304 research outputs found

    Micromotion-induced peri-prosthetic fluid flow around a cementless femoral stem

    Get PDF
    Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to characterize and quantify micromotion-induced fluid flow around a cementless femoral stem using finite element modeling. With a 2D model of the bone-implant interface and full-factorial design, we first evaluated the relative influence of material properties, and bone-implant micromotion and gap on fluid velocity. Transverse sections around a femoral stem were built from computed tomography images, while boundary conditions were obtained from experimental measurements on the same femur. In a second step, a 3D model was built from the same dataset to estimate the shear stress experienced by cells hosted in the peri-implant tissues. The full-factorial design analysis showed that local micromotion had the most influence on peak fluid velocity at the interface. Remarkable variations in fluid velocity were observed in the macrostructures at the surface of the implant in the 2D transverse sections of the stem. The 3D model predicted peak fluid velocities extending up to 2.2 mm/s in the granulation tissue and to 3.9 mm/s in the trabecular bone. Peak shear stresses on the cells hosted in these tissues ranged from 0.1 Pa to 12.5 Pa. These results offer insight into mechanical stimuli encountered at the bone-implant interface

    Osteoclastogenesis can be mechanically-induced in the peri-implant bone

    Get PDF
    Total joint replacements are highly successful in relieving pain and restoring movement of damaged joints. However, the lifespan of the implants is limited. The implant’s long-term stability depends largely on the preservation of periprosthetic bone. Debris-wear particulates were first identified as the factor inducing periprosthetic bone loss. However, it was later shown that the resorption process starts before the particulates reach the periprosthetic bone. Thus a mechanical factor, interface micromotions, has been suspected to be the initiator of the early bone loss. In this work, we then investigated the response of bone cells to micromotions. Using an ex vivo setup, we applied micromotions on fresh human bone cores and showed that micromotions could indirectly activate osteoclasts after only 1 hour of stimulation. Thus micromotion-related osteoclastic activity could be the initiator of periprosthetic bone loss

    Microstimulations at the bone implant interface upregulate osteoclast activation pathway

    Get PDF
    Peri-implant bone resorption after total joint arthroplasty is a key parameter in aseptic loosening. Implant wear debris and biomechanical aspects have both been demonstrated to be part of the bone resorption process. However, neither of these two parameters has been clearly identified as the primary initiator of peri-implant bone resorption. For the biomechanical parameters, micromotions were measured at the bone implant interface during normal gait cycles. The amplitude of the micromotions was shown to trigger differentiation of bone tissues. So far no data exists directly quantifying the effect of micromotion and compression on human bone. We hypothesize that micromotion and compression at the bone implant interface may induce direct activation of bone resorption around the implant through osteoblasts- osteoclasts cell signaling in human bone. This hypothesis was tested with an ex vivo loading system developed to stimulate trabecular bone cores and mimic the micromotions arising at the bone-implant interface. Gene expression of RANKL, OPG, TGFB2, IFNG and CSF-1 were analyzed after no mechanical stimulation (control), exposure to static compression or exposure to micromotions. We observed an 8-fold upregulation of RANKL after exposure to micromotions, and down regulation of OPG, IFNG and TGFB2. The RANK:OPG ratio was up regulated 24 fold after micromotions. This suggests that the micromotions arising at the bone-implant interface during normal gait cycles induce a bone resorption response after only one hour, which occurs before any wear debris particles enter the system

    Time course of bone screw fixation following a local delivery of zoledronate in a rat femoral model – a micro-finite element analysis

    Get PDF
    A good fixation of osteosynthesis implants is crucial for a successful bone healing but often difficult to achieve in osteoporotic patients. One possible solution to this issue is the local delivery of bisphosphonates in direct proximity to the implants, A critical aspect of this method, that has not yet been well investigated, is the time course of the implant fixation following the drug release. Usual destructive mechanical tests require large numbers of animals to produce meaningful results. Therefore, a micro-finite element (microFE) approach was chosen to analyze implant fixation. In vivo micro computed tomography (microCT) scans were obtained, first weekly and later bi-weekly, after implantation of polymeric screws in the femoral condyles of ovariectomized rats. In one half of the animals, Zoledronate was released from a hydrogel matrix directly in the peri-implant bone stock, the other animals were implanted only with screws as control. The time course of the implant fixation was investigated with linear elastic microFE models that were created based on in vivo microCT scans. The numerical models were validated against experimental pullout-tests measurements in an additional cadaver study. The microFE analysis revealed a significant increase in force at yield of the Zoledronate treated group compared to the control group. The force of the treated group was 28% higher after 17 days of screw implantation, 42% higher after 31 days. The significant difference persisted until the end of the in vivo study at day 58 (p<0.01). The early onset and prolonged duration of the implant anchorage improvement that was found in this study indicates the great potential of Zoledronate-loaded hydrogel for an enhancement of osteosynthesis implant fixation in impaired bone

    Development and experimental validation of a finite element model of total ankle replacement

    Get PDF
    Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2 kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions

    Effects of the posterior cruciate ligament reconstruction on the biomechanics of the knee joint: a finite element analysis

    Get PDF
    Background. Previous experimental studies have been conducted to evaluate the biomechanical effects of posterior cruciate ligament reconstruction; but no consensus has been reached on the preferred method of reconstruction. Methods. The 3D finite element mesh of a knee joint was reconstructed from computed tomography and magnetic resonance images. The ligaments were considered as hyperelastic materials. The tibiofemoral and patellofemoral joints were modeled with large sliding contact elements. The 3D model was used to simulate knee flexion from 0 degrees to 90 degrees in four cases: a knee with a "native" posterior cruciate ligament, a resected posterior cruciate ligament, a reconstructed single graft posterior cruciate ligament, and a reconstructed double graft posterior cruciate ligament. Findings. A resected posterior cruciate ligament induced high compressive forces in the medial tibiofemoral and patellofemoral compartments. The pressures generated in the tibiofemoral and patellofemoral compartments were nearly the same for the two reconstruction techniques (single graft and double graft). The single graft resulted in lower tensile stresses inside the graft than for the double graft. Interpretation. Firstly, a resected posterior cruciate ligament should be replaced to avoid excessive compressive forces, which are a source of cartilage degeneration. Secondly, the two types of posterior cruciate ligament reconstruction techniques partially restored the biomechanics of the knee in flexion, e.g. contact pressures were restored for pure flexion of the knee. The reconstruction techniques therefore partially restore the biomechanics of the knee in flexion. A double graft reconstruction is subjected to the highest tensile stresses. (c) 2005 Elsevier Ltd. All rights reserved
    • …
    corecore