84 research outputs found

    Evaluation of initial setup errors of two immobilization devices for lung stereotactic body radiation therapy (SBRT)

    Get PDF
    The aim of this study was to investigate the accuracy and efficacy of two commonly used commercial immobilization systems for stereotactic body radiation therapy (SBRT) in lung cancer. This retrospective study assessed the efficacy and setup accuracy of two immobilization systems: the Elekta Body Frame (EBF) and the Civco Body Pro-Lok (CBP) in 80 patients evenly divided for each system. A cone beam CT (CBCT) was used before each treatment fraction for setup correction in both devices. Analyzed shifts were applied for setup correction and CBCT was repeated. If a large shift (>5 mm) occurred in any direction, an additional CBCT was employed for verification after localization. The efficacy of patient setup was analyzed for 105 sessions (48 with the EBF, 57 with the CBP). Result indicates that the CBCT was repeated at the 1st treatment session in 22.5% and 47.5% of the EBF and CBP cases, respectively. The systematic errors {left–right (LR), anterior–posterior (AP), cranio-caudal (CC), and 3D vector shift: (LR2 + AP2 + CC2)1/2 (mm)}, were {0.5 ± 3.7, 2.3 ± 2.5, 0.7 ± 3.5, 7.1 ± 3.1} mm and {0.4 ± 3.6, 0.7 ± 4.0, 0.0 ± 5.5, 9.2 ± 4.2} mm, and the random setup errors were {5.1, 3.0, 3.5, 3.9} mm and {4.6, 4.8, 5.4, 5.3} mm for the EBF and the CBP, respectively. The 3D vector shift was significantly larger for the CBP (P < 0.01). The setup time was slightly longer for the EBF (EBF: 15.1 min, CBP: 13.7 min), but the difference was not statistically significant. It is concluded that adequate accuracy in SBRT can be achieved with either system if image guidance is used. However, patient comfort could dictate the use of CBP system with slightly reduced accuracy

    Convolutional neural network-based automatic liver delineation on contrast-enhanced and non-contrast-enhanced CT images for radiotherapy planning

    Get PDF
    AimThis study evaluated a convolutional neural network (CNN) for automatically delineating the liver on contrast-enhanced or non-contrast-enhanced CT, making comparisons with a commercial automated technique (MIM Maestro®).BackgroundIntensity-modulated radiation therapy requires careful labor-intensive planning involving delineation of the target and organs on CT or MR images to ensure delivery of the effective dose to the target while avoiding organs at risk.Materials and MethodsContrast-enhanced planning CT images from 101 pancreatic cancer cases and accompanying mask images showing manually-delineated liver contours were used to train the CNN to segment the liver. The trained CNN then performed liver segmentation on a further 20 contrast-enhanced and 15 non-contrastenhanced CT image sets, producing three-dimensional mask images of the liver.ResultsFor both contrast-enhanced and non-contrast-enhanced images, the mean Dice similarity coefficients between CNN segmentations and ground-truth manual segmentations were significantly higher than those between ground-truth and MIM Maestro software (p

    Can we safely reduce the radiation dose to the heart while compromising the dose to the lungs in oesophageal cancer patients?

    Get PDF
    PURPOSE: The aim of this study was to evaluate which clinical and treatment-related factors are associated with heart and lung toxicity in oesophageal cancer patients treated with chemoradiation (CRT). The secondary objective was to analyse whether these toxicities are associated with overall survival (OS) MATERIALS AND METHODS: The study population consisted of a retrospective cohort of 216 oesophageal cancer patients treated with curative CRT. Clinical and treatment related factors were analysed for OS and new pulmonary and cardiac events by multivariable regression analyses. The effect of these toxicities on OS was assessed by Kaplan Meyer analyses. RESULTS: Multivariable analysis revealed that pulmonary toxicity was best predicted by the mean lung dose. Cardiac complications were diverse; the most frequently occurring complication was pericardial effusion. Several cardiac dose parameters correlated with this endpoint. Patients developing radiation pneumonitis had significantly worse OS than patients without radiation pneumonitis, while no difference was observed in OS between patients with and without pericardial effusion. OS was best predicted by the V45 of the lung and tumour stage. None of the cardiac dose parameters predicted OS in multivariable analyses. CONCLUSION: Cardiac dose volume parameters predicted the risk of pericardial effusion and pulmonary dose volume parameters predicted the risk of radiation pneumonitis. However, in this patient cohort, pulmonary DVH parameters (V45) were more important for OS than cardiac DVH parameters. These results suggest that reducing the cardiac dose at the expense of the dose to the lungs might not always be a good strategy in oesophageal cancer patients

    Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer

    Get PDF
    Background: The aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD). Materials and methods: All measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I’mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm3) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT. Results: In the phantom study, no systematic setup error was detected in the range that can happen in clinical ( &lt; 5-mm and &lt; 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% &lt; 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment. Conclusions: Our results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients

    Setup accuracy and dose attenuation of a wooden immobilization system for lung stereotactic body radiotherapy

    Get PDF
    Background: We evaluated the setup error and dose absorption of an immobilization system with a shell and wooden baseplate (SW) for lung stereotactic body radiotherapy (SBRT). Materials and methods: Setup errors in 109 patients immobilized with an SW or BodyFix system (BF) were compared. Dose attenuation rates of materials for baseplates were measured with an ion-chamber. Ionization measurements were performed from 90° to 180° gantry angle in 10° increments, with the ball water equivalent phantom placed at the center of the wood and carbon baseplates whose effects on dose distribution were compared using an electron portal imaging device. Results: The ratio for the anterior-posterior, cranial-caudal, and right-left of the cases within 3-mm registered shifts in interfractional setup error were 90.9%, 89.2%, and 97.4% for the SW, and 93.2%, 91.6%, and 98.0% for the BF, respectively. For intrafractional setup error, 98.3%, 97.4%, and 99.1% for the SW and 96.6%, 95.8%, and 98.7% for the BF were within 3-mm registered shifts, respectively. In the center position, the average (minimum/maximum) dose attenuation rates from 90° to 180° for the wooden and carbon baseplates were 0.5 (0.1/2.8)% and 1.0 (–0.1/10.1)% with 6 MV, respectively. The gamma passing rates of 2%/2 mm for the wooden and carbon baseplates were 99.7% and 98.3% (p &lt; 0.01). Conclusions: The immobilization system with an SW is effective for lung SBRT since it is comparable to the BF in setup accuracy. Moreover, the wooden baseplate had lower radiation attenuation rates and affected the dose distribution less than the carbon baseplate.

    Early administration of IL-6RA does not prevent radiation-induced lung injury in mice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Radiation pneumonia and subsequent radiation lung fibrosis are major dose-limiting complications for patients undergoing thoracic radiotherapy. Interleukin-6 (IL-6) is a pleiotropic cytokine and plays important roles in the regulation of immune response and inflammation. The purpose of this study was to investigate whether anti-IL-6 monoclonal receptor antibody (IL-6RA) could ameliorate radiation-induced lung injury in mice.</p> <p>Methods</p> <p>BALB/cAnNCrj mice having received thoracic irradiation of 21 Gy were injected intraperitoneally with IL-6RA (MR16-1) or control rat IgG twice, immediately and seven days after irradiation. Enzyme-linked immunosorbent assay was used to examine the plasma level of IL-6 and serum amyloid A (SAA). Lung injury was assessed by histological staining with haematoxylin and eosin or Azan, measuring lung weight, and hydroxyproline.</p> <p>Results</p> <p>The mice treated with IL-6RA did not survive significantly longer than the rat IgG control. We observed marked up-regulation of IL-6 in mice treated with IL-6RA 150 days after irradiation, whereas IL-6RA temporarily suppressed early radiation-induced increase in the IL-6 release level. Histopathologic assessment showed no differences in lung section or lung weight between mice treated with IL-6RA and control.</p> <p>Conclusions</p> <p>Our findings suggest that early treatment with IL-6RA after irradiation alone does not protect against radiation-induced lung injury.</p