163 research outputs found

    Revisiting chameleon gravity - thin-shells and no-shells with appropriate boundary conditions

    Full text link
    We derive analytic solutions of a chameleon scalar field ϕ\phi that couples to a non-relativistic matter in the weak gravitational background of a spherically symmetric body, paying particular attention to a field mass mAm_A inside of the body. The standard thin-shell field profile is recovered by taking the limit mArcm_A*r_c \to \infty, where rcr_c is a radius of the body. We show the existence of "no-shell" solutions where the field is nearly frozen in the whole interior of the body, which does not necessarily correspond to the "zero-shell" limit of thin-shell solutions. In the no-shell case, under the condition mArc1m_A*r_c \gg 1, the effective coupling of ϕ\phi with matter takes the same asymptotic form as that in the thin-shell case. We study experimental bounds coming from the violation of equivalence principle as well as solar-system tests for a number of models including f(R)f(R) gravity and find that the field is in either the thin-shell or the no-shell regime under such constraints, depending on the shape of scalar-field potentials. We also show that, for the consistency with local gravity constraints, the field at the center of the body needs to be extremely close to the value ϕA\phi_A at the extremum of an effective potential induced by the matter coupling.Comment: 14 pages, no figure

    Efficacy of Bidens pilosa Extract against Herpes Simplex Virus Infection In Vitro and In Vivo

    Get PDF
    The development of strains of herpes simplex virus (HSV) resistant to drugs has been reported among the immunocompromised patients. Thus, there is a need to develop new therapeutic agents for HSV infections. We evaluated the anti-HSV activity of Bidens pilosa (B. pilosa), a tropical weed, in tissue culture cells and a mouse model. B. pilosa extract showed potent virucidal activity. It inhibited plaque formation and suppressed virus yield in Vero and RAW 264.7 cells infected with HSV-1 and HSV-2. Both the binding of virus to host cells and penetration of virus into cells were also blocked by B. pilosa. Furthermore, B. pilosa was effective against thymidine kinase-deficient and phosphonoacetate-resistant HSV-1 strains. B. pilosa treatment increased the survival rate of HSV-infected mice and limited the development of skin lesions. Our results indicate that B. pilosa has anti-HSV activity and is thus a potentially useful medical plant for treatment of HSV infection

    Activation Pattern of Langerhans Cells in the Afferent and Efferent Phases of Contact Hypersensitivity

    Get PDF
    Langerhans cells are MHC class II (Ia) positive antigen- presenting cells that play a crucial role in the induction of contact hypersensitivity (CHS). The topical application of a hapten modifies the cell surface moieties of Langerhans cells, and activates Langerhans cells to increase their size and Ia intensity. The haptenated and activated Langerhans cells emigrate from the epidermis and thus the in situ density of Langerhans cells usually decreases during 24-48h after the hapten application in CHS. To determine whether the early activation pattern of Langerhans cells is different between the afferent phase and the efferent phase of CHS, we compared the density and morphologic changes of Langerhans cells in CHS to trinitrochlorobenzene using nonsensitized and sensitized mice. We found that the application of a hapten induces more significant enlargement of Langerhans cell size in the afferent phase than in the efferent phase, whereas the reduction of Langerhans cell density is more marked in the efferent than in the afferent phase of CHS. Moreover, topical immunosuppressive drugs inhibit the in situ activation of Langerhans cells

    閉塞型睡眠時無呼吸症候群患者における早朝の高分子量フォンウィルブランド因子減少は無呼吸の重症度を反映する

    Get PDF
    Plasma von Willebrand factor (VWF), produced in and released from vascular endothelial cells by various stimuli including hypoxia, induces platelet aggregation under high shear stress and plays dual pivotal roles in haemostasis and thrombosis within arterioles, which are regulated by the size of vWF multimers (VWFMs). Patients with obstructive sleep apnoea (OSA) have increased risk of thrombotic cardiovascular events, but the pathogenesis is unclear. We examined the relationship between VWF and OSA by measuring VWF antigen (VWF:Ag), VWFMs, VWF collagen binding activity (VWF:CB) and a disintegrin-like, metalloproteinase, and thrombospiondin type 1 motifs 13. A total of 58 OSA patients were enrolled. Blood samples were collected before sleep, after sleep, and after one night of nasal continuous positive airway pressure therapy. Based on VWFM analysis, OSA patients were classified into three groups; consistently normal VWFMs (group 1, n=29), increased high molecular weight (HMW)-VWFMs at 06:00 h (group 2, n=18), and decreased or absent HMW-VWFMs at 06:00 h (group 3, n=11). Patients in group 3 had significantly worse apnoea/hypopnoea index; VWF:CB followed a similar pattern. We observed a significant decrease in platelet count between 21:00 h and 06:00 h in OSA patients, potentially associated with reduced larger VWFMs together with decreased VWF:Ag levels. Severe OSA may contribute to an arterial pro-thrombotic state.博士(医学)・乙第1294号・平成24年5月28日Copyright © 2012 by the European Respiratory Societ

    Optical impression method to measure three-dimensional position and orientation of dental implants using an optical tracker

