256 research outputs found

    Single photon nonlinearities using arrays of cold polar molecules

    Full text link
    We model single photon nonlinearities resulting from the dipole-dipole interactions of cold polar molecules. We propose utilizing ``dark state polaritons'' to effectively couple photon and molecular states; through this framework, coherent control of the nonlinearity can be expressed and potentially used in an optical quantum computation architecture. Due to the dipole-dipole interaction the photons pick up a measurable nonlinear phase even in the single photon regime. A manifold of protected symmetric eigenstates is used as basis. Depending on the implementation, major sources of decoherence result from non-symmetric interactions and phonon dispersion. We discuss the strength of the nonlinearity per photon and the feasibility of this system.Comment: 8 pages, 9 figures Accepted for publication in Physical Review

    Cluster state generation using van der Waals and dipole-dipole interactions in optical lattices

    Full text link
    We present a scalable method for generation of a cluster state for measurement-based quantum computing using van der Waals or dipole-dipole interactions between neutral atoms or polar molecules in an optical lattice. Nearest neighbor entanglement is accomplished by performing a phase gate using interaction of atoms in Rydberg states or molecules in large dipole moment states. All nearest neighbors are sequentially entangled in a finite number of operations, independent of the number of qubits, producing a 1D cluster state. A universal 2D cluster state can be generated in several ms in a two-dimensional optical lattice by producing a series of 1D cluster states in one lattice direction, followed by application of the entangling operations in another lattice direction. We discuss the viability of the scheme with Rb Rydberg atoms.Comment: Revised and expanded versio

    Analysis of polyethylene wear in plain radiographs: The number of radiographs influences the results

    Get PDF
    Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs

    Mechanical properties during healing of Achilles tendon ruptures to predict final outcome: A pilot Roentgen stereophotogrammetric analysis in 10 patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are presently few methods described for in vivo monitoring of the mechanics of healing human tendon ruptures, and no methods for prediction of clinical outcome. We tested if Roentgen stereophotogrammetric analysis (RSA) can be used to follow the restoration of mechanical properties during healing of ruptured Achilles tendons, and if early measurements can predict clinical results.</p> <p>Methods</p> <p>Achilles tendon repair was studied with RSA in 10 patients with a total rupture. Tantalum beads were implanted in conjunction with surgical repair. The patients were evaluated at 6, 12 and 18 weeks, and after 1 year. RSA was performed with two different mechanical loadings, and the strain induced by increasing load was measured. The transverse area was determined by ultrasound. CT scan at 12 weeks confirmed that the tantalum beads were located within the tendons. Functional testing was done after 1 year. A heel raise index was chosen as primary clinical outcome variable.</p> <p>Results</p> <p>The strain was median 0.90, 0.32 and 0.14 percent per 100 N tendon force at 6 weeks, 18 weeks and one year respectively. The error of measurement was 0.04 percent units at 18 weeks. There was a large variation between patients, which appears to reflect biological variation. From 6 to 18 weeks, there was a negative correlation between increase in transverse area and increase in material properties, suggesting that healing is regulated at the organ level, to maximize stiffness. Modulus of elasticity during this time correlated with a heel raise index at one year (Rho = 0.76; p = 0.02).</p> <p>Conclusion</p> <p>We conclude that the RSA method might have potential for comparing different treatments of Achilles tendon ruptures.</p

    The Elite-Plus stem migrates more than the flanged Charnley stem: A clinical, radiographic, and radiostereometric analysis of 114 patients with an average of 7 years follow-up

    Get PDF
    Background and purpose The Charnley Elite-Plus stem was introduced in 1993 as a presumed improvement of the flanged Charnley stem. We started this study in 1996 to investigate the migratory pattern of the Elite-Plus stem. Patients and methods We followed 114 patients with osteoarthritis and a primary total hip replacement with the Elite-Plus stem. Mean age at the time of operation was 64 (50-76) years. The mean follow-up time was 6.5 (2-7) years. Radiographs were evaluated with respect to cementing technique, migration, and wear measured by radiostereometry (RSA). Results The stem survival was 98% (CI: 96-100) at 7 years and 92% (CI: 86-97) at 10 years. Mean migration of the femoral head was 0.35 mm (SD 0.3) medially, 0.51 mm (SD 0.6) distally, and 1.1 mm (SD 1.8) in the dorsal direction. Mean total point motion was 1.7 mm (SD 1.7). The migration of the stems stabilized after 5 years in the medial and dorsal directions, but continued to subside slightly. Migration along any of the axes was higher if the cementing technique was inferior. Interpretation Patients with a Charnley Elite-Plus stem and defects in the cement mantle or other signs of inferior implantation technique should be carefully monitored

    A Mi\u27kmaq First Nation cosmology: investigating the practice of contemporary Aboriginal Traditional Medicine in dialogue with counselling – toward an Indigenous therapeutics

    Get PDF
    This paper explores from a Mi’kmaq and Aboriginal standpoint foundational knowledge in Indigenous therapeutics. Based on an eco-social-psycho-spiritual way of working, the article proposes Indigenous cultural models that open a window to a rich cultural repository of meanings associated with Indigenous cosmology, ontology and epistemology. The three layers of meaning, theory and practice within the symbolic ‘Medicine Lodge’ or ‘Place of The Dreaming’ give rise to ways of working that are deeply integrative and wholistic. These forms of Indigenous theory and practice have much to offer the counselling and complimentary health professions

    Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

    Get PDF
    BACKGROUND: Proximal femoral bone loss during revision hip arthroplasty often requires bypassing the deficient metaphyseal bone to obtain distal fixation. The purpose of this study was to determine the effect of stem diameter and length of diaphyseal contact in achieving rotational stability in revision total hip arthroplasty. METHODS: Twenty-four cadaveric femoral specimens were implanted with a fully porous-coated stem. Two different diameters were tested and the stems were implanted at multiple contact lengths without proximal bone support. Each specimen underwent torsional testing to failure and rotational micromotion was measured at the implant-bone interface. RESULTS: The larger stem diameter demonstrated a greater torsional stability for a given length of cortical contact (p ≤ 0.05). Decreasing length of diaphyseal contact length was associated with less torsional stability. Torsional resistance was inconsistent at 2 cm of depth. CONCLUSION: Larger stem diameters frequently used in revisions may be associated with less diaphyseal contact length to achieve equivalent rotational stability compared to smaller diameter stems. Furthermore, a minimum of 3 cm or 4 cm of diaphyseal contact with a porous-coated stem should be achieved in proximal femoral bone deficiency and will likely be dependent on the stem diameter utilized at the time of surgery
    • …
    corecore