4,050 research outputs found

    Phenotypic and genotypic resistance to colistin in E. coli isolated from wild boar (Sus scrofa) hunted in Italy

    Get PDF
    The One Health approach is not only focused on diseases and zoonosis control but also on antimicrobial resistance. As concern this important issue, the problem of plasmid-mediated colistin resistance recently emerged. Few studies reported data about colistin resistance and mcr genes in bacteria from wildlife. In this manuscript, 168 Escherichia coli isolated from hunted wild boar were tested; colistin resistance was evaluated by MIC microdilution method, and the presence of mcr-1 and mcr-2 genes was evaluated by PCR. Overall, 27.9% of isolates resulted resistant to colistin, and most of them showed a MIC value > 256 μg/mL. A percentage of 44.6% of tested E. coli scored positive for one or both genes. In details, 13.6% of isolated harbored mcr-1 and mcr-2 in combination; most of them exhibiting the highest MIC values. Interestingly, 19.6% of mcr-positive E. coli resulted phenotypically susceptible to colistin. Wild boar could be considered a potential reservoir of colistin-resistant bacteria. In the light of the possible contacts with domestic animals and humans, this wild species could play an important role in the diffusion of colistin resistance. Thus, the monitoring programs on wildlife should include this aspect

    Evaluation of different methods to estimate the transfer of immunity in donkey foals fed with colostrum of good IgG quality: A preliminary study

    Get PDF
    The aims of the present study were to evaluate the correlation between IgG Serum Radial Immunodiffusion (SRID), Electrophoresis Gamma Globulins (EGG), Electrophoresis Total Protein (ETP) and the serum total protein (TP) analyzed by refractometry and by a dry chemistry analyzer (Biuret) and to estimate serum IgG concentrations using serum TP. A total of 36 samples collected at four different times (birth, 6, 12, 24 hours after birth) from nine Amiata donkey foals were evaluated with SRID, EGG, ETP, serum TP Biuret and refractometry. SRID IgG concentration increased significantly over time until T12. Serum TP analyzed with refractometry, electrophoresis and Biuret showed a statistically significant difference between T0 and T6 vs T12 and T24. A good or strong correlation was found between different tests performed. Equations to quantify serum IgG were created and can be used for estimating the donkey foals’ serum IgG in the first day of life. Serum TP refractometry showed a high correlation with SRID IgG (0.91) which may be a particularly useful and economic instrument to estimate the transfer of immunity in donkey foals during the first day of life

    Mammary cistern size during the dry period in healthy dairy cows: A preliminary study for an ultrasonographic evaluation

    Get PDF
    We evaluated the udder cistern (UC) size during the dry period using ultrasound. Forty healthy quarters were evaluated in both the longitudinal and cross-section of the UC. Quarters were evaluated at the drying-off (T0) and 24 h later (T1), then regularly until the end of the dry period (T7–T58), during the colostrum production phase (TCPP) and at 7 days in milking (T7PP). The Spearman test was applied to find the correlation between the ultrasonographic UC size (UUCS) assessment and time. The Friedman test and Dunn’s test for multiple comparisons as a post-hoc test were performed to compare the forequarter and hindquarter cross-sections (FQCSs and HQCSs, respectively) and the forequarter and hindquarter longitudinal sections (FQLSs and HQLSs, respectively) at T0 vs. T58 vs. TCPP vs. T7PP. A total of 440 images were evaluated. A negative linear correlation between time and FQCS and FQLS (r = −0.95; p < 0.0004) and between time and HQCS and HQLS (r = −0.90; p < 0.002) was found. The UUCS decreased throughout the dry period, starting to increase at the beginning of the next lactation. Measuring the UUCS provides useful information for monitoring the dry period

    Evaluation of jennies' colostrum: IgG concentrations and absorption in the donkey foals. A preliminary study