    Full text link
    Objectives: The aim of this study was to devise an optical impression method that could make impressions of dental implants accurately and rapidly. Materials and methods: Four paper markers (4 × 3 mm, 8 × 6 mm, 16 × 12 mm, and 24 × 18 mm) and one titanium marker (8 × 6 mm) were prepared to determine the measuring accuracy of the three-dimensional optical tracker. For a proposed and conventional impression taking method, we compared the reproduction accuracies of the positions and orientations of dental implants and the times to obtain impressions. Finally, we fabricated computer-aided designing (CAD)/computer-aided manufacturing (CAM) superstructure frameworks to determine the adaptation accuracy. Results: The 8 × 6-mm titanium marker was optimal among the prepared markers. Dental implants made by the proposed and conventional impression taking methods had measurement errors of 71 ± 31 μm and 32 ± 18 μm, respectively. The proposed method took a significantly shorter time to obtain an impression than did the conventional method. The connection between the CAD/CAM superstructure frameworks and four implant analogs had uplifts of 55 ± 10 μm, 94 ± 35 μm, 2 ± 1 μm, and 66 ± 3 μm. Conclusion: Our proposed method and fabricated titanium markers enabled us to measure the positions and orientations of dental implants both accurately and rapidly. We then used the reproducible measurement results for the positions and orientations of the dental implants to fabricate CAD/CAM superstructure frameworks within an acceptable accuracy range. © 2012 John Wiley & Sons A/S.This is the pre-peer reviewed version of the following article: Ono S., Yamaguchi S., Kusumoto N., et al. Optical impression method to measure three-dimensional position and orientation of dental implants using an optical tracker. Clinical Oral Implants Research 24, 1117 (2013), which has been published in final form at https://doi.org/10.1111/j.1600-0501.2012.02519.x.. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving

    Effects of implant–abutment connection type and inter-implant distance on inter-implant bone stress and microgap: Three-dimensional finite element analysis

    Get PDF
    The attainment of a good aesthetic outcome in dental implant treatment requires inter-implant papilla reconstruction, which is very difficult to perform. Maintenance of the inter-implant bone is essential for maintenance of the inter-implant papilla. The aim of this study was to investigate the mechanical influences of the implant–abutment connection type and inter-implant distance on the inter-implant bone by using three-dimensional finite element analysis. Three computer-aided design models of two-piece implants were designed: external connection (EC), internal connection (IC), and conical connection (CC). In each model, two identical implants were placed with inter-implant distances of 3.0, 2.5, and 2.0 mm. The maximum principal stress and microgap were evaluated. The stress values of the inter-implant bone decreased in the following order: IC, EC, and CC. The microgap decreased in the following order: EC, IC, and CC. Regardless of the type of implant– abutment connection, the stress of the inter-implant bone increased as the inter-implant distance decreased. The microgap barely changed as the inter-implant distance decreased. A CC implant is a mechanically advantageous implant–abutment connection type for maintenance of the inter-implant bone. With an inter-implant distance of less than 3.0 mm, use of a CC implant might suppress absorption of the inter-implant bone.Matsuoka T., Nakano T., Yamaguchi S., et al. Effects of implant–abutment connection type and inter-implant distance on inter-implant bone stress and microgap: Three-dimensional finite element analysis. Materials 14, 2421 (2021); https://doi.org/10.3390/ma14092421

    Nocturnal hypoxic stress activates invasive ability of monocytes in patients with obstructive sleep apnea syndrome

    Get PDF
    Backgrounds: Obstructive sleep apnea syndrome (OSAS) is known to be a risk factor of cardiovascular events. However, the precise mechanism has not been fully elucidated. OSAS-induced hypoxic stress may promote the production of inflammatory cytokines and chemokines by monocytes, which has a crucial role in the development of atherosclerosis. In addition, adhesion to the vascular endothelium and transendothelial migration of monocytes are considered to induce atherosclerosis. The aim of this study was to investigate the effects of hypoxic stress on the invasive ability of monocytes in OSAS. Methods; Twenty-one male OSAS patients and 17 male healthy control subjects, age- and body mass index-matched, were enrolled. Venous blood samples were collected not only before and after sleep but also after CPAP titration for the purpose of monocyte isolation. The invasive ability of monocytes was evaluated by counting the number of invasive cells using a BD BioCoat Matrigel Invasion Chamber. Results; The number of cells which represents invasive ability was significantly higher in OSAS patients as compared to control subjects in the early morning (p<0.001). Invasive ability in the early morning was significantly elevated as compared to that before sleep in OSAS patients (p<0.001), and it was positively correlated with oxygen desaturation index (p<0.05). CPAP titration led to alleviation of the invasive ability (p<0.001). Conclusions; The results indicate that OSAS-induced hypoxic stress activates the invasive ability of monocytes, and that this phenomenon observed during sleep may contribute to the development of atherosclerosis in OSAS.The definitive version is available at " http://dx.doi.org/10.1111/j.1440-1843.2009.01540.x "アジア太平洋呼吸器学会(APSR:Asia Pacific Society of Respirology)第1回最優秀論文賞「Fukuchi Award」受賞論
    corecore