97 research outputs found
Morphologic studies of bone marrow cells exposed to the phospholipid fraction from the liver of irradiated animal, an experiment in vitro
With the purpose of revealing the biological effects of the X-ray irradiation the authors extracted phospholipids from the liver of irradiated animals and proved that this substance has the action to inhibit the growth of the bone marrow cells, the motility of pseudo-eosinophilis and the erythropoiesis in tissue culture, suggesting that the injury will mainly be induced by the toxic substances produced by irradiation.</p
Recommended from our members
Three-Dimensional Quantitative Assessment of Ablation Margins Based on Registration of Pre- and Post-Procedural MRI and Distance Map
Purpose: Contrast-enhanced MR images are widely used to confirm the adequacy of ablation margin after liver ablation for early prediction of local recurrence. However, quantitative assessment of the ablation margin by comparing pre- and post-procedural images remains challenging. We developed and tested a novel method for three-dimensional quantitative assessment of ablation margin based on non-rigid image registration and 3D distance map. Methods: Our method was tested with pre- and post-procedural MR images acquired in 21 patients who underwent image-guided percutaneous liver ablation. The two images were co-registered using non-rigid intensity-based registration. After the tumor and ablation volumes were segmented, target volume coverage, percent of tumor coverage, and Dice Similarity Coefficient were calculated as metrics representing overall adequacy of ablation. In addition, 3D distance map around the tumor was computed and superimposed on the ablation volume to identify the area with insufficient margins. For patients with local recurrences, the follow-up images were registered to the post-procedural image. Three-D minimum distance between the recurrence and the areas with insufficient margins were quantified. Results: The percent tumor coverage for all non-recurrent cases was 100%. Five cases had tumor recurrences, and the 3D distance map revealed insufficient tumor coverage or a 0-millimeter margin. It also showed that two recurrences were remote to the insufficient margin. Conclusions: Non-rigid registration and 3D distance map allows us to quantitatively evaluate the adequacy of the ablation margin after percutaneous liver ablation. The method may be useful to predict local recurrences immediately following ablation procedure
Hematopoietic cell-derived IL-15 supports NK cell development in scattered and clustered localization within the bone marrow
骨髄のNK細胞の分化に造血細胞が産生するIL-15が必須である --2種類の局在を示すNK細胞の新規分化モデル--. 京都大学プレスリリース. 2023-09-20.Natural killer (NK) cells are innate immune cells critical for protective immune responses against infection and cancer. Although NK cells differentiate in the bone marrow (BM) in an interleukin-15 (IL-15)-dependent manner, the cellular source of IL-15 remains elusive. Using NK cell reporter mice, we show that NK cells are localized in the BM in scattered and clustered manners. NK cell clusters overlap with monocyte and dendritic cell accumulations, whereas scattered NK cells require CXCR4 signaling. Using cell-specific IL-15-deficient mice, we show that hematopoietic cells, but not stromal cells, support NK cell development in the BM through IL-15. In particular, IL-15 produced by monocytes and dendritic cells appears to contribute to NK cell development. These results demonstrate that hematopoietic cells are the IL-15 niche for NK cell development in the BM and that BM NK cells are present in scattered and clustered compartments by different mechanisms, suggesting their distinct functions in the immune response
Inhibition of Hepatitis C Virus Replication and Viral Helicase by Ethyl Acetate Extract of the Marine Feather Star Alloeocomatella polycladia
Hepatitis C virus (HCV) is a causative agent of acute and chronic hepatitis, leading to the development of hepatic cirrhosis and hepatocellular carcinoma. We prepared extracts from 61 marine organisms and screened them by an in vitro fluorescence assay targeting the viral helicase (NS3), which plays an important role in HCV replication, to identify effective candidates for anti-HCV agents. An ethyl acetate-soluble fraction of the feather star Alloeocomatella polycladia exhibited the strongest inhibition of NS3 helicase activity, with an IC50 of 11.7 µg/mL. The extract of A. polycladia inhibited interaction between NS3 and RNA but not ATPase of NS3. Furthermore, the replication of the replicons derived from three HCV strains of genotype 1b in cultured cells was suppressed by the extract with an EC50 value of 23 to 44 µg/mL, which is similar to the IC50 value of the NS3 helicase assay. The extract did not induce interferon or inhibit cell growth. These results suggest that the unknown compound(s) included in A. polycladia can inhibit HCV replication by suppressing the helicase activity of HCV NS3. This study may present a new approach toward the development of a novel therapy for chronic hepatitis C
Left atrial volume predicts adverse cardiac and cerebrovascular events in patients with hypertrophic cardiomyopathy
<p>Abstract</p> <p>Aims</p> <p>To prospectively evaluate the relationship between left atrial volume (LAV) and the risk of clinical events in patients with hypertrophic cardiomyopathy (HCM).</p> <p>Methods</p> <p>We enrolled a total of 141 HCM patients with sinus rhythm and normal pump function, and 102 patients (73 men; mean age, 61 ± 13 years) who met inclusion criteria were followed for 30.8 ± 10.0 months. The patients were divided into two groups with or without major adverse cardiac and cerebrovascular events (MACCE), a composite of stroke, sudden death, and congestive heart failure. Detailed clinical and echocardiographic data were obtained.</p> <p>Results</p> <p>MACCE occurred in 24 patients (18 strokes, 4 congestive heart failure and 2 sudden deaths). Maximum LAV, minimum LAV, and LAV index (LAVI) corrected for body surface area (BSA) were significantly greater in patients with MACCE than those without MACCE (maximum LAV: 64.3 ± 25.0 vs. 51.9 ± 16.0 ml, p = 0.005; minimum LAV: 33.9 ± 15.1 vs. 26.2 ± 10.9 ml, p = 0.008; LAVI: 40.1 ± 15.4 vs. 31.5 ± 8.7 ml/mm<sup>2</sup>, p = 0.0009), while there were no differences in the other echocardiographic parameters.</p> <p>LAV/BSA of ≥ 40.4 ml/m<sup>2 </sup>to identify patients with cardiovascular complications with a sensitivity of 73% and a specificity of 88%.</p> <p>Conclusion</p> <p>LAVI may be an effective marker for detecting the risk of MACCE in patients with HCM and normal pump function.</p
Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator.
PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is preferable due to its superior soft tissue contrast. The objective of this study was to develop and evaluate an MR and US multi-modal image-guided navigation system with a needle manipulator to enable US-guided applicator placement during MR imaging (MRI)-guided percutaneous tumor ablation.METHODS:The MRI-compatible needle manipulator with US probe was installed adjacent to a 3 Tesla MRI scanner patient table. Coordinate systems for the MR image, patient table, manipulator, and US probe were all registered using an optical tracking sensor. The patient was initially scanned in the MRI scanner bore for planning and then moved outside the bore for treatment. Needle insertion was guided by real-time US imaging fused with the reformatted static MR image to enhance soft tissue contrast. Feasibility, targeting accuracy, and MR compatibility of the system were evaluated using a bovine liver and agar phantoms.RESULTS:Targeting error for 50 needle insertions was 1.6 ± 0.6 mm (mean ± standard deviation). The experiment confirmed that fused MR and US images provided real-time needle localization against static MR images with soft tissue contrast.CONCLUSIONS:The proposed MR and US multi-modal image-guided navigation system using a needle manipulator enabled accurate needle insertion by taking advantage of static MR and real-time US images simultaneously. Real-time visualization helped determine needle depth, tissue monitoring surrounding the needle path, target organ shifts, and needle deviation from the path
- …