35 research outputs found

    Surgical site infections in orthopaedic trauma

    No full text

    Incidence and risk factors for the development of arthrosis after traumatic elbow injuries

    No full text

    Quantitative three-dimensional computed tomography measurement of radial head fractures

    No full text

    Monteggia Fracture Types

    No full text

    Inter-observer variation in the diagnosis of coronal articular fracture lines in the lunate facet of the distal radius

    Full text link
    Background: Several studies support the use of CT for diagnosing coronal fractures of the distal radius but the inter-observer reliability of these observations is less well studied. We tested the null hypothesis that radiographs alone and the combination of radiographs and two-dimensional computed tomography scans (2DCT) have the same inter-observer variation for the diagnosis of coronal articular fracture lines in the distal radius. Methods: Using a web-based survey, 63 surgeons were randomized to evaluate 16 fractures of the distal radius on radiographs alone or radiographs and 2DCT for the presence or absence of a coronal fracture line of the lunate facet and, if present, the stability of the fracture. The kappa multirater measure was calculated to estimate agreement between observers. Results: The inter-observer variation in diagnosis of a coronal fracture line was fair with both radiographs and 2DCT, as was the diagnosis of instability of the volar lunate facet fracture when present. Conclusion: Two-dimensional computed tomography does not improve observer agreement on the diagnosis of coronal plane articular fracture lines in the lunate facet of the distal radius. © 2012 American Association for Hand Surgery

    Interobserver Variability in the Treatment of Little Finger Metacarpal Neck Fractures

    Full text link
    Purpose To address the null hypothesis that surgeons shown radiographs of little finger metacarpal neck fractures with measured fracture angulation would recommend surgery as often as surgeons shown unmarked radiographs. Methods Members of the Science of Variation Group, an international collaboration of fully trained orthopedic and trauma surgeons, were asked to review 20 little finger metacarpal neck fracture cases, which included a vignette and 3 high-quality radiographs. Members were then randomized to review radiographs with or without measured fracture angulation on the lateral view and select operative or nonoperative management. Results Surgeons shown radiographs with measured angulation were more likely to recommend surgery, and there was less variability among these surgeons, particularly for fractures with less angular deformity. Conclusions Measured fracture angulation has a small but significant influence on treatment recommendations for little finger metacarpal neck fractures
    corecore