    Get PDF
    Immunoglobulin type G (IgG) concentration both in jennies' colostrum and in serum of donkey foals are mostly unknown in the first 24 h after delivery. The aims of the present study were to evaluate the IgG concentrations of colostrum during the first 24 h of lactation of Amiata jennies, the absorption of colostrum and the weekly body weight gain of the donkey foals. IgG concentrations were assessed in the jennies' colostrum and in the serum of donkey foals. Colostrum was collected in 9 jennies ready after delivery, and at 6, 12, 24 h after foaling from both halves. Serum was collected at the same sampling times from 9 donkey foals. Donkey foals were weighted at birth and then weekly until the 28th days of life. Temporal changes of IgG concentrations in dam's colostrum and in donkey foal serum were analyzed by a linear regression model and a general linear model, respectively. Results showed that colostrum IgG concentration were similar between the left and the right half. Colostrum IgG concentrations decreased continuously throughout the time in all jennies by 0.0244 Log10 mg/mL per hour. Serum IgG concentrations in donkey foals at birth was significantly lower compared to other times. No correlation was found between the colostrum IgG concentrations and the average weekly body weight gain of the donkey foal. The pattern of colostrum IgG levels in jennies and serum IgG concentration in donkey foals seem to be similar to what reported for equine. However, the donkey foals seem to be less agammaglobulinemic at birth compared to the horse foal. The pattern and both serum and colostrum concentrations evaluated in the Amiata donkeys were slightly different from results reported in other donkey breeds, underlying the importance of setting references specific to breed

    Timing performance of a double layer diamond detector

    Get PDF
    In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This work describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement larger than a factor of 1.6-1.7 for the timing precision of the measurement when compared to a one layer scCVD diamond detector.Peer reviewe

    Presence and characterization of zoonotic bacterial pathogens in wild boar hunting dogs (Canis lupus familiaris) in tuscany (italy)

    Get PDF
    Domestic dogs (Canis lupus familiaris) used for wild boar (Sus scrofa) hunting may represent incidental hosts for several zoonotic pathogens. This investigation aimed to evaluate the presence of anti-Leptospira antibodies and the occurrence, antimicrobial resistance, and virulence of Salmonella spp., Yersinia enterocolitica, and Listeria monocytogenes in sera and rectal swabs collected from 42 domestic hunting dogs in the Tuscany region (Italy). Regarding Leptospira, 31 out of 42 serum samples (73.8%) were positive and serogroup Pomona was the most detected (71.4%) at titers between 1:100 and 1:400. Four Salmonella isolates (9.52%) were obtained, all belonging to serotype Infantis; two of them showed antimicrobial resistance to streptomycin, while pipB and sopE presence was assessed in all but one isolate. Concerning Yersinia enterocolitica, seven isolates (16.7%) were obtained, six belonging to biotype 1 and one to biotype 4. Resistance to amoxicillin–clavulanic acid, cephalothin, and ampicillin was detected. Biotype 4 presented three of the virulence genes searched (ystA, ystB, inv), while isolates of biotype 1 showed only one gene. No Listeria monocytogenes was isolated from dog rectal swabs. The results suggest that hunting dogs are exposed to different bacterial zoonotic agents, potentially linked to their work activity, and highlight the possible health risks for humans

    Test of Ultra Fast Silicon Detectors for the TOTEM upgrade project

    Get PDF
    This paper describes the performance of a prototype timing detector, based on 50 mu m thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and bias voltage is investigated in this paper. A timing precision from 30 ps to 100 ps (RMS), depending on the pixel capacitance, has been measured at a bias voltage of 180 V.Peer reviewe

    A novel background reduction strategy for high level triggers and processing in gamma-ray Cherenkov detectors

    Full text link
    Gamma ray astronomy is now at the leading edge for studies related both to fundamental physics and astrophysics. The sensitivity of gamma detectors is limited by the huge amount of background, constituted by hadronic cosmic rays (typically two to three orders of magnitude more than the signal) and by the accidental background in the detectors. By using the information on the temporal evolution of the Cherenkov light, the background can be reduced. We will present here the results obtained within the MAGIC experiment using a new technique for the reduction of the background. Particle showers produced by gamma rays show a different temporal distribution with respect to showers produced by hadrons; the background due to accidental counts shows no dependence on time. Such novel strategy can increase the sensitivity of present instruments.Comment: 4 pages, 3 figures, Proc. of the 9th Int. Syposium "Frontiers of Fundamental and Computational Physics" (FFP9), (AIP, Melville, New York, 2008, in press

    Diamond Detectors for the TOTEM Timing Upgrade

    Full text link
    This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.Comment: 26 pages, 18 figures, 2 tables, submitted for publication to JINS

    LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment

    Full text link
    Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.Comment: 20 pages, 11 figures, 5 figures, to be submitted to New J. Phy
    corecore