Chest X-ray Analysis With Deep Learning-Based Software as a Triage Test for Pulmonary Tuberculosis: An Individual Patient Data Meta-Analysis of Diagnostic Accuracy.
BACKGROUND: Automated radiologic analysis using computer-aided detection software (CAD) could facilitate chest X-ray (CXR) use in tuberculosis diagnosis. There is little to no evidence on the accuracy of commercially available deep learning-based CAD in different populations, including patients with smear-negative tuberculosis and people living with human immunodeficiency virus (HIV, PLWH). METHODS: We collected CXRs and individual patient data (IPD) from studies evaluating CAD in patients self-referring for tuberculosis symptoms with culture or nucleic acid amplification testing as the reference. We reanalyzed CXRs with three CAD programs (CAD4TB version (v) 6, Lunit v3.1.0.0, and qXR v2). We estimated sensitivity and specificity within each study and pooled using IPD meta-analysis. We used multivariable meta-regression to identify characteristics modifying accuracy. RESULTS: We included CXRs and IPD of 3727/3967 participants from 4/7 eligible studies. 17% (621/3727) were PLWH. 17% (645/3727) had microbiologically confirmed tuberculosis. Despite using the same threshold score for classifying CXR in every study, sensitivity and specificity varied from study to study. The software had similar unadjusted accuracy (at 90% pooled sensitivity, pooled specificities were: CAD4TBv6, 56.9% [95% confidence interval {CI}: 51.7-61.9]; Lunit, 54.1% [95% CI: 44.6-63.3]; qXRv2, 60.5% [95% CI: 51.7-68.6]). Adjusted absolute differences in pooled sensitivity between PLWH and HIV-uninfected participants were: CAD4TBv6, -13.4% [-21.1, -6.9]; Lunit, +2.2% [-3.6, +6.3]; qXRv2: -13.4% [-21.5, -6.6]; between smear-negative and smear-positive tuberculosis was: were CAD4TBv6, -12.3% [-19.5, -6.1]; Lunit, -17.2% [-24.6, -10.5]; qXRv2, -16.6% [-24.4, -9.9]. Accuracy was similar to human readers. CONCLUSIONS: For CAD CXR analysis to be implemented as a high-sensitivity tuberculosis rule-out test, users will need threshold scores identified from their own patient populations and stratified by HIV and smear status
Artificial intelligence-reported chest X-ray findings of culture-confirmed pulmonary tuberculosis in people with and without diabetes
Objectives: We applied computer-aided detection (CAD) software for chest X-ray (CXR) analysis to determine if diabetes affects the radiographic presentation of tuberculosis. Methods: From March 2017-July 2018, we consecutively enrolled adults being evaluated for pulmonary tuberculosis in Karachi, Pakistan. Participants had same-day CXR, two sputum mycobacterial cultures, and random blood glucose measurement. We identified diabetes through self-report or glucose >11.1mMol/L. We included participants with culture-confirmed tuberculosis for this analysis. We used linear regression to estimate associations between CAD-reported tuberculosis abnormality score (range 0.00 to 1.00) and diabetes, adjusting for age, body mass index, sputum smear-status, and prior tuberculosis. We also compared radiographic abnormalities between participants with and without diabetes. Results: 63/272 (23%) of included participants had diabetes. After adjustment, diabetes was associated with higher CAD tuberculosis abnormality scores (p < 0.001). Diabetes was not associated with frequency of CAD-reported radiographic abnormalities apart from cavitary disease; participants with diabetes were more likely to have cavitary disease (74.6% vs 61.2% p = 0.07), particularly non-upper zone cavitary disease (17% vs 7.8%, p = 0.09). Conclusions: CAD analysis of CXR suggests diabetes is associated with more extensive radiographic abnormalities and with greater likelihood of cavities outside upper lung zones
Diagnostic accuracy of serological tests for covid-19 : systematic review and meta-analysis
Objective
To determine the diagnostic accuracy of serological
tests for coronavirus disease-2019 (covid-19).
Design
Systematic review and meta-analysis.
Data sources
Medline, bioRxiv, and medRxiv from 1 January to 30
April 2020, using subject headings or subheadings
combined with text words for the concepts of covid-19
and serological tests for covid-19.
Eligibility criteria and data analysis
Eligible studies measured sensitivity or specificity,
or both of a covid-19 serological test compared
with a reference standard of viral culture or reverse
transcriptase polymerase chain reaction. Studies were
excluded with fewer than five participants or samples.
Risk of bias was assessed using quality assessment
of diagnostic accuracy studies 2 (QUADAS-2). Pooled
sensitivity and specificity were estimated using
random effects bivariate meta-analyses.
