105 research outputs found

    Successful lung-protective ventilatory management during the VV-ECMO in a severe COVID-19 pneumonia patient with extensive pneumomediastinum and subcutaneous emphysema: a case report

    Get PDF
    BACKGROUND: Ventilatory management of respiratory failure with pneumomediastinum/subcutaneous emphysema is not established. Herein, we report a case of severe COVID-19 pneumonia with extensive pneumomediastinum/subcutaneous emphysema, rescued by thorough lung-protective ventilatory management after applying the VV-ECMO. CASE PRESENTATION: A 68-year-old male with no medical history was admitted to a local hospital and diagnosed with COVID-19 pneumonia. His pulmonary parameters worsened during invasive ventilation due to the development of pneumomediastinum/subcutaneous emphysema, and then he was transferred to our hospital. On arrival, we immediately decided to apply VV-ECMO and switch to ultraprotective ventilation. After maintaining the initial ventilation with a neuromuscular blocking agent for 2 days, we gradually increased PEEP while limiting PIP to 25 cmH2O. The patient was weaned off VV-ECMO on day 10; he was transferred to the medical ward after extubation. CONCLUSIONS: Lung-protective ventilatory management should be performed thoroughly during VV-ECMO in severe COVID-19 pneumonia with pneumomediastinum/subcutaneous emphysema

    Long-term stability of the Hounsfield unit to electron density calibration curve in cone-beam computed tomography images for adaptive radiotherapy treatment planning

    Get PDF
    Aim To use cone-beam computed tomography (CBCT) images for treatment planning, the Hounsfield unit (HU)-electron density (ED) calibration table for CBCT should be stable. The purpose of this study was to verify the stability of the HU values for the CBCT system over 1 year and to evaluate the effects of variation in HU-ED calibration curves on dose calculation. Materials and Methods A tissue characterisation phantom was scanned with the field of view (FOV) of size S (FOV-S) and FOV of size M (FOV-M) using the CBCT system once a month for 1 year. A single field treatment plan was constructed on digital phantom images to validate the dose distribution using mean HU-ED calibration curves and possible variations. Results HU values for each material rod over the observation period varied with trend. The HU value of the cortical bone rod decreased by about 100 HU for the FOV-S and by about 300 HU for the FOV-M. Possible variation in the HU-ED calibration curves produced a ≤17·9% dose difference in the dose maximum in the treatment plan. Conclusions The CBCT system should be calibrated periodically for consistent dose calculation. © Cambridge University Press 2015. Aim To use cone-beam computed tomography (CBCT) images for treatment planning, the Hounsfield unit (HU)-electron density (ED) calibration table for CBCT should be stable. The purpose of this study was to verify the stability of the HU values for the CBCT system over 1 year and to evaluate the effects of variation in HU-ED calibration curves on dose calculation. Materials and Methods A tissue characterisation phantom was scanned with the field of view (FOV) of size S (FOV-S) and FOV of size M (FOV-M) using the CBCT system once a month for 1 year. A single field treatment plan was constructed on digital phantom images to validate the dose distribution using mean HU-ED calibration curves and possible variations. Results HU values for each material rod over the observation period varied with trend. The HU value of the cortical bone rod decreased by about 100 HU for the FOV-S and by about 300 HU for the FOV-M. Possible variation in the HU-ED calibration curves produced a ≤17·9% dose difference in the dose maximum in the treatment plan. Conclusions The CBCT system should be calibrated periodically for consistent dose calculation. © Cambridge University Press 2015

    Successful treatment of COVID‐19‐related acute respiratory distress syndrome with a rare blood type: A case report

    Get PDF
    Extracorporeal membrane oxygenation is indispensable for critically severe COVID-19 patients. However, it would be inapplicable to patients with a rare blood type or blood transfusion refusal. In that case, severely conservative fluid management with the sacrifice of renal functions and hydrocortisone therapy should be considered for better oxygenation

    Resistivity anisotropy measured using four probes in epitaxial graphene on silicon carbide

    Get PDF
    The electronic transport of epitaxial graphene on silicon carbide is anisotropic because of the anisotropy of the surface structure of the substrate. In this Letter, we present a new method for measuring anisotropic transport based on the van der Pauw method. This method can measure anisotropic transport on the macroscopic scale without special equipment or device fabrication. We observe an anisotropic resistivity with a ratio of maximum to minimum of 1.62. The calculated maximum mobility is 2876cm2·V-1·s-1, which is 1.43 times higher than that obtained by the standard van der Pauw method

    Population pharmacokinetic modeling of GS‐441524, the active metabolite of remdesivir, in Japanese COVID‐19 patients with renal dysfunction

    Get PDF
    腎障害患者におけるレムデシビルの薬物動態モデルを構築 --新型コロナウイルス感染症治療薬の適正使用に向けて--. 京都大学プレスリリース. 2021-11-25.Remdesivir, a prodrug of the nucleoside analog GS-441524, plays a key role in the treatment of coronavirus disease 2019 (COVID-19). However, owing to limited information on clinical trials and inexperienced clinical use, there is a lack of pharmacokinetic (PK) data in patients with COVID-19 with special characteristics. In this study, we aimed to measure serum GS-441524 concentrations and develop a population PK (PopPK) model. Remdesivir was administered at a 200 mg loading dose on the first day followed by 100 mg from day 2, based on the package insert, in patients with an estimated glomerular filtration rate (eGFR) greater than or equal to 30 ml/min. In total, 190 concentrations from 37 Japanese patients were used in the analysis. The GS-441524 trough concentrations were significantly higher in the eGFR less than 60 ml/min group than in the eGFR greater than or equal to 60 ml/min group. Extracorporeal membrane oxygenation in four patients hardly affected the total body clearance (CL) and volume of distribution (Vd) of GS-441524. A one-compartment model described serum GS-441524 concentration data. The CL and Vd of GS-441524 were significantly affected by eGFR readjusted by individual body surface area and age, respectively. Simulations proposed a dose regimen of 200 mg on day 1 followed by 100 mg once every 2 days from day 2 in patients with an eGFR of 30 ml/min or less. In conclusion, we successfully established a PopPK model of GS-441524 using retrospectively obtained serum GS-441524 concentrations in Japanese patients with COVID-19, which would be helpful for optimal individualized therapy of remdesivir
    corecore