77 research outputs found

    Steady State Entanglement in Cavity QED

    Full text link
    We investigate steady state entanglement in an open quantum system, specifically a single atom in a driven optical cavity with cavity loss and spontaneous emission. The system reaches a steady pure state when driven very weakly. Under these conditions, there is an optimal value for atom-field coupling to maximize entanglement, as larger coupling favors a loss port due to the cavity enhanced spontaneous emission. We address ways to implement measurements of entanglement witnesses and find that normalized cross-correlation functions are indicators of the entanglement in the system. The magnitude of the equal time intensity-field cross correlation between the transmitted field of the cavity and the fluorescence intensity is proportional to the concurrence for weak driving fields.Comment: enhanced discussion, corrected formulas, title change, 1 added figur

    Faraday spectroscopy of atoms confined in a dark optical trap

    Full text link
    We demonstrate Faraday spectroscopy with high duty cycle and sampling rate using atoms confined to a blue-detuned optical trap. Our trap consists of a crossed pair of high-charge-number hollow laser beams, which forms a dark, box-like potential. We have used this to measure transient magnetic fields in a 500-micron-diameter spot over a 400 ms time window with nearly unit duty cycle at a 500 Hz sampling rate. We use these measurements to quantify and compensate time-varying magnetic fields to ~10 nT per time sample.Comment: 6 pages, 8 figures Accepted in Phys. Rev.

    Unusual cross-sectional imaging findings in hepatic peliosis

    Get PDF
    Abstract.: Hepatic peliosis is a rare entity that represents focal, multifocal, segmental, or diffuse dilatation of liver sinusoids. Hepatic peliosis is often associated with chronic wasting diseases but also has been reported in association with anabolic, contraceptive, or other hormonal treatment, and even in context with HIV-related bacterial infections. Hepatic peliosis is usually clinically unapparent and mostly found only during autopsy, but occasionally it may lead to diagnostic problems if detected radiologically since the imaging findings in hepatic peliosis are quite variable according to the variety of its possible histologic features as well as the possibility of additional hemorrhage. We present a case of hepatic peliosis associated with bronchial carcinoma that showed moderate centripetal enhancement during the portal-venous phase on CT, pronounced venous pooling on contrast enhanced T1-weighted images acquired during the hepatic-venous phase, and bright signal on T2-weighted images, thus mimicking in some way a capillary hemangioma. We also discuss some not yet described CT and MR features of this rare entity which should be included into the differential diagnosis of atypical liver lesions in patients with the above-mentioned condition

    Magnetically-controlled velocity selection in a cold atom sample using stimulated Raman transitions

    Full text link
    We observe velocity-selective two-photon resonances in a cold atom cloud in the presence of a magnetic field. We use these resonances to demonstrate a simple magnetometer with sub-mG resolution. The technique is particularly useful for zeroing the magnetic field and does not require any additional laser frequencies than are already used for standard magneto-optical traps. We verify the effects using Faraday rotation spectroscopy.Comment: 5 pages, 6 figure

    Enhanced Spontaneous Emission Into The Mode Of A Cavity QED System

    Get PDF
    We study the light generated by spontaneous emission into a mode of a cavity QED system under weak excitation of the orthogonally polarized mode. Operating in the intermediate regime of cavity QED with comparable coherent and decoherent coupling constants, we find an enhancement of the emission into the undriven cavity mode by more than a factor of 18.5 over that expected by the solid angle subtended by the mode. A model that incorporates three atomic levels and two polarization modes quantitatively explains the observations.Comment: 9 pages, 2 figures, to appear in May 2007 Optics Letter

    Cold atom confinement in an all-optical dark ring trap

    Full text link
    We demonstrate confinement of 85^{85}Rb atoms in a dark, toroidal optical trap. We use a spatial light modulator to convert a single blue-detuned Gaussian laser beam to a superposition of Laguerre-Gaussian modes that forms a ring-shaped intensity null bounded harmonically in all directions. We measure a 1/e spin-relaxation lifetime of ~1.5 seconds for a trap detuning of 4.0 nm. For smaller detunings, a time-dependent relaxation rate is observed. We use these relaxation rate measurements and imaging diagnostics to optimize trap alignment in a programmable manner with the modulator. The results are compared with numerical simulations.Comment: 5 pages, 4 figure

    High flux cold Rubidium atomic beam for strongly coupled Cavity QED

    Full text link
    This paper presents a setup capable of producing a high-flux continuous beam of cold rubidium atoms for cavity QED experiments in the regime of strong coupling. A 2 D+D^+ MOT, loaded by rubidium getters in a dry film coated vapor cell, fed a secondary moving-molasses MOT (MM-MOT) at a rate of 1.5 x 101010^{10} atoms/sec. The MM-MOT provided a continuous beam with tunable velocity. This beam was then directed through the waist of a 280 μ\mum cavity resulting in a Rabi splitting of more than +/- 10 MHz. The presence of sufficient number of atoms in the cavity mode also enabled splitting in the polarization perpendicular to the input. The cavity was in the strong coupling regime, with parameters (g, κ\kappa, γ\gamma)/2π\pi equal to (7, 3, 6)/ 2π\pi MHz.Comment: Journal pape

    Extended calibration range for prompt photon emission in ion beam irradiation

    Full text link
    Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medical applications. On the other hand, a deeper understanding of the reactions involving gamma production is needed in order to improve the physic models of Monte Carlo codes, relevant for an accurate prediction of the prompt-gamma energy spectrum.This paper describes a calibration technique tailored for the range of energy of interest and reanalyzes the data of the interaction of a 80MeV/u fully stripped carbon ion beam with a Poly-methyl methacrylate target. By adopting the FLUKA simulation with the appropriate calibration and resolution a significant improvement in the agreement between data and simulation is reported.Comment: 4 pages, 7 figures, Submitted to JINS

    Multicenter phase II trial of preoperative induction chemotherapy followed by chemoradiation with docetaxel and cisplatin for locally advanced esophageal carcinoma (SAKK 75/02)

    Get PDF
    Background: This multicenter phase II study investigated the efficacy and feasibility of preoperative induction chemotherapy followed by chemoradiation and surgery in patients with esophageal carcinoma. Patients and methods: Patients with locally advanced resectable squamous cell carcinoma or adenocarcinoma of the esophagus received induction chemotherapy with cisplatin 75 mg/m2 and docetaxel (Taxotere) 75 mg/m2 on days 1 and 22, followed by radiotherapy of 45 Gy (25 × 1.8 Gy) and concurrent chemotherapy comprising cisplatin 25 mg/m2 and docetaxel 20 mg/m2 weekly for 5 weeks, followed by surgery. Results: Sixty-six patients were enrolled at eleven centers and 57 underwent surgery. R0 resection was achieved in 52 patients. Fifteen patients showed complete, 16 patients nearly complete and 26 patients poor pathological remission. Median overall survival was 36.5 months and median event-free survival was 22.8 months. Squamous cell carcinoma and good pathologically documented response were associated with longer survival. Eighty-two percent of all included patients completed neoadjuvant therapy and survived for 30 days after surgery. Dysphagia and mucositis grade 3/4 were infrequent (<9%) during chemoradiation. Five patients (9%) died due to surgical complications. Conclusions: This neoadjuvant, taxane-containing regimen was efficacious and feasible in patients with locally advanced esophageal cancer in a multicenter, community-based setting and represents a suitable backbone for further investigatio
    corecore