343 research outputs found

    Application of Scan-less Two-Dimensional Confocal Microscopy Based on a Combination of Confocal Slit With Wavelength/Space Conversion

    Get PDF
    Confocal laser microscope (CLM) has been widely used in the fields of the non-contact surface topography, biomedical imaging, and other applications, because the confocality gives two-dimensional (2D) optical-sectioning or three-dimensional (3D) imaging capability with the depth selectivity. Combination of line-focused CLM with one-dimensional (1D) spectral encoding CLM enables us to obtain the 2D confocal image without the need for the mechanical scanning. So-called scan-less 2D CLM is a unique imaging modality, however, there are no attempts to apply for practical application. In this paper, we constructed scan-less 2D CLM with the image acquisition time of 0.23 ms, the lateral resolution of 1.2 µm, the depth resolution of 2.4 µm, and apply it for different kinds of application to evaluate its practical potential

    Multicascade-linked synthetic wavelength digital holography using an optical-comb-referenced frequency synthesizer

    Full text link
    Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrapping ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., synthetic wavelength DH, can expand the axial range up to a few tens of microns, this method is still insufficient for practical applications. In this article, a tunable external cavity laser diode phase-locked to an optical frequency comb, namely, an optical-comb-referenced frequency synthesizer, is effectively used for multiple synthetic wavelengths within the range of 32 um to 1.20 m. A multiple cascade link of the phase images among an optical wavelength (= 1.520 um) and 5 different synthetic wavelengths (= 32.39 um, 99.98 um, 400.0 um, 1003 um, and 4021 um) enables the shape measurement of a reflective millimeter-sized stepped surface with the axial resolution of 34 nm. The axial dynamic range, defined as the ratio of the maximum axial range (= 0.60 m) to the axial resolution (= 34 nm), achieves 1.7*10^8, which is much larger than that of previous synthetic wavelength DH. Such a wide axial dynamic range capability will further expand the application field of DH for large objects with meter dimensions.Comment: 19 pages, 7 figure

    Growth of the Cellular Slime Mold, Dictyostelium discoideum

    Full text link
    corecore