18 research outputs found

    The FIRST large-scale mapping of radon concentration in soil gas and water in Romania

    Get PDF
    In the framework of the last Council Directive 2013/59 (Euratom, 2014) laying down basic safety standards for protection against the dangers arising from exposure to ionizing radiation, the problem of radon was assumed in Romania at national level by responsible authorities through the design and development of a National Radon Action Plan and an adequate legislation (HG nr. 526/2018). In order to identify radon risk areas, however, it is necessary to perform systematic radon measurements in different environmental media (soil gas, water, indoor air) and to map the results. This paper presents an atlas of up-to-date radon in soil and water levels for central and western part of Romania. The radon in soil map includes data from 2564 measurements carried out on-site, using Luk3C radon detector. The Luk-VR system was used to measure radon activity concentration from 2452 samples of drinking water. The average radon activity concentration was 29.3?kBq?m-3 for soil gas, respectively 9.8?Bq?l-1 for water dissolved air. Mapping of radon can be a useful tool to implement radon policies at both the national and local levels, defining priority areas for further study when land-use decisions must be made.This work was supported by the Romanian National Authority for Scientific Research and Innovation, CNCS-UEFISCDI, by the project ”Radon map (residential, geogenic, water) for center, west and north-west regions from Romania (RAMARO), PN-II-PCCA-PT-73/2012 and by the project ID P_37_229, Contract No. 22/01.09.2016, with the title „Smart Systems for Public Safety through Control and Mitigation of Residential Radon linked with Energy Efficiency Optimization of Buildings in Romanian Major Urban Agglomerations SMARTRAD-EN” of the POC Programme

    A new approach to radon temporal correction factor based on active environmental monitoring devices

    Get PDF
    The present study aims to identify novel means of increasing the accuracy of the estimated annual indoor radon concentration based on the application of temporal correction factors to short-term radon measurements. The necessity of accurate and more reliable temporal correction factors is in high demand, in the present age of speed. In this sense, radon measurements were continuously carried out, using a newly developed smart device accompanied by CR-39 detectors, for one full year, in 71 residential buildings located in 5 Romanian cities. The coefficient of variation for the temporal correction factors calculated for combinations between the start month and the duration of the measurement presented a low value (less than 10%) for measurements longer than 7 months, while a variability close to 20% can be reached by measurements of up to 4 months. Results obtained by generalized estimating equations indicate that average temporal correction factors are positively associated with CO2 ratio, as well as the interaction between this parameter and the month in which the measurement took place. The impact of the indoor-outdoor temperature differences was statistically insignificant. The obtained results could represent a reference point in the elaboration of new strategies for calculating the temporal correction factors and, consequently, the reduction of the uncertainties related to the estimation of the annual indoor radon concentration.Acknowledgements: The research is supported by the project ID P_37_229, Contract No. 22/01.09.2016, with the title, Smart Systems for Public Safety through Control and Mitigation of Residential Radon linked with Energy Efficiency Optimization of Buildings in Romanian Major Urban Agglomerations SMART-RAD-EN” of the POC Programme

    An Innovative System for Monitoring Radon and Indoor Air Quality

    Get PDF
    Nowadays, a global trend towards increasing the performance of a building is the reduction in energy consumption. In this respect, for existing residential buildings the most common techniques are the application of a thermal insulation layer to the exterior wall of the building and / or window replacements. Unfortunately, their application without proper education of those involved may have a negative effect on the indoor air quality. The use of a continuous monitoring device can give the owner the ability to understand the impact of his behaviour on indoor air quality and, as such, to adjust his routine in order to maintain the indoor air quality at the desired level. This paper introduces a prototype, called ICA system, for continuous, real-time indoor air quality monitoring. The ICA system presents sensors for monitoring the concentration of radon, CO2, CO, VOCs, as well as meteorological parameters, such as temperature, pressure, and relative humidity. Experiments were performed both in laboratory and in situ conditions for testing and validating the proposed system.This work was supported by the project ID P_37_229, Contract No. 22/01.09.2016, with the title “Smart Systems for Public Safety through Control and Mitigation of Residential Radon linked with Energy Efficiency Optimization of Buildings in Romanian Major Urban Agglomerations SMART-RAD-EN” of the POC Programme

    Cave spiders choose optimal environmental factors with respect to the generated entropy when laying their cocoon

    Get PDF
    The choice of a suitable area to spiders where to lay eggs is promoted in terms of Darwinian fitness. Despite its importance, the underlying factors behind this key decision are generally poorly understood. Here, we designed a multidisciplinary study based both on in-field data and laboratory experiments focusing on the European cave spider Meta menardi (Araneae, Tetragnathidae) and aiming at understanding the selective forces driving the female in the choice of the depositional area. Our in-field data analysis demonstrated a major role of air velocity and distance from the cave entrance within a particular cave in driving the female choice. This has been interpreted using a model based on the Entropy Generation Minimization - EGM - method, without invoking best fit parameters and thanks to independent lab experiments, thus demonstrating that the female chooses the depositional area according to minimal level of thermo-fluid-dynamic irreversibility. This methodology may pave the way to a novel approach in understanding evolutionary strategies for other living organisms

    Radon Levels in Romanian Caves: An Occupational Exposure Survey

    No full text
    A comprehensive radon survey has been carried out in seven caves located in the western half of Romania’s most significant karst regions. Touristic and non-touristic caves were investigated with the aim to provide a reliable distribution of their radon levels and evaluate the occupational exposure and associated effective doses. Radon gas concentrations were measured with long-term diffusion-type detectors during two consecutive seasons (warm and cold). All investigated caves exceed the European Union reference level of radon gas at workplaces (300 Bq/m3). The radon concentration in these caves ranges between 53 and 2866 Bq/m3, reflecting particular cave topography, season-related cave ventilation, and complex tectonic and geological settings surrounding each location. Relatively homogeneous high radon levels occur in all investigated touristic caves and in Tăuşoare and Vântului along their main galleries. Except for Muierii, in all the other caves radon levels are higher during the warm season, compared to the cold one. This suggests that natural cave ventilation largely controls the underground accumulation of radon. The results reported here reveal that the occupational exposure in Urşilor, Vadu Crişului, Tăuşoare, Vântului, and Muierii caves needs to be carefully monitored. The effective doses to workers vary between an average of 0.25 and 4.39 mSv/year depending on the measuring season. The highest values were recorded in show caves, ranging from 1.15 to 6.15 mSv/year, well above the European recommended limit, thus posing a potential health hazard upon cave guides, cavers, and scientists
    corecore