9 research outputs found

    Prediction of the Aerothermodynamic Environment of the Huygens Probe

    Get PDF
    An investigation of the aerothermodynamic environment of the Huygens entry probe has been conducted. A Monte Carlo simulation of the trajectory of the probe during entry into Titan's atmosphere was performed to identify a worst-case heating rate trajectory. Flowfield and radiation transport computations were performed at points along this trajectory to obtain convective and radiative heat-transfer distributions on the probe's heat shield. This investigation identified important physical and numerical factors, including atmospheric CH4 concentration, transition to turbulence, numerical diffusion modeling, and radiation modeling, which strongly influenced the aerothermodynamic environment

    Systems Analysis for a Venus Aerocapture Mission

    Get PDF
    Previous high level analysis has indicated that significant mass savings may be possible for planetary science missions if aerocapture is employed to place a spacecraft in orbit. In 2001 the In-Space Propulsion program identified aerocapture as one of the top three propulsion technologies for planetary exploration but that higher fidelity analysis was required to verify the favorable results and to determine if any supporting technology gaps exist that would enable or enhance aerocapture missions. A series of three studies has been conducted to assess, from an overall system point of view, the merit of using aerocapture at Titan, Neptune and Venus. These were chosen as representative of a moon with an atmosphere, an outer giant gas planet and an inner planet. The Venus mission, based on desirable science from plans for Solar System Exploration and Principal Investigator proposals, to place a spacecraft in a 300km polar orbit was examined and the details of the study are presented in this paper

    Cassini/Huygens Probe Entry, Descent, and Landing (EDL) at Titan Independent Technical Assessment

    Get PDF
    Starting in January 2004, the NESC has received several communications from knowledgeable technical experts at NASA expressing shared concerns (mainly at the Langley Research Center (LaRC) and Ames Research Center (ARC)) about Huygens mission success. It was suggested that NASA become more technically involved directly in the analysis of Huygens' entry, descent and landing (EDL) focusing on the parachute deployment trigger performance and the resultant effects on the operation of the parachute system, and the determination of the radiative heating environment at Titan by ESA and the corresponding thermal protection system (TPS) response. A NESC Team was formed and tasked to provide an independent assessment of these concerns. The results of that assessment are documented in this report

    NOMENCLATURE

    No full text
    Convective and radiative heating environments have been computed for a three-dimensional ellipsled configuration which would perform an aerocapture maneuver at Neptune. This work was performed as part of a one-year Neptune aerocapture spacecraft systems study that also included analyses of trajectories, atmospheric modeling, aerodynamics, structural design, and other disciplines. Complementary heating analyses were conducted by separate teams using independent sets of aerothermodynamic modeling tools (i.e. Navier-Stokes and radiation transport codes). Environments were generated for a large 5.50 m length ellipsled and a small 2.88 m length ellipsled. Radiative heating was found to contribute up to 80 % of the total heating rate at the ellipsled nose depending on the trajectory point. Good agreement between convective heating predictions from the two Navier-Stokes solvers was obtained. However, the radiation analysis revealed several uncertainties in the computational models employed in both sets of codes, as well as large differences between the predicted radiative heating rates

    Preliminary Convective-Radiative Heating Environments for a Neptune Aerocapture Mission

    No full text
    Convective and radiative heating environments have been computed for a three-dimensional ellipsled configuration which would perform an aerocapture maneuver at Neptune. This work was performed as part of a one-year Neptune aerocapture spacecraft systems study that also included analyses of trajectories, atmospheric modeling, aerodynamics, structural design, and other disciplines. Complementary heating analyses were conducted by separate teams using independent sets of aerothermodynamic modeling tools (i.e. Navier-Stokes and radiation transport codes). Environments were generated for a large 5.50 m length ellipsled and a small 2.88 m length ellipsled. Radiative heating was found to contribute up to 80% of the total heating rate at the ellipsled nose depending on the trajectory point. Good agreement between convective heating predictions from the two Navier-Stokes solvers was obtained. However, the radiation analysis revealed several uncertainties in the computational models employed in both sets of codes, as well as large differences between the predicted radiative heating rates
    corecore