90 research outputs found

    High intrinsic energy resolution photon number resolving detectors

    Full text link
    Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon detector for quantum technology experiments. For a TES based on titanium and gold has been reached, at telecommunication wavelength, an unprecedented intrinsic energy resolution (0.113 eV). The uncertainties analysis of both energy resolution and photon state assignment has been discussed. The thermal properties of the superconductive device have been studied by fitting the bias curve to evaluate theoretical limit of the energy resolution

    Single-photon light detection with transition-edge sensors

    Get PDF
    Transition-Edge Sensors (TESs) are microcalorimeters that measure the energy of incident single photons by the resistance increase of a superconducting film biased within the superconducting-to-normal transition. TES are able to detect single photons from IR to X-ray with an intrinsic energy resolution and photon-number discrimination capability. Metrology, astronomy and quantum communication are the fields where these properties can be particularly useful. In this work, we report about characterization of different TESs based on Ti films. Single photons have been detected from 200nm to 800 nm working at transition temperature Tc ∼ 100 mK. Using a pulsed laser at 690nm we have demonstrated the capability to resolve up to five photons

    Towards joint reconstruction of noise and losses in quantum channels

    Get PDF
    The calibration of a quantum channel, i.e. the determination of the transmission losses affecting it, is definitely one of the principal objectives in both the quantum communication and quantum metrology frameworks. Another task of the utmost relevance is the identification, e.g. by extracting its photon number distribution, of the noise potentially present in the channel. Here we present a protocol, based on the response of a photon-number-resolving detector at different quantum efficiencies, able to accomplish both of these tasks at once, providing with a single measurement an estimate of the transmission losses as well as the photon statistics of the noise present in the exploited quantum channel. We show and discuss the experimental results obtained in the practical implementation of such protocol, with different kinds and levels of noise.Comment: 6 pages, 4 figure

    E-beam evaporated ZnO thin films: Fabrication and characterization as UV detector

    Get PDF
    partially_open5In the present paper, fabrication and structural, optical and electrical characterization of ZnO thin films grown by electron gun technique are reported and the performances of a prototype of UV photodetector based on them are illustrated. ZnO thin films, fabricated on sapphire by e-beam evaporation followed by a two-step ex situ treatment (annealing and oxidation), are polycrystalline, with a smooth surface and show very good visible transparency and an energy gap of 3.2 eV. Preliminary results on fabrication and characterization of an UV detector are reported. The Al interdigitated contacts show a Schottky behavior, which is strongly desired in view of applications since it has many advantages in the aspects of high quantum efficiency, response time, low dark current, high UV/visible contrast and possible zero-bias operation.partially_openPortesi C; Lolli L; Taralli E; Rajteri M; Monticone EPortesi, Chiara; Lolli, L; Taralli, Emanuele; Rajteri, Mauro; Monticone, Eugeni

    Self consistent, absolute calibration technique for photon number resolving detectors

    Full text link
    Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.Comment: 9 pages, 2 figure

    Quantum and classical characterization of single/few photon detectors

    Full text link
    This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we focus on photon-number-resolving detectors, discussing both the classical and quantum characterization of such devices.Comment: Quantum Matter in pres

    A Bio-Imaging Signature as a Predictor of Clinical Outcomes in Locally Advanced Pancreatic Cancer

    Get PDF
    Purpose: To evaluate the predictive value of 18F-FDG PET/CT semiquantitative parameters of the primary tumour and CA 19-9 levels assessed before treatment in patients with locally advanced pancreatic cancer (LAPC). Methods: Among one-hundred twenty patients with LAPC treated at our institution with initial chemotherapy followed by curative chemoradiotherapy (CRT) from July 2013 to January 2019, a secondary analysis with baseline 18F-FDG PET/CT was conducted in fifty-eight patients. Pre-treatment CA 19-9 level and the maximum standardized uptake value (SUVmax), metabolic tumour volume (MTV) and total lesion glycolysis (TLG) of primary tumour were measured. The receiving operating characteristics (ROC) analysis was performed to define the cut-off point of SUVmax, MTV, TLG and CA 19-9 values to use in prediction of early progression (EP), local progression (LP) and overall survival (OS). Areas under the curve (AUCs) were assessed for all variables. Post-test probability was calculated to evaluate the advantage for parameters combination. Results: For EP, CA 19-9 level > 698 U/mL resulted the best marker to identify patient at higher risk with OR of 5.96 (95% CI, 1.66–19.47; p = 0.005) and a Positive Predictive Value (PPV) of 61%. For LP, the most significant parameter was TLG (OR 9.75, 95% CI, 1.64–57.87, p = 0.012), with PPV of 83%. For OS, the most significant parameter was MTV (OR 3.12, 95% CI, 0.9–10.83, p = 0.07) with PPV of 88%. Adding consecutively each of the other parameters, PPV to identify patients at risk resulted further increased (>90%). Conclusions: Pre-treatment CA 19-9 level, as well as MTV and TLG values of primary tumour at baseline 18F-FDG PET/CT and their combination, may represent significant predictors of EP, LP and OS in LAPC patients

    A bio-imaging signature as a predictor of clinical outcomes in locally advanced pancreatic cancer

    Get PDF
    Purpose: To evaluate the predictive value of18F-FDG PET/CT semiquantitative parameters of the primary tumour and CA 19-9 levels assessed before treatment in patients with locally advanced pancreatic cancer (LAPC). Methods: Among one-hundred twenty patients with LAPC treated at our institution with initial chemotherapy followed by curative chemoradiotherapy (CRT) from July 2013 to January 2019, a secondary analysis with baseline18F-FDG PET/CT was conducted in fifty-eight patients. Pre-treatment CA 19-9 level and the maximum standardized uptake value (SUVmax), metabolic tumour volume (MTV) and total lesion glycolysis (TLG) of primary tumour were measured. The receiving operating characteristics (ROC) analysis was performed to define the cut-off point of SUVmax, MTV, TLG and CA 19-9 values to use in prediction of early progression (EP), local progression (LP) and overall survival (OS). Areas under the curve (AUCs) were assessed for all variables. Post-test probability was calculated to evaluate the advantage for parameters combination. Results: For EP, CA 19-9 level > 698 U/mL resulted the best marker to identify patient at higher risk with OR of 5.96 (95% CI, 1.66\u201319.47; p = 0.005) and a Positive Predictive Value (PPV) of 61%. For LP, the most significant parameter was TLG (OR 9.75, 95% CI, 1.64\u201357.87, p = 0.012), with PPV of 83%. For OS, the most significant parameter was MTV (OR 3.12, 95% CI, 0.9\u201310.83, p = 0.07) with PPV of 88%. Adding consecutively each of the other parameters, PPV to identify patients at risk resulted further increased (>90%). Conclusions: Pre-treatment CA 19-9 level, as well as MTV and TLG values of primary tumour at baseline18F-FDG PET/CT and their combination, may represent significant predictors of EP, LP and OS in LAPC patients

    ATHENA X-IFU Demonstration Model: First Joint Operation of the Main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

    Get PDF
    The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which work in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons
    • …