1,440 research outputs found

    Comparison of Internal and Total Optical Aberrations for 2 Aberrometers: iTrace and OPD Scan

    Get PDF
    PURPOSE: To compare and evaluate the total and internal aberrations measured by two aberrometers: the laser ray tracing aberrometer (iTrace, Tracey Technology) and the automatic retinoscope aberrometer (OPD Scan, Nidek). METHODS: A total of 54 healthy eyes were enrolled in the study. Following pupil dilation, aberrations were measured with the iTrace and OPD Scan. We compared the aberrations obtained from measurements obtained at pupillary diameters of 4 mm and 6 mm with the OPD Scan and iTrace. Aberrations of internal optics and total aberrations were compared for the two aberrometers. For each aberrometer and each eye, the averaged Zernike data were used to calculate various root-mean-square (RMS) data. These parameters, together with the refractive parameters, were then analyzed and complimented by paired t-tests. RESULTS: At a pupil diameter of 4 mm, the number of total aberrations in the entire eye showed significant differences for the mean values of spherical aberrations (Z4,0) obtained with the OPD Scan and iTrace aberrometers (p=0.001). Aberrations of the internal optics showed significant differences in the mean values of total RMS, coma (Z3,-1), and trefoil (Z3,3) between the iTrace and OPD Scan (p<0.001, p=0.01, p<0.001) for the same pupil diameter of 4 mm. At a pupil diameter of 6 mm, the two instruments showed a similar number of total aberrations. Aberrations of the internal optics showed significant differences in the mean values of total RMS, spherical aberration (Z4,0), and coma (Z3,-1) between the two devices (p<0.001, p=0.01, p<0.001). CONCLUSIONS: The iTrace and OPD Scan showed the largest number of differences for aberrations of internal optics rather than total aberrations for both pupil diameters. These results suggest that in healthy eyes, the two aberrometers may vary in some details. The aberrometers showed more agreement at a pupil diameter of 6 mm compared to 4 mmope

    Factors influencing mothers’ intention to vaccinate their elementary school sons against human papillomavirus

    Get PDF
    Purpose The purpose of this study was to identify the factors influencing mothers’ intention to vaccinate their elementary-school sons against human papillomavirus (HPV). Methods The participants were 151 mothers of fourth- to sixth-grade boys at three elementary schools in Daejeon, Korea. The data were analyzed using SPSS for Windows version 25.0. Descriptive statistics, the independent t-test, one-way analysis of variance, the Mann–Whitney U test, Pearson correlation coefficients, and multiple regression analysis were used. Results The mothers’ score for intention to vaccinate their sons against HPV was 5.04 out of 7. Self-efficacy (β=.60, p<.001) and subjective norms towards HPV vaccination (β=.30, p<.001) were significant factors influencing mothers’ intention to vaccinate their elementary-school sons against HPV. These factors accounted for 81.0% of HPV vaccination intention among mothers (F=160.84, p<.001). Conclusion The results of this study suggest that to increase the HPV vaccination rate for elementary-school boys, it is necessary to develop intervention strategies to improve mothers’ self-efficacy and subjective norms towards HPV vaccination and to verify the effects of those strategies. This research provides a foundation for designing interventions to increase the HPV vaccination rate of elementary-school boys

    Visual outcomes and safety after bilateral implantation of a trifocal presbyopia correcting intraocular lens in a Korean population: a prospective single-arm study

    Get PDF
    Abstract Background To investigate the 3-month postoperative performance and safety after implantation of a trifocal intraocular lens (IOL) in a Korean population. Methods This was a clinical, prospective, multicenter, single-arm study. Forty-four subjects (88 eyes) with bilateral cataract with expected postoperative corneal astigmatism of < 1.00 diopter (D) and no ocular disease or eye condition underwent bilateral implantation of the AcrySof IQ® PanOptix IOL (TFNT00). Postoperative examination at 3 months included binocular defocus curve; binocular best corrected distance visual acuity (BCDVA); monocular/binocular uncorrected VA (UCVA) at distance (4 m), intermediate (60 cm), and near (40 cm); contrast sensitivity under photopic conditions with/without glare; and subjective outcomes, including satisfaction and spectacle independence. Results Binocular defocus curve at 3 months after bilateral implantation showed VA of 0.1 logMAR or better from + 0.5 D through − 2.5 D. Binocular BCDVA mean ± SD at 4 m was − 0.05 ± 0.07 logMAR. Binocular and monocular UCVA was 0.03 ± 0.1 and 0.08 ± 0.12 logMAR (4 m), − 0.00 ± 0.11 and 0.05 ± 0.13 logMAR (60 cm), and 0.03 ± 0.12 and 0.09 ± 0.13 logMAR (40 cm), respectively. Contrast sensitivity with glare was 1.67 ± 0.13, 1.91 ± 0.17, 1.54 ± 0.21, and 1.14 ± 0.20 log units at 3, 6, 12, and 18 cycles/degree, respectively. At near and intermediate distances, 84 and 77% of subjects reported good/excellent satisfaction, and 84 and 91% of subjects reported spectacle independence, respectively. Conclusions In a Korean population, visual performance of the trifocal TFNT00 IOL 3 months postoperatively was < 0.1 logMAR for binocular UCVA at all distances, with high subject satisfaction and spectacle independence. Trial registration www.ClinicalTrials.gov ( NCT03268746 ). Registered August 31, 2017