 25-year-old woman with myelopathy due to Chiari I malformation along with craniometaphyseal dysplasia. There are only four previous case reports of this condition. The authors present here the fifth case report of this rare condition and summarize its characteristics

    Quantification of patellar tendon reflex using portable mechanomyography and electromyography devices

    Get PDF
    Deep tendon reflexes are one of the main components of the clinical nervous system examinations. These assessments are inexpensive and quick. However, evaluation can be subjective and qualitative. This study aimed to objectively evaluate hyperreflexia of the patellar tendon reflex using portable mechanomyography (MMG) and electromyography (EMG) devices. This study included 10 preoperative patients (20 legs) who had a pathology that could cause bilateral patellar tendon hyperreflexia and 12 healthy volunteers (24 legs) with no prior history of neurological disorders. We attached MMG/EMG sensors onto the quadriceps and tapped the patellar tendon with maximal and constant force. Our results showed a significantly high amplitude of the root mean square (RMS) and low frequency of the mean power frequency (MPF) in the rectus femoris, vastus medialis, and vastus lateralis muscles in both EMG and MMG with both maximal and constant force. Especially in the patients with cervical and thoracic myelopathy, the receiver operating characteristic (ROC) curve for diagnosing hyperreflexia of the patellar tendon showed a moderate to very high area under the curve for all EMG-RMS, EMG-MPF, MMG-RMS, and MMG-MPF values. The use of EMG and MMG for objectively quantifying the patellar tendon reflex is simple and desirable for future clinical applications and could help diagnose neurological disorders

    Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment

    Get PDF
    Background and Objectives: Spine surgery using a percutaneous pedicle screw placement (PPSP) is widely implemented for spinal trauma. However, percutaneous systems have been reported to have weak screw-rod connections. In this study, conventional open and percutaneous systems were biomechanically evaluated and compared. Material and Methods: The experiments were performed in two stages: the first stage was a break test, whereas the second stage was a fatigue test. Four systems were used for the experiments. System 1 was intended for conventional open surgery (titanium rod with a 6.0 mm diameter, using a clamp connecting mechanism). System 2 was a percutaneous pedicle screw (PPS) system for trauma (titanium alloy rod with a 6.0 mm diameter, using ball ring connections). System 3 was a PPS system for trauma (cobalt-chromium alloy rod with a 6.0 mm diameter, using sagittal adjusting screw connections). System 4 was a general-purpose PPS system (titanium alloy rod with a 5.5 mm diameter, using a mechanism where the adapter in the head holds down the screw). Results: Stiffness values of 54.8 N/mm, 43.1 N/mm, 90.9 N/mm, and 39.3 N/mm were reported for systems 1, 2, 3, and 4, respectively. The average number of load cycles in the fatigue test was 134,393, 40,980, 1,550,389, and 147,724 for systems 1 to 4, respectively. At the end of the test, the displacements were 0.2 mm, 16.9 mm, 1.2 mm, and 8.6 mm, respectively. System 1, with a locking mechanism, showed the least displacement at the end of the test. Conclusion: A few PPS systems showed better results in terms on stiffness and life than the open system. The experiments showed that mechanical strength varies depending on the spinal implant. The experiments conducted are essential and significant to provide the mechanical strength required for surgical reconstruction

    A Multidisciplinary Approach to the Management of Chronic Pain through a Self-managed Behavioral Exercise Program : A Pilot Study in Japan

    Get PDF
    We conducted this study to determine the short-term treatment outcomes of multidisciplinary approaches to chronic pain management for outpatients in Japan. We evaluated pain reduction and improvement in quality of life (QOL) after treatment. We analyzed 32 patients who had experienced intractable chronic pain for > 3 months. The patients received multidisciplinary therapeutic self-managed exercise instructions and then underwent evaluations 1 and 3 months after the treatment. We used the Pain Disability Short Form-36 (SF-36), Pain Catastrophizing Scale (PCS), and Pain Disability Assessment Scale (PDAS) to evaluate QOL. Although the pain levels were the same before and after the physical exercise program, the patients showed significant improvements in physical function on the SF-36 (48.5 vs. 54.5, 3 months vs. 1 month; p=0.0124), the magnification subscale on the PCS (6.8 vs. 5.9, 1 month vs. before; p=0.0164) and the PDAS (29.2 vs. 23.4, 3 months vs. before; p=0.0055). Chronic pain should be treated with a biopsychosocial approach, but time constraints and costs have limited the implementation of multidisciplinary and behavioral approaches to chronic pain management. Our findings demonstrate that clinical improvements are possible for patients with chronic pain, using multidisciplinary team resources widely available in Japanese clinical practice
    corecore