111 research outputs found

    Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Finite element analysis results will show significant differences if the model used is performed under various material properties, geometries, loading modes or other conditions. This study adopted an FE model, taking into account the possible asymmetry inherently existing in the spine with respect to the sagittal plane, with a more geometrically realistic outline to analyze and compare the biomechanical behaviour of the lumbar spine with regard to the facet force and intradiscal pressure, which are associated with low back pain symptoms and other spinal disorders. Dealing carefully with the contact surfaces of the facet joints at various levels of the lumbar spine can potentially help us further ascertain physiological behaviour concerning the frictional effects of facet joints under separate loadings or the responses to the compressive loads in the discs.</p> <p>Methods</p> <p>A lumbar spine model was constructed from processes including smoothing the bony outline of each scan image, stacking the boundary lines into a smooth surface model, and subsequent further processing in order to conform with the purpose of effective finite element analysis performance. For simplicity, most spinal components were modelled as isotropic and linear materials with the exception of spinal ligaments (bilinear). The contact behaviour of the facet joints and changes of the intradiscal pressure with different postures were analyzed.</p> <p>Results</p> <p>The results revealed that asymmetric responses of the facet joint forces exist in various postures and that such effect is amplified with larger loadings. In axial rotation, the facet joint forces were relatively larger in the contralateral facet joints than in the ipsilateral ones at the same level. Although the effect of the preloads on facet joint forces was not apparent, intradiscal pressure did increase with preload, and its magnitude increased more markedly in flexion than in extension and axial rotation.</p> <p>Conclusions</p> <p>Disc pressures showed a significant increase with preload and changed more noticeably in flexion than in extension or in axial rotation. Compared with the applied preloads, the postures played a more important role, especially in axial rotation; the facet joint forces were increased in the contralateral facet joints as compared to the ipsilateral ones at the same level of the lumbar spine.</p

    STAT5 Induces Androgen Receptor (AR) Gene Transcription in Prostate Cancer and Offers a Druggable Pathway to Target AR Signaling

    Get PDF
    Androgen receptor (AR) drives prostate cancer (PC) growth and progression, and targeting AR signaling is the mainstay of pharmacological therapies for PC. Resistance develops relatively fast as a result of refueled AR activity. A major gap in the field is the lack of understanding of targetable mechanisms that induce persistent AR expression in castrate-resistant PC (CRPC). This study uncovers an unexpected function of active Stat5 signaling, a known promoter of PC growth and clinical progression, as a potent inducer of AR gene transcription. Stat5 suppression inhibited AR gene transcription in preclinical PC models and reduced the levels of wild-type, mutated, and truncated AR proteins. Pharmacological Stat5 inhibition by a specific small-molecule Stat5 inhibitor down-regulated Stat5-inducible genes as well as AR and AR-regulated genes and suppressed PC growth. This work introduces the concept of Stat5 as an inducer of AR gene transcription in PC. Pharmacological Stat5 inhibitors may represent a new strategy for suppressing AR and CRPC growth

    Numerical Simulation of Asymmetrically Altered Growth as Initiation Mechanism of Scoliosis

    Get PDF
    The causes of idiopathic scoliosis are still uncertain; buckling is mentioned often, but never proven. The authors hypothesize another option: unilateral postponement of growth of MM Rotatores or of ligamentum flavum and intertransverse ligament. In this paper, both buckling and the two new theories of scoliotic initiation are studied using a new finite element model that simulates the mechanical behavior of the human spine. This model was validated by the stiffness data of Panjabi et al. (J. Biomech. 9:185–192, 1976). After a small correction of the prestrain of some ligaments and the MM Rotatores the model appeared to be valid. The postponement in growth was translated in the numerical model in an asymmetrical stiffness. The spine was loaded axially and the resulting deformation was analyzed for the presence of the coupling of lateral deviation and axial rotation that is characteristic for scoliosis. Only unilateral postponement of growth of ligamentum flavum and intertransverse ligament appeared to initiate scoliosis. Buckling did not initiate scoliosis

    Results of a multi-centric, prospective, randomized, controlled study

    No full text

    Radiographic evaluation of cervical spine segment settling characteristics in the presence of an anterior dynamic cervical plate

    No full text

    Registerbasierte Auswertung nosokomialer Wundinfekte für Spondylodesen aus dem Jahr 2014

    No full text

    Complications and management of complications in surgical treatment of pediatric spine tumors: 10 years experience

    No full text

    Chirurgische Therapie sekundärer spinaler Tumore: Überraschende Ergebnisse

    No full text
    corecore