157 research outputs found
EEG resting-state networks in Alzheimer’s disease associated with clinical symptoms
Alzheimer’s disease (AD) is a progressive neuropsychiatric disease affecting many elderly people and is characterized by progressive cognitive impairment of memory, visuospatial, and executive functions. As the elderly population is growing, the number of AD patients is increasing considerably. There is currently growing interest in determining AD’s cognitive dysfunction markers. We used exact low-resolution-brain-electromagnetic-tomography independent-component-analysis (eLORETA-ICA) to assess activities of five electroencephalography resting-state-networks (EEG-RSNs) in 90 drug-free AD patients and 11 drug-free patients with mild-cognitive-impairment due to AD (ADMCI). Compared to 147 healthy subjects, the AD/ADMCI patients showed significantly decreased activities in the memory network and occipital alpha activity, where the age difference between the AD/ADMCI and healthy groups was corrected by linear regression analysis. Furthermore, the age-corrected EEG-RSN activities showed correlations with cognitive function test scores in AD/ADMCI. In particular, decreased memory network activity showed correlations with worse total cognitive scores for both Mini-Mental-State-Examination (MMSE) and Alzheimer’s Disease-Assessment-Scale-cognitive-component-Japanese version (ADAS-J cog) including worse sub-scores for orientation, registration, repetition, word recognition and ideational praxis. Our results indicate that AD affects specific EEG-RSNs and deteriorated network activity causes symptoms. Overall, eLORETA-ICA is a useful, non-invasive tool for assessing EEG-functional-network activities and provides better understanding of the neurophysiological mechanisms underlying the disease
CMB polarimetry with BICEP: instrument characterization, calibration, and performance
BICEP is a ground-based millimeter-wave bolometric array designed to target
the primordial gravity wave signature on the polarization of the cosmic
microwave background (CMB) at degree angular scales. Currently in its third
year of operation at the South Pole, BICEP is measuring the CMB polarization
with unprecedented sensitivity at 100 and 150 GHz in the cleanest available 2%
of the sky, as well as deriving independent constraints on the diffuse
polarized foregrounds with select observations on and off the Galactic plane.
Instrument calibrations are discussed in the context of rigorous control of
systematic errors, and the performance during the first two years of the
experiment is reviewed.Comment: 12 pages, 15 figures, updated version of a paper accepted for
Millimeter and Submillimeter Detectors and Instrumentation for Astronomy IV,
Proceedings of SPIE, 7020, 200
Absolute polarization angle calibration using polarized diffuse Galactic emission observed by BICEP
We present a method of cross-calibrating the polarization angle of a
polarimeter using BICEP Galactic observations. \bicep\ was a ground based
experiment using an array of 49 pairs of polarization sensitive bolometers
observing from the geographic South Pole at 100 and 150 GHz. The BICEP
polarimeter is calibrated to +/-0.01 in cross-polarization and less than +/-0.7
degrees in absolute polarization orientation. BICEP observed the temperature
and polarization of the Galactic plane (R.A= 100 degrees ~ 270 degrees and Dec.
= -67 degrees ~ -48 degrees). We show that the statistical error in the 100 GHz
BICEP Galaxy map can constrain the polarization angle offset of WMAP Wband to
0.6 degrees +\- 1.4 degrees. The expected 1 sigma errors on the polarization
angle cross-calibration for Planck or EPIC are 1.3 degrees and 0.3 degrees at
100 and 150 GHz, respectively. We also discuss the expected improvement of the
BICEP Galactic field observations with forthcoming BICEP2 and Keck
observations.Comment: 13 pages, 10 figures and 2 tables. To appear in Proceedings of SPIE
Astronomical Telescopes and Instrumentation 201
Artificial placenta support of extremely preterm ovine fetuses at the border of viability for up to 336 hours with maintenance of systemic circulation but reduced somatic and organ growth
Introduction: Artificial placenta therapy (APT) is an experimental life support system to improve outcomes for extremely preterm infants (EPI) less than 1,000 g by obviating the need for pulmonary gas exchange. There are presently no long-term survival data for EPI supported with APT. To address this, we aimed to maintain 95d-GA (GA; term-150d) sheep fetuses for up to 2 weeks using our APT system.Methods: Pregnant ewes (n = 6) carrying singleton fetuses underwent surgical delivery at 95d GA. Fetuses were adapted to APT and maintained for up to 2 weeks with constant monitoring of key physiological parameters and extensive time-course blood and urine sampling, and ultrasound assessments. Six age-matched in-utero fetuses served as controls. Data were tested for group differences with ANOVA.Results: Six APT Group fetuses (100%) were adapted to APT successfully. The mean BW at the initiation of APT was 656 ± 42 g. Mean survival was 250 ± 72 h (Max 336 h) with systemic circulation and key physiological parameters maintained mostly within normal ranges. APT fetuses had active movements and urine output constantly exceeded infusion volume over the experiment. At delivery, there were no differences in BW (with edema in three APT group animals), brain weight, or femur length between APT and in-utero Control animals. Organ weights and humerus lengths were significantly reduced in the APT group (p < 0.05). Albumin, IGF-1, and phosphorus were significantly decreased in the APT group (p < 0.05). No cases of positive blood culture were detected.Conclusion: We report the longest use of APT to maintain extremely preterm fetuses to date. Fetal systemic circulation was maintained without infection, but growth was abnormal. This achievement suggests a need to focus not only on cardiovascular stability and health but also on the optimization of fetal growth and organ development. This new challenge will need to be overcome prior to the clinical translation of this technology
