297 research outputs found

    CEUS LI-RADS: a pictorial review

    Get PDF
    Contrast-enhanced ultrasound (CEUS) greatly improved the diagnostic accuracy of US in the detection and characterization of focal liver lesions (FLLs), and it is suggested and often included in many international guidelines as an important diagnostic tool in the imaging work-up of cirrhotic patients at risk for developing hepatocellular carcinoma (HCC). In particular, CEUS Liver Imaging Reporting and Data System (LI-RADS) provides standardized terminology, interpretation, and reporting for the diagnosis of HCC. The aim of this pictorial essay is to illustrate CEUS features of nodules discovered at US in cirrhotic liver according to LI-RADS categorization

    Infantile nystagmus syndrome: Broadening the high-foveation-quality field with contact lenses

    Get PDF
    We investigated the effects of contact lenses in broadening and improving the high-foveation-quality field in a subject with infantile nystagmus syndrome (INS). A high-speed, digitized video system was used for the eye-movement recording. The subject was asked to fixate a far target at different horizontal gaze angles with contact lenses inserted. Data from the subject while fixating at far without refractive correction and at near (at a convergence angle of 60 PD), were used for comparison. The eXpanded Nystagmus Acuity Function (NAFX) was used to evaluate the foveation quality at each gaze angle. Contact lenses broadened the high-foveation-quality range of gaze angles in this subject. The broadening was comparable to that achieved during 60 PD of convergence although the NAFX values were lower. Contact lenses allowed the subject to see “more” (he had a wider range of high-foveation-quality gaze angles) and “better” (he had improved foveation at each gaze angle). Instead of being contraindicated by INS, contact lenses emerge as a potentially important therapeutic option. Contact lenses employ afferent feedback via the ophthalmic division of the V cranial nerve to damp INS slow phases over a broadened range of gaze angles. This supports the proprioceptive hypothesis of INS improvement

    New frontiers in liver ultrasound: From mono to multi parametricity

    Get PDF
    Modern liver ultrasonography (US) has become a "one-stop shop " able to provide not only anatomic and morphologic but also functional information about vascularity, stiffness and other various liver tissue properties. Modern US techniques allow a quantitative assessment of various liver diseases. US scanning is no more limited to the visualized plane, but three-dimensional, volumetric acquisition and consequent post-processing are also possible. Further, US scan can be consistently merged and visualized in real time with Computed Tomography and Magnetic Resonance Imaging examinations. Effective and safe microbubble-based contrast agents allow a real time, dynamic study of contrast kinetic for the detection and characterization of focal liver lesions. Ultrasound can be used to guide loco-regional treatment of liver malignancies and to assess tumoral response either to interventional procedures or medical therapies. Microbubbles may also carry and deliver drugs under ultrasound exposure. US plays a crucial role in diagnosing, treating and monitoring focal and diffuse liver disease. On the basis of personal experience and literature data, this paper is aimed to review the main topics involving recent advances in the field of liver ultrasound

    Focal Pancreatic Lesions: Role of Contrast-Enhanced Ultrasonography

    Get PDF
    The introduction of contrast-enhanced ultrasonography (CEUS) has led to a significant improvement in the diagnostic accuracy of ultrasound in the characterization of a pancreatic mass. CEUS, by using a blood pool contrast agent, can provide dynamic information concerning macro- and micro-circulation of focal lesions and of normal parenchyma, without the use of ionizing radiation. On the basis of personal experience and literature data, the purpose of this article is to describe and discuss CEUS imaging findings of the main solid and cystic pancreatic lesions with varying prevalence