Main outcome measures
The primary outcome was overall sensitivity and
specificity, stratified by method of serological
testing (enzyme linked immunosorbent assays
(ELISAs), lateral flow immunoassays (LFIAs), or
chemiluminescent immunoassays (CLIAs)) and
immunoglobulin class (IgG, IgM, or both). Secondary
outcomes were stratum specific sensitivity and
specificity within subgroups defined by study or
participant characteristics, including time since
symptom onset.
Results
5016 references were identified and 40 studies
included. 49 risk of bias assessments were carried
out (one for each population and method evaluated).
High risk of patient selection bias was found in 98%
(48/49) of assessments and high or unclear risk
of bias from performance or interpretation of the
serological test in 73% (36/49). Only 10% (4/40)
of studies included outpatients. Only two studies
evaluated tests at the point of care. For each method
of testing, pooled sensitivity and specificity were not
associated with the immunoglobulin class measured.
The pooled sensitivity of ELISAs measuring IgG or
IgM was 84.3% (95% confidence interval 75.6%
to 90.9%), of LFIAs was 66.0% (49.3% to 79.3%),
and of CLIAs was 97.8% (46.2% to 100%). In all
analyses, pooled sensitivity was lower for LFIAs, the
potential point-of-care method. Pooled specificities
ranged from 96.6% to 99.7%. Of the samples used
for estimating specificity, 83% (10465/12547) were
from populations tested before the epidemic or not
suspected of having covid-19. Among LFIAs, pooled
sensitivity of commercial kits (65.0%, 49.0% to
78.2%) was lower than that of non-commercial tests
(88.2%, 83.6% to 91.3%). Heterogeneity was seen
in all analyses. Sensitivity was higher at least three
weeks after symptom onset (ranging from 69.9% to
98.9%) compared with within the first week (from
13.4% to 50.3%).
Conclusion
Higher quality clinical studies assessing the
diagnostic accuracy of serological tests for covid-19
are urgently needed. Currently, available evidence
does not support the continued use of existing point of-care serological tests.Medicine, Faculty ofNon UBCMedicine, Department ofRespiratory Medicine, Division ofReviewedFacultyResearcherPostdoctoralGraduat
Chest X-ray Analysis With Deep Learning-Based Software as a Triage Test for Pulmonary Tuberculosis: An Individual Patient Data Meta-Analysis of Diagnostic Accuracy
Background Automated radiologic analysis using computer-aided detection software (CAD) could facilitate chest X-ray (CXR) use in tuberculosis diagnosis. There is little to no evidence on the accuracy of commercially available deep learning-based CAD in different populations, including patients with smear-negative tuberculosis and people living with human immunodeficiency virus (HIV, PLWH). Methods We collected CXRs and individual patient data (IPD) from studies evaluating CAD in patients self-referring for tuberculosis symptoms with culture or nucleic acid amplification testing as the reference. We reanalyzed CXRs with three CAD programs (CAD4TB version (v) 6, Lunit v3.1.0.0, and qXR v2). We estimated sensitivity and specificity within each study and pooled using IPD meta-analysis. We used multivariable meta-regression to identify characteristics modifying accuracy. Results We included CXRs and IPD of 3727/3967 participants from 4/7 eligible studies. 17% (621/3727) were PLWH. 17% (645/3727) had microbiologically confirmed tuberculosis. Despite using the same threshold score for classifying CXR in every study, sensitivity and specificity varied from study to study. The software had similar unadjusted accuracy (at 90% pooled sensitivity, pooled specificities were: CAD4TBv6, 56.9% [95% confidence interval {CI}: 51.7-61.9]; Lunit, 54.1% [95% CI: 44.6-63.3]; qXRv2, 60.5% [95% CI: 51.7-68.6]). Adjusted absolute differences in pooled sensitivity between PLWH and HIV-uninfected participants were: CAD4TBv6, -13.4% [-21.1, -6.9]; Lunit, +2.2% [-3.6, +6.3]; qXRv2: -13.4% [-21.5, -6.6]; between smear-negative and smear-positive tuberculosis was: were CAD4TBv6, -12.3% [-19.5, -6.1]; Lunit, -17.2% [-24.6, -10.5]; qXRv2, -16.6% [-24.4, -9.9]. Accuracy was similar to human readers. Conclusions For CAD CXR analysis to be implemented as a high-sensitivity tuberculosis rule-out test, users will need threshold scores identified from their own patient populations and stratified by HIV and smear status. An individual patient data (IPD) meta-analysis found the accuracy of commercially available deep learning-based chest X-ray analysis software for detecting tuberculosis varied between studies and by patient characteristics. Diagnostic heterogeneity poses an implementation challenge for this novel technology