Involvement of (pro)renin receptor in the glomerular filtration barrier
(Pro)renin receptor-bound prorenin not only causes the generation of angiotensin II via the nonproteolytic activation of prorenin, it also activates the receptor’s own intracellular signaling pathways independent of the generated angiotensin II. Within the kidneys, the (pro)renin receptor is not only present in the glomerular mesangium, it is also abundant in podocytes, which play an important role in the maintenance of the glomerular filtration barrier. Recent in vivo studies have demonstrated that the overexpression of the (pro)renin receptor to a degree similar to that observed in hypertensive rat kidneys leads to slowly progressive nephropathy with proteinuria. In addition, the handle region peptide, which acts as a decoy peptide and competitively inhibits the binding of prorenin to the receptor, is more beneficial than an angiotensin-converting enzyme inhibitor with regard to alleviating proteinuria and glomerulosclerosis in experimental animal models of diabetes and essential hypertension. Thus, the (pro)renin receptor may be upregulated in podocytes under hypertensive conditions and may contribute to the breakdown of the glomerular filtration barrier
Recommended from our members
Characterization of the BICEP Telescope for High-precision Cosmic Microwave Background Polarimetry
The Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment was designed specifically to search for the signature of inflationary gravitational waves in the polarization of the cosmic microwave background (CMB). Using a novel small-aperture refractor and 49 pairs of polarization-sensitive bolometers, BICEP has completed three years of successful observations at the South Pole beginning in 2006 February. To constrain the amplitude of the inflationary B-mode polarization, which is expected to be at least 7 orders of magnitude fainter than the 3 K CMB intensity, precise control of systematic effects is essential. This paper describes the characterization of potential systematic errors for the BICEP experiment, supplementing a companion paper on the initial cosmological results. Using the analysis pipelines for the experiment, we have simulated the impact of systematic errors on the B-mode polarization measurement. Guided by these simulations, we have established benchmarks for the characterization of critical instrumental properties including bolometer relative gains, beam mismatch, polarization orientation, telescope pointing, sidelobes, thermal stability, and timestream noise model. A comparison of the benchmarks with the measured values shows that we have characterized the instrument adequately to ensure that systematic errors do not limit BICEP's two-year results, and identifies which future refinements are likely necessary to probe inflationary B-mode polarization down to levels below a tensor-to-scalar ratio r = 0.1.Astronom
The influence of implantation techniques on lesion oriented-outcomes in Absorb BVS and Xience EES lesions treated in routine clinical practice at complete three year follow-up: AIDA trial QCA substudy
It has been hypothesized that dedicated optimized Absorb BVS implantation techniques might mitigate the risk of adverse events such as target vessel
Three lateral osteotomy designs for bilateral sagittal split osteotomy: biomechanical evaluation with three-dimensional finite element analysis
<p>Abstract</p> <p>Background</p> <p>The location of the lateral osteotomy cut during bilateral sagittal split osteotomy (BSSO) varies according to the surgeon's preference, and no consensus has been reached regarding the ideal location from the perspective of biomechanics. The purpose of this study was to evaluate the mechanical behavior of the mandible and screw-miniplate system among three lateral osteotomy designs for BSSO by using three-dimensional (3-D) finite element analysis (FEA).</p> <p>Methods</p> <p>The Trauner-Obwegeser (TO), Obwegeser (Ob), and Obwegeser-Dal Pont (OD) methods were used for BSSO. In all the FEA simulations, the distal segments were advanced by 5 mm. Each model was fixed by using miniplates. These were applied at four different locations, including along Champy's lines, to give 12 different FEA miniplate fixation methods. We examined these models under two different loads.</p> <p>Results</p> <p>The magnitudes of tooth displacement, the maximum bone stress in the vicinity of the screws, and the maximum stress on the screw-miniplate system were less in the OD method than in the Ob and TO methods at all the miniplate locations. In addition, Champy's lines models were less than those at the other miniplate locations.</p> <p>Conclusions</p> <p>The OD method allows greater mechanical stability of the mandible than the other two techniques. Further, miniplates placed along Champy's lines provide greater mechanical advantage than those placed at other locations.</p
Mechanisms for the anti-obesity actions of bofutsushosan in high-fat diet-fed obese mice
- …