    Splenic hemangiomas: contrast-enhanced sonographic findings

    Get PDF
    Objectives-The purpose of this study was to illustrate the baseline appearance and enhancement patterns of splenic hemangiomas on contrast-enhanced sonography. Methods-Two experienced radiologists retrospectively reviewed by consensus baseline and contrast-enhanced sonographic examinations of 27 patients (14 women and 13 men; mean age, 58.7 years) with 27 splenic hemangiomas (mean size, 2 cm) confirmed by splenectomy, biopsy, computed tomography, and magnetic resonance imaging and follow-up. Results-On baseline sonography, 77.8% of the lesions showed a homogeneous echo texture that was mainly hyperechoic. Color Doppler imaging did not show any signal in 81.5% of the cases. After contrast agent injection, 59.2% of the splenic hemangiomas showed different degrees of contrast enhancement in the arterial phase followed by isoenhancement in the late parenchymal phase. Among these, 2 hemangiomas showed peripheral globular enhancement in the arterial phase, followed by progressive centripetal fill-in. In 29.6% of the cases, some degree of contrast enhancement was appreciable, but the hemangiomas remained substantially hypoechoic throughout the contrast-enhanced sonographic examinations, whereas in 11.1%, the combination of contrast enhancement in the arterial phase followed by wash-out in the late parenchymal phase was evident. Conclusions-Isoechogenicity to spleen parenchyma in all phases is the most frequent typical enhancement pattern of splenic hemangiomas observed on contrast-enhanced sonography. Nevertheless, these lesions may show atypical contrast enhancement patterns; therefore, further assessment with cross-sectional techniques is needed

    Focal nodular hyperplasia: a weight-based, intraindividual comparison of gadobenate dimeglumine and gadoxetate disodium-enhanced MRI

    Get PDF
    PURPOSE: We aimed to qualitatively and quantitatively compare the enhancement pattern of focal nodular hyperplasia after gadobenate dimeglumine and gadoxetate disodium injection in the same patient. METHODS: 1.5 T magnetic resonance imaging (MRI) examinations of 16 patients with 21 focal nodular hyperplasias studied after the injection of both contrast media were evaluated. Both MRI studies were performed in all patients. A qualitative analysis was performed evaluating each lesion in all phases. For quantitative analysis we calculated signal intensity ratio, lesion-to-liver contrast ratio and liver parenchyma signal intensity gain on hepatobiliary phase. Statistical analysis was performed with the Wilcoxon sign-rank test for clustered paired data and the McNemar test for paired frequencies. A P value < 0.05 was considered statistically significant. RESULTS: At qualitative analysis no statistically significant differences were evident during any of the contrast-enhanced phases. Signal intensity ratio (P = 0.048), lesion-to-liver contrast ratio (P = 0.032) and liver parenchyma signal intensity gain (P = 0.012) were significantly higher on hepatobiliary phase after gadoxetate disodium injection. CONCLUSION: There were no significant differences in the MRI findings of focal nodular hyperplasia after the injection of a weight-based dose of either gadobenate dimeglumine or gadoxetate disodium

    Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    Get PDF
    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US)

    Imaging findings of hepatic focal nodular hyperplasia in men and women: are they really different?

    Get PDF
    Purpose This study was undertaken to compare the imaging findings of focal nodular hyperplasia (FNH) in men and women, as seen on multidetector computed tomography (MDCT), magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS). Materials and methods Two radiologists reviewed 195 imaging studies (17 MDCT, 81 MRI and 97 CEUS examinations) pertaining to 111 FNHs (mean size 3 cm) in 91 patients (mean age 39 years). For each lesion, the readers assessed size, location, echogenicity, attenuation, or signal intensity in comparison with adjacent liver parenchyma on both unenhanced and postcontrast images. Results Eighty-nine FNHs (mean size 3.1 cm) were observed in 73 women (mean age 37.9 years) and 22 FNHs (mean size 2.7 cm) in 18 men (mean age 41.2 years). No statistically significant differences were found between men and women in terms of age, FNH lesions per patient (1.22 and 1.21, respectively), size, baseline and enhancement pattern on MRI, CEUS and MDCT (p < 0.05). A central scar in FNHs was depicted in 4/18 (22.2 %) men and 16/63 (25.4 %) women on MRI (p < 0.05), and in 1/2 (50 %) men and 7/15 (46.7 %) women on MDCT (p < 0.05), whereas a spoke-wheel pattern, central scar, and/or feeding vessel were seen in 5/17 (29.4 %) men and 22/80 (27.5 %) women on CEUS (p < 0.05). Conclusions Our results did not show any differences in imaging features, age of occurrence and size of FNH between men and women
    corecore